Printing and cooling water system with precise temperature control BUSCH water system By Busch (Shanghai) Machinery Technology Co,
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs. Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Printing and cooling water system with precise temperature control BUSCH water system
Next

Printing and cooling water system with precise temperature control BUSCH water system

39920 ~ 40860 / Set ( Negotiable )

|

1 Set Minimum Order

Pays:

China

N ° de modèle:

BBA-200SH

Prix FOB:

39920 ~ 40860 / Set ( Negotiable ) Obtenir le dernier prix

Localité:

-

Prix de commande minimale:

39920 per Set

Commande minimale:

1 Set

Packaging Detail:

Plywood

Heure de livraison:

18 days after order

Capacité de Fournir:

10000 Set per Month

Payment Type:

Western Union, L/C, T/T

Groupe de produits :

Contacter maintenant
Membre gratuit

Personne à contacter Maggie

Shanghai, Shanghai

Contacter maintenant

Spécification du produit

  • Heating capacity:225 kW / 64.0 RT
  • Whole unit power input:62.6 kW
  • Whole unit current power:109.6A
  • Start-up:Y-Star delta starting
  • Energy regulation:0-25%-50%-75%-100% or Stepless regulation
  • Evaporator water flow:34.4m3/h

La description

HS Code:*********0

Printing and cooling water system with precise temperature control BUSCH water system

Model:BBA***0SH

Cooling capacity:**0 kW / *6.9 RT

Heating capacity:**5 kW / *4.0 RT

Whole unit power :*2.6 kW

Whole unit current power:**9.6A

Compressor type:**6 asymmetric semi enclosed twin screw compressor

Start-up:Y-Star delta starting

Energy regulation:***5%**0%**5%***0% or Stepless regulation

Evaporator water flow:*4.4m3/h

Evaporator tube diameter:DN *0

Fan quantity:8 sets

Single fan power:0.*5 kW

Condenser air volume:****0 m3/h

Refrigerant charge:*1.0 kg

Size:***0mm****0mm****0mm

Weight:***0 kg

Power standard:**0V/**5V/**0V/*3P**0Hz/*0Hz

Refrigerant:R*2/R**7C/R**4a

Non-standard product and design:Acceptable



Screw air-cooled chiller(or heat pump)

Screw air-cooled chiller(heater) is the unit of which applicable cooling(heating) medium is air or water in summer(winter), and its secondary refrigerant is water. When connected with fan coil units, air conditioning box, air processor together, it can be used as half of concentration and centralized the central air conditioning system; Single cold- screw air-cooled chillers are widely used in various fields of refrigeration industry.



1.Comparing with water chiller

Compared with water chiller, Screw air-cooled chiller can get rid of huge cooling water system and a special air conditioning room. It also can be set up on the roof and outside. Installation and maintenance are very simple and convenient.



2.Precise stable water temperature 

As used for industrial cooling, Low temperature water that produced by air-cooled chiller could send directly to the equipment and containers, which need to keep freezing. In order to control precise stable water temperature, the water comes out of the chiller send to the Buffer pool firstly,then entrance the equipment or containers which need cooling.



3.Achieve annual refrigerate operation 

In the industrial cooling use aspect, screw air-cooled chiller can be used in above temperature **0°C and achieve annual refrigerate operation in order to meet the needs of cooling industrial in the winter refrigeration, and this can be used in different kinds of low temperature cooling. After adding appropriate antifreeze in the frozen water side, it can achieve the range of 0~**5°C in order to adapt to the different industrial cooling requirements. Usually we use Ethylene glycol ,calcium chloride, and sodium chloride as antifreeze solvent. In the application, customers are suggested set different antifreeze solution`s concentrations according to the water temperature.



4.Y-Star triangle depressurization start mode

Screw air-ccoled(or heat pump)chillers use Y-Star triangle depressurization start mode. The starting electric current is only about 1.5 to 2 times as run-time current which greatly reducing the impact to the grid 



5.External air cooled oil cooling device 

Screw air-cooled chiller(or heat) Cited the high exhaust gas temperature rise caused by lubricating oil overheating both in refrigeration environmental temperature is too high, heating environment temperature too low or Low-temperature industrial cooling water temperature is too low. In order to ensure good lubricating oil lubrication, we use External air cooled oil cooling device to cool down the temperature, Reduce the consumption of cooling capacity and Stable refrigeration system. 



6.Perfect protection function 

Screw water-cooled chiller have perfect protection function, such as power wrong phase lack protection , system high-voltage protection, system low voltage protection, double antifreeze protection, compressor overload protection, insufficient frozen water cooling protection, prevent frequent start protection, compressor built-in exhaust temperature coil overheat temperature protection and etc. These protection reduces many losses caused by all kinds of accidents .



7.Well separated frozen oil and refrigerants 

In order to more fully separate the frozen oil and refrigerants, external centrifugal efficient oil separator of low temperature cold water chiller can greatly reduce stranded frozen oil in the evaporator due to the low temperature. This ensure the compressor lubrication system security and also improve the heat transfer effectiveness of the evaporator.



8.External liquid spray technology 

To further ensure compressor motor will not be overheated. Screw air-cooled(or heatpump)chiller apply external liquid spray technology. With low temperature cooling media directly on the motor, it ensures the long-term and stable operation of the compressors.



