Central air-conditioning system BUSCH cold water heater chiller By Busch (Shanghai) Machinery Technology Co,
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs. Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Central air-conditioning system BUSCH cold water heater chiller
Next

Central air-conditioning system BUSCH cold water heater chiller

38500 ~ 40000 USD / Set ( Negotiable )

|

1 Set Minimum Order

Pays:

China

N ° de modèle:

BBS-290S

Prix FOB:

38500 ~ 40000 USD / Set ( Negotiable ) Obtenir le dernier prix

Localité:

-

Prix de commande minimale:

38500 per Set

Commande minimale:

1 Set

Packaging Detail:

Plywood

Heure de livraison:

18 days after order

Capacité de Fournir:

10000 Set per Month

Payment Type:

T/T, L/C, Western Union

Contacter maintenant
Membre gratuit

Personne à contacter Maggie

Shanghai, Shanghai

Contacter maintenant

Spécification du produit

  • Cooling capacity:290 kW / 82.5 RT
  • Cooling power input:51.5 kW
  • Cooling current power:89.1A
  • Chilled water flow:50.0 m3/h
  • Well water flow:26.0 m3/h
  • Heating capacity:320 kW / 91.0 RT

La description

HS Code:*********0
Central air-conditioning system BUSCH cold water heater chiller
Model:BBS***0S
Cooling capacity:**0 kW / *2.5 RT
Cooling power :*1.5 kW
Cooling current power:*9.1A
Chilled water flow:*0.0 m3/h
Well water flow:*6.0 m3/h
Heating capacity:**0 kW / *1.0 RT
Heating power :*1.2 kW
Heating current power:**3.2 A
Heating water flow:*5.1 m3/h
Well water flow:*3.5 m3/h
Evaporator tube diameter:DN **0
Condenser tube diameter:DN **0
Size:***0mm***0mm****0mm
Weight:***0 kg
Power standard:**0V/**5V/**0V/*3P**0Hz/*0Hz
Refrigerant:R*2/R**7C/R**4a
Non-standard product and design:Acceptable

BBS water source heat pump chiller 
Water source heat pump chiller product`s technics

1.Water source heat pump central air-conditioning system operating principle
Geothermal water source heat pump air conditioning system uses the lake, the water, groundwater and geothermal water resources. With the help of compressing system, low-grade thermal energy of the water can be "taken out" and be transported into interior room by consuming small amount of energy in winter; in summer, indoor heat can be "released " into the water as cooling purposes .

2.Wider environment utilization 
Compared with air-cooled heat pump chiller , water source heat pump chiller is less influenced by environmental temperature. When heating in winter with no frost and defrosting interference , heating water temperature is more stable for cooling and heating in harsh environments without decay .

3.Running more stably
When water source heat pump chiller operates , the water temperature is quite stable. This makes the chiller runs more stable and reliable in cooling and heating work.

4.Recyclable cold water chiller system
Due to the increasingly energy shortage, waste heat recycling will have a long-term economic value. Basing on this fact, our enterprise developed a heat recycling chiller system, which can fully recycle the condensing waste heat originally released into the environment, which can be used in hotels , dormitories , toiletries and other occasions; If heat recycling technical parameters are needed, please contact our technical department to obtain.

5.Small vortex chiller 
The vortex chiller adopts import efficient and flexible scroll compressor. With the independent modular design, it brings various number of capacity combinations, easy accessibility and high reliability .

6.Balanced running performance and extended service life
Many of the chiller with compression, microcomputer automatic memory will be per compressor operation time, start the next time it will be activated running less time compressor. Similar in the discharge of the need, but also will be preferential the operation longer time to uninstall chiller, in order to achieve the balance of each compressor operation, extend the service life of the machine.

7.More energy efficiency
Water source heat pump chiller has high energy efficiency. Compared with general central air conditioning chillers, water source heat pump units can save over than *0% of energy, and it is one of the most energy-efficient central air conditioning chiller and in line with the national energy saving policy for customers to save considerable operating costs .
Compared with the central air-conditioning system applied water-cooled chillers,  the one with water source heat pump piping system is relatively more simple, and the systems does not need cooling tower for cooling and does not need boiler room for heating. This will bring more pollution reduction and less urban noise pollution. conversion of cooling and heating can be simply achieved by switching the water pipeline valve.

