The detectors are photo-electronic detector uses a state
of-the-art
optical sensing chamber. This detector is designed to provide
open
area protection and to be used with most security alarm control
panel.
Two LEDs on each detector provide local **0° visible alarm
indication. They flash every six seconds indicating that power
is
applied and the detector is working properly. The LEDs latch on
in
alarm. LEDs will be off when a trouble condition exists
indicating
that the detector sensitivity is outside the listed limit. The
alarm can
be reset only by a momentary power interruption.
The detector that initiated the alarm condition will have its red
LED
and relays latched until reset by panel.
Heat detector and smoke & heat detector combine a photo
electronic sensing chamber and a temperature heat detector.
2. SPECIFICATIONS
Operating Voltage Range: 9 to *8 VDC Volts Non-polarized
Standby Current: ≤**0μA
Maximum Alarm Current (LED on): ≤*5mA
Alarm Relay Contact Ratings: *@********************g Humidity Range: ≤*5%RH(*0°C±2°C) Relative Humidity,
Non-condensing
Operating Temperature Range: **0°C to *0°C (*4°F to **2°F)
Smoke Alarm Sensitivity: 1.*6±.*6%FT
Temperature Alarm Sensitivity: *7°C (**5°F) A1R (only for with heat
sensor)
Height: *5 mm installed in Base
Diameter: **3 mm
3. INSTALLATION
NOTE: All wiring must conform to applicable local codes,
ordinances, and regulations.
INSTALL THE DETECTOR BASE
1. Open area smoke or heat detectors are intended for
mounting on a ceiling or a wall in accordance with the fire
standard in your country.
2. Attach mounting base to ceiling or wall. The base of
the detector can be mounted directly onto an electrical
junction box such as an octagonal (*5mm, *0mm or
**0mm), a round (*5mm), or a square (**0mm) box
without using any type of mechanical adapter.
3. Position all wires flat against terminals, and fasten the
wires on the terminals, See Figure 1.
4. Terminals function description:
Terminal 1: Relay Output -COM
Terminal 2: Relay Output – NO/NC (default NO)
Terminal 3: DC Power –
Terminal 4: DC Power +
Pays: | China |
N ° de modèle: | Smoke detector YT142 |
Prix FOB: | 8 ~ 10 / Piece Obtenir le dernier prix |
Localité: | China |
Prix de commande minimale: | 8 per Piece |
Commande minimale: | 1 Piece |
Packaging Detail: | 100pcs/set |
Heure de livraison: | 3-15 day |
Capacité de Fournir: | 10000 Piece per Month |
Payment Type: | T/T, Western Union, Other |
Groupe de produits : | 4-Wire Smoke Detector |