9.Automatic capacity adjustment 

According to the air conditioning' demand, screw air-cooled chiller can automatically adjust load capacity. The standard chiller capacity adjustment is implemented by segmented or non-polar uninstalling method. One single machine can realize four different compressor capacity level, which are **0%, *5%, *0% and *5%. *5% level is used to start compressors. 



*0.Environmental Friendly

In order to better protect the atmosphere, it can produce green environmental protection cooling medium refrigeration and air conditioning equipment not only in adopts HFC**7C and HFC**4a,but also in HCFC*2.



*1.Balanced running performance

Many of the chiller with compression, microcomputer automatic memory will be per compressor operation time, start the next time it will be activated running less time compressor. Similar in the discharge of the need, but also will be preferential the operation longer time to uninstall chiller, in order to achieve the balance of each compressor operation, extend the service life of the machine.



*2.Remote control 

Each chiller is occupied with remote control function. The computer controller is equipped with RS**5 standard communication interfaces, open communication protocol. This will allow all kinds of building monitoring system connected and remote monitoring. The system supports building automation BACne agreement, TPC/IP, convenient connection with the system; The remote control unit can be directly connected through RS**2 and RS**5, RS**2 universal serial interface and through the BACnet converter pulled into a BMS intelligent building control system. 



*3.Defrost 

Accurate design aluminum pieces from the maximum is to reduce frosting probability. Analysis and judgment can be achieved by fully combining of time, temperature and pressure for the comprehensive. This achieves the on-demand defrosting, reach perfect level of defrosting, and extend the defrosting interval.



*4.Waste heat & secondary condensation

Without additional consumption of electricity and fuel , the waste heat generated from the chillers can produce domestic hot water. These results can be achieved in almost zero cost, zero pollution, no more other additional devices. The only thing to do is just to directly access water pipeline to access hot water

Due to the secondary condensing progress, it can appreciably reduce condensate temperature and pressure, and it can also raise the efficiency of refrigeration to some extent.  



*5.Heat recovery type chiller

Due to the increasingly energy shortage, waste heat recycling will have a long-term economic value. Basing on this fact, our enterprise developed a heat recycling chiller system, which can fully recycle the condensing waste heat originally released into the environment, which can be used in hotels , dormitories , toiletries and other occasions; If heat recycling technical parameters are needed, please contact our technical department to obtain.



*6.Compressor & other major refrigeration components

Twin-screw compressor applies the world's most advanced 4th generation asymmetric patent tooth rotor machining by the British HOLROYD rotor and then grinding precision by the German KLINGELNBERG precision rotor grinding machine. This greatly reduces leakage and cooling loss. The usage of advanced three-stage oil network makes the oil filter ratio up to *9.7%, which greatly ensure machine oil return to the compressor , the wide range of built-in protection can ensure the compressor safe operation including small vibration , low noise and high efficiency.

Except compressor refrigeration, other major components are imported quality products, such as the expansion valve , solenoid valve , filter drier , etc, which are all European and American quality products , have reliable performance and precise control .



*7.Touch screen computer interface 

The chiller is controlled by micro-computerized controller, and all are equipped with Germany Siemens PLC imported controller. The accuracy and intelligentize truly achieve perfect control of whole machine in order to ensure safe operation of the unit and the purpose of effective energy conservation. The machine is equipped with touch-screen interface,which is simple and customer-friendly.



*8.Test center 

The enterprise has a well-operated testing center , each air-conditioning unit have been injected refrigerant and refrigerant oil before leaving factory. After undergoing a rigorous simulation of the standard conditions and maximum operating mode detection, expansion valve can be adjusted to the best condition.







Notes: (Normal temperature) default conditions 

1.Parameter of the refrigeration nominal conditions : chilled water inlet / outlet water temperature is *2℃/ 7 ℃; Ambient temperature is *5℃ . The nominal operating conditions of the heating parameters : hot water inlet temperature is *0℃, water  temperature outlet is *5 ℃ , environmental dry bulb temperature is 7℃, wet bulb temperature is 6℃;

2. Temperature conditions: cooling water temperature range is 5 ℃ ~ *5 ℃, water heating temperature range is *5 ℃ ~ *0 ℃, the environment temperature range is:**0 ℃ ~ *3 ℃ 

3. The water side of the evaporator pressure is 1.0Mpa, the test pressure is 1.6 Mpa

4. Nominal conditions evaporation device water side of the dirt coefficient is 0.**8 m ? ° C / kW

5. In addition to the above specifications and requirements , the company can provide non-standard products according to customer requirements

Pays: China
N ° de modèle: BBA-200SH
Prix FOB: 39920 ~ 40860 / Set ( Negotiable ) Obtenir le dernier prix
Localité: -
Prix de commande minimale: 39920 per Set
Commande minimale: 1 Set
Packaging Detail: Plywood
Heure de livraison: 18 days after order
Capacité de Fournir: 10000 Set per Month
Payment Type: Western Union, L/C, T/T
Groupe de produits : BBA air cooled screw chiller

Mots-clés correspondants Busch (Shanghai) Machinery Technology Co

Send a direct inquiry to this supplier

To:

Maggie < Busch (Shanghai) Machinery Technology Co >

Je veux savoir: