La description
Basic features:     1, the simulator
built-in high-capacity lithium battery, can work long hours; fully
charged can work more than *0 hours (the factory). Because it is a
lithium battery, please try not to over discharge. Please note that
the proper use of the charger, the charger voltage can not be
higher than 4.2V.     2, using *0 universal
adapter for ECG, ECG machine and can be used with a variety of
monitors of lead wires to connect.     3,
the charger green light indicates charging is completed, the more
red light indicates that power is low.
    4, increase the low battery auto
shutdown features to protect the lithium battery. Instructions for
use: The simulator can produce the following waveforms, the first
code represents the waveform as follows:
        1, the
normal ECG waveform
        2, positive
and negative triangular waveform
        3,
arrhythmia triangular waveform simulation
        4, square
wave, square wave measurement using scanning speed
        5, sine
wave, amplitude-frequency characteristic measurement
        6,
simulated respiratory waveform
        7,
simulated fetal heartbeat (to use an external tooling) Note:
       1, the simulator
automatically generated after power waveform a normal ECG waveform.
       2, the simulator
LED display tubes, when there is no operation within *4 hours of
s, it will automatically turn off the display, stop work in
order to save power. Key Description
       A total of four
s, followed by selection keys to increase the key, down key,
the Enter key, in addition to a set of key combinations Select
:       This is
used to select the parameter to be changed, a total of four LED
tubes to display the four codes represent the content displayed
      A code representing the
waveform ,**4 represents a parameter to change (2 is the value one
hundred, three on behalf of ten, four representatives bits)
      ED tube right lower leg
of the highlights, which means that now the selected content; can
be changed. Increase key: When using the Select to select a
good to change the content, use this key parameter changes.
Decrease key: When using the Select to select a good to
change the content, use this key parameter changes. Enter key: When
the parameter change is completed, this will confirm to
confirm changes to the parameters and generate the corresponding
waveform. Key combinations: Press the Select key, and then press
the Enter key, release the Enter key, release the Select key, then
select a key combination represents, press the Enter key will
display different content. Instructions say to use the various
waveforms, respectively, the method of operation: A normal ECG
waveform:      ★ heart rate setting
range :*****0bpm; (initial value: *0 bpm)
     ★ signal amplitude fixed. 2,
positive and negative triangular waveforms:
     ★ Frequency range :*****0bpm;
(initial value: *5 bpm)      ★
amplitude range :0.**4Mv (*0:0.1 mV, **0:4 mV);
     ★ 2 modes, Mode 1: positive
waveform Mode 2: Negative waveform; through a combination of keys.
3, arrhythmia waveforms:      ★
Frequency range :*****0bpm; (initial value: *0 bpm)
     ★ amplitude range :0.**4Mv
(*0:0.1 mV, **0:4 mV);      ★ 2
modes, Mode 1: the next big wave, Mode 2: Big wave on top. Through
a combination of keys. 4, square wave:
     ★ Frequency range: 0.1Hz**0Hz
(*0:0.1 Hz **0:*0 Hz); (Initial value: 1 Hz)
     ★ amplitude range :0.**4Mv
(*0:0.1 mV, **0:4 mV); 5, sine wave:
     ★ Frequency range :****0Hz;
(initial value: *0 Hz)      ★
amplitude range :0.**4Mv (*0:0.1 mV, **0:4 mV);
     ★ superimposed on the waveform
DC component, the range is 0.1mV*3mV (*0:0.1 mV, **0:4 mV);
     ★ Through the combination of
keys, select the need to change the parameters, Mode 1: Frequency;
Mode 2: DC component superimposed
    (*0:0.1 mV, **0:4 mV); 6, simulated
breathing waveforms:      ★
Frequency range :*****0 beats / min. (Initial value: *0 bpm); ★
Please note that at this time ignored ECG; 7, simulated fetal heart
rate (extensions):      ★ Frequency
range :*****0bpm; (initial value: **0 bpm); 8, the signal amplitude
settings:      ★ amplitude range:
0.1mV*4mV (*0:0.1 mV, **0:4 mV); (initial value: **0)
     ★ Please note that this
setting will affect the amplitude of ECG waveforms, in addition to
all waveforms.
Pays: |
China |
N ° de modèle: |
SKX-2000D
|
Prix FOB: |
120 / Unit (Negotiable)
Obtenir le dernier prix
|
Localité: |
Xuzhou, Jiangsu, China |
Prix de commande minimale: |
120 per Unit |
Commande minimale: |
1 Unit |
Packaging Detail: |
Bubble wrap drop resistance |
Heure de livraison: |
1-2 days can be shipped |
Capacité de Fournir: |
289 Unit per Week |
Payment Type: |
Western Union |
Groupe de produits : |
ECG monitoring equipment category
|