Specific Surface Area and micropore Distribution AnalyzerJW-004A

Specific Surface Area and micropore Distribution AnalyzerJW-004A

( Negotiable )

|

Minimum Order

Localité:

Beijng, China

Prix de commande minimale:

-

Commande minimale:

1 Set

Packaging Detail:

-

Delivery Time:

30 days

Supplying Ability:

1000 Set per Year

Payment Type:

T/T, L/C, D/P, PayPal, Other

Contacter maintenant
Membre gratuit

Personne à contacter Ms. Wendy

A Block,No.23,South Binhe Road, Beijing, Beijing

Contacter maintenant

Description

Test principle: the static volumetric method, gas adsorption;
Analysis Models: BET, Langmuir, BJH, t-plot, DR, ?s-plot, MP, HK, SF, and NLDFT;
Measuring range: surface area ? 0.**5M2/g, no upper limit; mesoporous and macroporous 2 _ **0nm; micropore size 0.*5nm _ 2nm; pore volume 0.***1 cm3/g, no upper limit.
Sorption gas:N2 (high purity); Ar, Kr, CO2, CH4, etc. available
Analysis Stations: 2 ports. One analysis station can test the micropore and the other can test the mesorpore.
Sample Type: powders, granules, fibers, flakes and other materials
Pressure Sensor: ***0torr (**3kpa), *0torr (1.*3kpa); 1torr (0.**3kpa) or 0.1torr (0.***3kpa); accuracy? 0.*5%?P.S?
P0 tube: there is a separate P0 tube in every analysis port, two in all, controlled by a separate pressure sensor, completely separates from the analysis port, real-time detecting the nitrogen saturation vapor pressure, and participating in the theoretical calculation; also the atmospheric input method to determinate the P0 accurately;
Cold trap tube: sample degassing system has a special cold trap device that can effectively remove the water, hazardous substances and other impurities, degassed from the special sample, and it can avoid the contamination of the vacuum system;
Degassing system: Parity, ectopic vacuum degassing pretreatment systems are controlled by separate pressure sensors. Two samples can be analyzed simultaneously, also two samples can be degassed in degassing ports; two independent sample degassing stations are separate from the sample analysis ports. The degassing system has two independent heating packages, two independent temperature control systems, which can be programmed by temperature control; you can choose another four external vacuum degassing pretreatment system;
Degassing temperature: room temperature ***0?, accuracy 1?;
Test Efficiency: multi-point BET surface area _*5 minutes per sample; Determination micro pore size distribution from adsorption and desorptionisotherms_**8h persample.
Nitrogen Partial Pressure: P/Po **0*8 _ 0.**8, the minimum resolvablerelative pressure 5 ***7
Ultimate vacuum:? *0P*6 Pa?7.**0*9torr?, mechanical pump and turbo molecular pump.
PressureAccuracy: ? 0.*5% (P.S)
Measurement Accuracy: ?1.0%?surface area?; ?0.*1nm?the most frequency micro pore? ?0.*4% (True density)??1.5% (STSA)
Operation Mode: Automatic