8.Environmental Friendly
In order to better protect the atmosphere, it can produce green environmental protection cooling medium refrigeration and air conditioning equipment not only in adopts HFC**7C and HFC**4a,but also in HCFC*2.

9.Y-Star triangle depressurization start mode
Half screw condensing water chillers use Y-Star triangle depressurization start mode. The starting electric current is only about 1.5 to 2 times as run-time current which greatly reducing the impact to the grid 

*0.Automatic capacity adjustment 
According to the air conditioning' demand, screw air-cooled chiller can automatically adjust load capacity. The standard chiller capacity adjustment is implemented by segmented or non-polar uninstalling method. One single machine can realize four different compressor capacity level, which are **0%, *5%, *0% and *5%. *5% level is used to start compressors. The induction capacity control can be achieved in the range of *5 to **0%. According to customer needs, the chiller capacity can be customized in a range from *5% to **0% smoothly.

*1.Energy conservation
The waste heat, which is generated from the pump cooling system, can be used to produce domestic hot water without additional consumption of electricity and fuel; almost zero cost ; no pollution ; no need to add other devices. The only thing is to directly connect water pipeline to access hot water.

*2.Remote control 
Each chiller is occupied with remote control function. The computer controller is equipped with RS**5 standard communication interfaces, open communication protocol. This will allow all kinds of building monitoring system connected and remote monitoring.

*3.Large screw condensing chiller 
Twin-screw compressor applies the world's most advanced 4th generation asymmetric patent tooth rotor machining by the British HOLROYD rotor and then grinding precision by the German KLINGELNBERG precision rotor grinding machine. This greatly reduces leakage and cooling loss. The usage of advanced three-stage oil network makes the oil filter ratio up to *9.7%, which greatly ensure machine oil return to the compressor , the wide range of built-in protection can ensure the compressor safe operation including 

*4.small vibration , low noise and high efficiency.
Except compressor refrigeration, other major components are imported quality products, such as the expansion valve , solenoid valve , filter drier , etc, which are all European and American quality products , have reliable performance and precise control .

*5.Touch screen computer interface 
The chiller is controlled by micro-computerized controller, and all are equipped with Germany Siemens PLC imported controller. The accuracy and intelligentize truly achieve perfect control of whole machine in order to ensure safe operation of the unit and the purpose of effective energy conservation. The machine is equipped with touch-screen interface,which is simple and customer-friendly.

*6.Test center 
The enterprise has a well-operated testing center , each air-conditioning unit have been injected refrigerant and refrigerant oil before leaving factory. After undergoing a rigorous simulation of the standard conditions and maximum operating mode detection, expansion valve can be adjusted to the best condition.




Notes: (screw and scroll stand-alone machine at room temperature ) , the default conditions:
1. Nominal cooling conditions : chilled water inlet / outlet water temperature *2 ℃/ 7 ℃; underground water out of the water temperature is *8 ℃ / *9 ℃
 The nominal thermal conditions : hot water inlet / outlet water temperature *0 ℃/ *5 ℃; underground water out of the water temperature *6℃/ 7 ℃
2. Refrigeration conditions requiring underground water temperature : *5 ℃ ~ *3 ℃ ;
Conditions of the heating requirements of the underground water temperature : *0 ℃ ~ *2 ℃
3. The evaporator and condenser water side design pressure is 1.0Mpa
4. Nominal conditions evaporation device water side of the dirt coefficient is 0.**8 m ? ° C / kW
5. Power standard **0V - *0HZ - 3 , the refrigerant is R*2 , the company can provide non-standard products according to customer requirements

Pays: China
N ° de modèle: BBS-290S
Prix FOB: 38500 ~ 40000 / Set ( Negotiable ) Obtenir le dernier prix
Localité: -
Prix de commande minimale: 38500 per Set
Commande minimale: 1 Set
Packaging Detail: Plywood
Heure de livraison: 18 days after order
Capacité de Fournir: 10000 Set per Month
Payment Type: T/T, L/C, Western Union
Groupe de produits : BBS water source heat pump chiller

Mots-clés correspondants Busch (Shanghai) Machinery Technology Co

Send a direct inquiry to this supplier

To:

Maggie < Busch (Shanghai) Machinery Technology Co >

Je veux savoir: