Prix FOB
Obtenir le dernier prix190 USD / Unit
|1 Unit Minimum Order
Pays:
China
N ° de modèle:
SKX-1000B
Prix FOB:
190 USD / Unit Obtenir le dernier prix
Localité:
Xuzhou, Jiangsu, China
Prix de commande minimale:
190 per Unit
Commande minimale:
1 Unit
Packaging Detail:
Bubble wrap drop resistance
Heure de livraison:
1-2 days can be shipped
Capacité de Fournir:
198 Unit per Week
Payment Type:
Western Union
Groupe de produits :
China
Personne àcontacter Ms. zhouxuemei
xu zhou shi jianghaibuxiugangcheng 4haolou208, Xuzhou, Jiangsu
Basic features:    1, the oxygen probe detector built-in high-capacity lithium battery, can work long hours; fully charged can work more than *0 hours (the factory). Because it is a lithium battery, please try not to over discharge. Please note that the proper use of the charger, the charger voltage can not be higher than 4.2V.     2, the use of digital tube display content.     3, the charger green light indicates charging is completed, the more red light indicates that power is low.     4, the current can be detected launch tube 2 feet BCI probe     5, more features continue to upgrade     6, more than SKX****0A-type detection function more  Operation and code description Detector test after boot shows "***-" to enter standby mode. Select the "five core" is carried out five core probe detection Select the "six-core" is a six-core probe detection              When starting the test, the message "...." means being detected, please wait for test results After detection is complete, if the probe is completely normal, it shows "good", When an error is detected, the display with "E" at the beginning of an error code Priority levels are as follows: The first priority of disconnection Second priority circuit Third priority receiver tube detection The fourth priority transmission pipe detection, IR former RED in the post  Error codes are as follows:  E *1 when the display is disconnected, check the following 1, the probe cable is not connected to Remo head was disconnected 2, Remo head-end connection is normal, but the line in question 3, the probe internal problems  E *2 When the short circuit, check the following 1, is connected to the head of the line if there Remo shorted state 2, Remo head-end connection is normal, but the line in question 3, the probe internal problems  E *3 In this case, check the following 1, the probe's launch tube IR damage 2, the probe's launch tube IR injury, but the brightness diminished  E *4 In this case, check the following 1, the probe's launch tube RED damage 2, the probe's launch tube RED injury, but diminished brightness  E *5 receiver tube or bad, please check the following 1, the probe tube is damaged reception 2, the probe receiving tube aging   E *9 The instrument does not recognize the type of probe
Pays: | China |
N ° de modèle: | SKX-1000B |
Prix FOB: | 190 / Unit Obtenir le dernier prix |
Localité: | Xuzhou, Jiangsu, China |
Prix de commande minimale: | 190 per Unit |
Commande minimale: | 1 Unit |
Packaging Detail: | Bubble wrap drop resistance |
Heure de livraison: | 1-2 days can be shipped |
Capacité de Fournir: | 198 Unit per Week |
Payment Type: | Western Union |
Groupe de produits : | ECG class auxiliary testing equipment |