ECG signal generator or a patient simulator By xuzhou mingsheng,
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs.
Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
ECG signal generator or a patient simulator
Next

ECG signal generator or a patient simulator

88 / Unit

|

1 Unit Minimum Order

Pays:

China

N ° de modèle:

SKX-2000C

Prix FOB:

88 / Unit Obtenir le dernier prix

Localité:

Xuzhou, Jiangsu, China

Prix de commande minimale:

88 per Unit

Commande minimale:

1 Unit

Packaging Detail:

Bubble wrap drop resistance

Heure de livraison:

1-2 days can be shipped

Capacité de Fournir:

987 Unit per Week

Payment Type:

Western Union

Contacter maintenant
Membre gratuit

Personne à contacter Ms. zhouxuemei

xu zhou shi jianghaibuxiugangcheng 4haolou208, Xuzhou, Jiangsu

Contacter maintenant

Spécification du produit

  • Xuzhou Ming Sheng Electronic Technology Co., Ltd.:Xuzhou Ming Sheng Electronic Technology Co., Ltd.

La description

Basic features:     1, the simulator built-in high-capacity lithium battery, can work long hours; fully charged can work more than *0 hours (the factory). Because it is a lithium battery, please try not to over discharge. Please note that the proper use of the charger, the charger voltage can not be higher than 4.2V.     2, using *0 universal adapter for ECG, ECG machine and can be used with a variety of monitors of lead wires to connect.     3, the charger green light indicates charging is completed, the more red light indicates that power is low.     4, increase the low battery auto shutdown features to protect the lithium battery. Instructions for use: The simulator can produce the following waveforms, the first waveform as a code representing 1, the normal ECG waveform 2, positive and negative triangular waveform Note Note: 1, the simulator automatically generated after power waveform a normal ECG waveform. 2, the simulator LED display tubes, when there is no operation within five seconds, it will automatically turn off the display to save power. Press any to display the trigger again.      Key Description:             A total of four s, followed by selection keys to increase the key, down key, the Enter key, in addition to a set of key combinations            Select :            This is used to select the parameter to be changed, a total of four LED tubes to display the four codes represent the content displayed from left to right,            The first representative waveform code, the first **4 represents a parameter to change (the first two are numerical one hundred, the first three on behalf of ten, on behalf of the first four bits)            Each one digital tube right lower leg with red highlights, representing the current position is selected, you can increase and decrease s to change it. Increase key: When using the Select to select a good to change the content, use this key parameter changes. Decrease key: When using the Select to select a good to change the content, use this key parameter changes. Enter key: When the parameter change is completed, this will confirm to confirm changes to the parameters and generate the corresponding waveform. Key combinations: Press the Select key, and then press the Enter key, release the Enter key, release the Select key, then select a key combination represents, press the Enter key will display different content. Instructions say to use the various waveforms, respectively, the method of operation:     A normal ECG waveform: ★ heart rate setting range :*****0bpm; (initial value: *0 bpm) ★ signal amplitude fixed.     2, positive and negative triangular waveforms: ★ Frequency range :*****0bpm; (initial value: *5 bpm) ★ amplitude range :0.**4Mv (*0:0.1 mV, **0:4 mV); ★ 2 modes, Mode 1: positive waveform Mode 2: Negative waveform; through a combination of keys.     8, the signal amplitude settings: ★ amplitude range: 0.1mV*4mV (*0:0.1 mV, **0:4 mV); (initial value: **0) ★ Please note that this amplitude settings will affect all waveforms. ★ Please note that the signal amplitude settings can affect the ECG waveform amplitude.

Pays: China
N ° de modèle: SKX-2000C
Prix FOB: 88 / Unit Obtenir le dernier prix
Localité: Xuzhou, Jiangsu, China
Prix de commande minimale: 88 per Unit
Commande minimale: 1 Unit
Packaging Detail: Bubble wrap drop resistance
Heure de livraison: 1-2 days can be shipped
Capacité de Fournir: 987 Unit per Week
Payment Type: Western Union
Groupe de produits : ECG monitoring equipment category

Send a direct inquiry to this supplier

To:

Ms. zhouxuemei < xuzhou mingsheng >

Je veux savoir: