ECG Simulator or called ECG signal generator By xuzhou mingsheng,
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs.
Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
ECG Simulator or called ECG signal generator
Next

ECG Simulator or called ECG signal generator

483 / Unit

|

1 Unit Minimum Order

Pays:

China

N ° de modèle:

skx-2000sup

Prix FOB:

483 / Unit Obtenir le dernier prix

Localité:

Xuzhou, Jiangsu, China

Prix de commande minimale:

483 per Unit

Commande minimale:

1 Unit

Packaging Detail:

Packing delicate drop resistance

Heure de livraison:

1-2 days can be shipped

Capacité de Fournir:

100 Unit per Week

Payment Type:

Western Union

Contacter maintenant
Membre gratuit

Personne à contacter Ms. zhouxuemei

xu zhou shi jianghaibuxiugangcheng 4haolou208, Xuzhou, Jiangsu

Contacter maintenant

Spécification du produit

  • Xuzhou Ming Sheng Electronic Technology Co., Ltd.:Dongsheng

La description

SKX****0SUP description The waveform type description ( using the PM***0 monitor detection ) 1, waveform code 1: normal ECG waveform The data rate of *0 BPM for *0: code The frequency range of *****0 BPM wave amplitude is fixed, is not affected by the amplitude effect 2, 2: a triangular waveform waveform code Data code for the *5 *5bpm Frequency range: *****0bpm Range 0.**4mV, the amplitude adjustment adjustment. 3, waveform code 3: Fang Bo Data code for the *0 1Hz 0.***0Hz Range 0.**4mV, the amplitude adjustment adjustment. 4, 4: sinusoidal waveform code Data code for the *0 *0Hz ****0Hz Range 0.**4mV, the amplitude adjustment adjustment. 5, the code for the 5:QRS wave waveform You can change the amplitude of T wave, QRS wave amplitude, width of QRS wave, QRS wave frequency To change the parameters through the combination of keys 6, 6: respiratory waveform waveform code Data code for *0bpm Respiratory waveform frequency adjustment range *****0 7, waveform code 7: pacing pulse signal pacing signal of positive and negative direction Data code for *0mS ( 2mS ) The frequency of *0bpm Range is *1.*4mV, the amplitude adjustment adjustment. Through the combination of positive and negative direction switch You can change the pulse width, the range of 0.**2mS 8, waveform code 8: QRS wave front pacing signals Lead pacing signal for positive and negative pulse waveform, through a combination of key switch Lead pacing signal pulse width can be adjusted, the range of 0.**2mS Range is *1.*4mV, the amplitude adjustment adjustment. 9, waveform code 9: adjust the waveform amplitude Data code for the **0 1Mv **0 4Mv *0, waveform code for A: Data code for the 1 *5bpm normal Data code for the 2 **0bpm heartbeat tachycardia Data code for the **5 BPM heartbeat bradycardia Data code for the ***0 BPM T supraventricular heartbeat tachycardia Data code **0 ( *3 ) BPM drain Bo Data code for the **4 BPM agonal rhythm Data code for the *0 BPM arrest *1, the code for the B: Data code for the 1 *5bpm normal Data code for the 2 *2bpm NSR with PAC Data code for the 3 *2bpm rough type of atrial fibrillation, irregular heartbeat 4 *0bpm room early data code 5 *0bpm 2 consecutive ventricular premature data code ( 2 ventricular extrasystole) 6 *0bpm 3 consecutive ventricular premature data code ( multiple ventricular premature ) 7 *0bpm 4 consecutive ventricular premature data code ( multiple ventricular premature ) Data code for the 8 *0bpm premature beats Data code for the 9 *0bpm 2 consecutive beats Data code for the *0 *0bpm 4 consecutive beats s Data code for the *1 *0bpm 1 beats, a normal waveform Data code for the *2 *0bpm all PVCs ( VF / VT ) *2, waveform code for C: Data code for the 1 *0bpm degree block Data code for the 2 *5bpm degree block *5 BPM Data code for the 3 *1bpm degree block *1 BPM Data code for the 4 *0bpm L bnd1 branch block Data code for the 5 *0bpm R bnd1 branch block *3, waveform code for D: Data code 1 ( ****3 ) BPM ATRIAL PAC Data code for the 2 *0bpm pvc1 early Lv focus Data code for the 3 *0bpm pvc1 early Rv focus Data code for the 4 *0bpm nodal PNC Data code for the 5 *0bpm two premature ventricular bigeminy Data code for the 6 *0bpm premature ventricular trigeminy Data code for the 7 *0bpm R ON T

Pays: China
N ° de modèle: skx-2000sup
Prix FOB: 483 / Unit Obtenir le dernier prix
Localité: Xuzhou, Jiangsu, China
Prix de commande minimale: 483 per Unit
Commande minimale: 1 Unit
Packaging Detail: Packing delicate drop resistance
Heure de livraison: 1-2 days can be shipped
Capacité de Fournir: 100 Unit per Week
Payment Type: Western Union
Groupe de produits : ECG monitoring equipment category

Send a direct inquiry to this supplier

To:

Ms. zhouxuemei < xuzhou mingsheng >

Je veux savoir: