Prix FOB
Obtenir le dernier prix38500 ~ 40000 USD / Set ( Negotiable )
|1 Set Minimum Order
Pays:
China
N ° de modèle:
BBS-290S
Prix FOB:
38500 ~ 40000 USD / Set ( Negotiable )Obtenir le dernier prix
Localité:
-
Prix de commande minimale:
38500 per Set
Commande minimale:
1 Set
Packaging Detail:
Plywood
Heure de livraison:
18 days after order
Capacité de Fournir:
10000 Set per Month
Payment Type:
T/T, L/C, Western Union
Groupe de produits :
Personne àcontacter Maggie
Shanghai, Shanghai
HS Code:*********0
Central air-conditioning system BUSCH cold water heater chiller
Model:BBS***0S
Cooling capacity:**0 kW / *2.5 RT
Cooling power :*1.5 kW
Cooling current power:*9.1A
Chilled water flow:*0.0 m3/h
Well water flow:*6.0 m3/h
Heating capacity:**0 kW / *1.0 RT
Heating power :*1.2 kW
Heating current power:**3.2 A
Heating water flow:*5.1 m3/h
Well water flow:*3.5 m3/h
Evaporator tube diameter:DN **0
Condenser tube diameter:DN **0
Size:***0mm***0mm****0mm
Weight:***0 kg
Power standard:**0V/**5V/**0V/*3P**0Hz/*0Hz
Refrigerant:R*2/R**7C/R**4a
Non-standard product and design:Acceptable
BBS water source heat pump chillerÂ
Water source heat pump chiller product`s technics
1.Water source heat pump central air-conditioning system operating
principle
Geothermal water source heat pump air conditioning system uses the
lake, the water, groundwater and geothermal water resources. With
the help of compressing system, low-grade thermal energy of the
water can be "taken out" and be transported into interior room by
consuming small amount of energy in winter; in summer, indoor heat
can be "released " into the water as cooling purposes .
2.Wider environment utilizationÂ
Compared with air-cooled heat pump chiller , water source heat pump
chiller is less influenced by environmental temperature. When
heating in winter with no frost and defrosting interference ,
heating water temperature is more stable for cooling and heating in
harsh environments without decay .
3.Running more stably
When water source heat pump chiller operates , the water
temperature is quite stable. This makes the chiller runs more
stable and reliable in cooling and heating work.
4.Recyclable cold water chiller system
Due to the increasingly energy shortage, waste heat recycling will
have a long-term economic value. Basing on this fact, our
enterprise developed a heat recycling chiller system, which can
fully recycle the condensing waste heat originally released into
the environment, which can be used in hotels , dormitories ,
toiletries and other occasions; If heat recycling technical
parameters are needed, please contact our technical department to
obtain.
5.Small vortex chillerÂ
The vortex chiller adopts import efficient and flexible scroll
compressor. With the independent modular design, it brings various
number of capacity combinations, easy accessibility and high
reliability .
6.Balanced running performance and extended service life
Many of the chiller with compression, microcomputer automatic
memory will be per compressor operation time, start the next time
it will be activated running less time compressor. Similar in the
discharge of the need, but also will be preferential the operation
longer time to uninstall chiller, in order to achieve the balance
of each compressor operation, extend the service life of the
machine.
7.More energy efficiency
Water source heat pump chiller has high energy efficiency. Compared
with general central air conditioning chillers, water source heat
pump units can save over than *0% of energy, and it is one of the
most energy-efficient central air conditioning chiller and in line
with the national energy saving policy for customers to save
considerable operating costs .
Compared with the central air-conditioning system applied
water-cooled chillers, Â the one with water source heat pump
piping system is relatively more simple, and the systems does not
need cooling tower for cooling and does not need boiler room for
heating. This will bring more pollution reduction and less urban
noise pollution. conversion of cooling and heating can be simply
achieved by switching the water pipeline valve.
8.Environmental Friendly
In order to better protect the atmosphere, it can produce green
environmental protection cooling medium refrigeration and air
conditioning equipment not only in adopts HFC**7C and HFC**4a,but
also in HCFC*2.
9.Y-Star triangle depressurization start mode
Half screw condensing water chillers use Y-Star triangle
depressurization start mode. The starting electric current is only
about 1.5 to 2 times as run-time current which greatly reducing the
impact to the gridÂ
*0.Automatic capacity adjustmentÂ
According to the air conditioning' demand, screw air-cooled chiller
can automatically adjust load capacity. The standard chiller
capacity adjustment is implemented by segmented or non-polar
uninstalling method. One single machine can realize four different
compressor capacity level, which are **0%, *5%, *0% and *5%. *5%
level is used to start compressors. The induction capacity control
can be achieved in the range of *5 to **0%. According to customer
needs, the chiller capacity can be customized in a range from *5%
to **0% smoothly.
*1.Energy conservation
The waste heat, which is generated from the pump cooling system,
can be used to produce domestic hot water without additional
consumption of electricity and fuel; almost zero cost ; no
pollution ; no need to add other devices. The only thing is to
directly connect water pipeline to access hot water.
*2.Remote controlÂ
Each chiller is occupied with remote control function. The computer
controller is equipped with RS**5 standard communication
interfaces, open communication protocol. This will allow all kinds
of building monitoring system connected and remote monitoring.
*3.Large screw condensing chillerÂ
Twin-screw compressor applies the world's most advanced 4th
generation asymmetric patent tooth rotor machining by the British
HOLROYD rotor and then grinding precision by the German
KLINGELNBERG precision rotor grinding machine. This greatly reduces
leakage and cooling loss. The usage of advanced three-stage oil
network makes the oil filter ratio up to *9.7%, which greatly
ensure machine oil return to the compressor , the wide range of
built-in protection can ensure the compressor safe operation
includingÂ
*4.small vibration , low noise and high efficiency.
Except compressor refrigeration, other major components are
imported quality products, such as the expansion valve , solenoid
valve , filter drier , etc, which are all European and American
quality products , have reliable performance and precise control
.
*5.Touch screen computer interfaceÂ
The chiller is controlled by micro-computerized controller, and all
are equipped with Germany Siemens PLC imported controller. The
accuracy and intelligentize truly achieve perfect control of whole
machine in order to ensure safe operation of the unit and the
purpose of effective energy conservation. The machine is equipped
with touch-screen interface,which is simple and
customer-friendly.
*6.Test centerÂ
The enterprise has a well-operated testing center , each
air-conditioning unit have been injected refrigerant and
refrigerant oil before leaving factory. After undergoing a rigorous
simulation of the standard conditions and maximum operating mode
detection, expansion valve can be adjusted to the best
condition.
Notes: (screw and scroll stand-alone machine at room temperature )
, the default conditions:
1. Nominal cooling conditions : chilled water inlet / outlet water
temperature *2 ℃/ 7 ℃; underground water out of the water
temperature is *8 ℃ / *9 ℃
 The nominal thermal conditions : hot water inlet / outlet
water temperature *0 ℃/ *5 ℃; underground water out of the
water temperature *6℃/ 7 ℃
2. Refrigeration conditions requiring underground water temperature
: *5 ℃ ~ *3 ℃ ;
Conditions of the heating requirements of the underground water
temperature : *0 ℃ ~ *2 ℃
3. The evaporator and condenser water side design pressure is
1.0Mpa
4. Nominal conditions evaporation device water side of the dirt
coefficient is 0.**8 m ? ° C / kW
5. Power standard **0V - *0HZ - 3 , the refrigerant is R*2 , the
company can provide non-standard products according to customer
requirements
Pays: | China |
N ° de modèle: | BBS-290S |
Prix FOB: | 38500 ~ 40000 / Set ( Negotiable ) Obtenir le dernier prix |
Localité: | - |
Prix de commande minimale: | 38500 per Set |
Commande minimale: | 1 Set |
Packaging Detail: | Plywood |
Heure de livraison: | 18 days after order |
Capacité de Fournir: | 10000 Set per Month |
Payment Type: | T/T, L/C, Western Union |
Groupe de produits : | BBS water source heat pump chiller |