Sell DEMISTER Features (Mesh Pad type) By NINGBO TIANDA CHEMICAL (T.C.I) CO., LTD., China
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs. Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell DEMISTER Features (Mesh Pad type)

Sell DEMISTER Features (Mesh Pad type)

10 / Piece

|

Minimum Order

Localit:

china

Prix de commande minimale:

Commande minimale:

10 Piece

Packaging Detail:

-

Delivery Time:

10

Supplying Ability:

10000000 Piece per Week

Payment Type:

Western Union

Contacter maintenant
Membre gratuit

Personne à contacter Mr. Tony

No.181,HuiZhan Road ,Ningbo city, China 315000, Ningbo, Other

Contacter maintenant

Description


DEMISTER Features (Mesh Pad type)

Specification
TCI  mesh mist eliminators are manufactured in a wide variety of metals and
synthetics of which the following are supplied as standard:-
Stainless steels (types **4, **4L, **6, **6L, **1, **0)
Monel
Nickel & nickel alloys
Copper & copper alloys
Glass wool or fibre
Polypropylene
Halar / PTFE
The wire mesh may be knitted and formed to provide a wide range of specific
properties to suit various applications. The following is a list of standard mesh styles
that we supply:-
STYLE APPLICATIONS
HE High efficiency removal of fine mists
GP General purpose (maximum efficiency with low pressure loss)
DS Dirty service where fouling is an issue
Mist Eliminator Design
Mesh pads should be sized so that the face area provides a vapour rate of
approximately *0% of the maximum allowable re-entrainment velocity. For
estimation purposes, suitable design velocities occur at a K-factor of 0.*1 m/s for
vertical flow, or 0.*5 for horizontal gas flow (due to better drainage) where:-
vs = K . {( L - V )/ V} 0.5
where vs = Actual vapour velocity (m/s)
V
= Vapour density (kg/m3)
L
= Liquid density (kg/m3)
Operating pressure loss across the pad within the above design range is normally
less than 0.5 kPa depending upon mesh density, pad thickness, liquid loading and
vapour rate. An approximate pressure drop can be estimated from the formula:
Wet P (kPa) = C . (L – V) . K2 . t
Where C = 0.*0 for a typical ‘GP’ style mesh demister, and t is the pad thickness in
metres. Note that the dry pressure drop is about half of the wet figure.