• Locate the first alarm in the immediate area of the bedrooms
but
not in the bedrooms. Try to protect the exit path as the
bedrooms
are usually farthest from the exit. If more than one sleeping
area
exists, locate additional alarms adjacent to each sleeping
area.
• Locate additional alarms in the bedrooms if required.
• Locate additional alarms to protect any stairway as stairways
act
like chimneys for smoke and heat.
• Locate at least one alarm on every floor level.
• Locate an alarm in every room where electrical appliances
are
operated (i.e. portable heaters or humidifiers).
• Locate an alarm in every room where someone sleeps with the
door closed. The closed door may prevent the alarm from waking
the sleeper.
• Smoke, heat, and combustion products rise to the ceiling
and
spread horizontally. Mounting the smoke alarm on the ceiling in
the
center of the room places it closest to all points in the room.
Ceiling
mounting is preferred in ordinary residential construction.
• When mounting an alarm on the ceiling, locate it at a minimum
of
4†(*0 cm) from the side wall (see Figure 1).
• When mounting the alarm on the wall, it is best to use an
inside
wall with the top edge of the alarm at a minimum of 4†(*0 cm)
and a
maximum of *2†(*0.5 cm) below the ceiling, (see Figure 1).
• Put smoke alarms at both ends of a bedroom hallway or large
room if the hallway or room is more than *0 feet (9.1 m) long.
• Install Smoke Alarms on sloped, peaked or cathedral ceilings at
or
within 3ft (0.9m) of the highest point (measured horizontally).
(see
Figure 2).
2. LOCATIONS TO AVOID FOR ALARMS
Alarms must not be located within 3 feet of the following:
• Supply and return registers used for forced air heating
and air conditioning.
• Ceiling fans and other high air flow areas.
• Bathrooms which contain a tub or shower.
In general, alarms should not be located:
• In the garage. Products of combustion are present
when you start your automobile.
• In an area where the temperature may fall below *0ºF
or rise above **0ºF.
• In dusty areas. Dust particles may cause nuisance
alarms or failure to alarm.
• In a kitchen or cooking area where steam and smoke
from burning food or toast can cause nuisance alarms.
• Near fluorescent lights. Electronic “noise†may cause
nuisance alarms.
Pays: | China |
N ° de modèle: | DG313 |
Prix FOB: | 6 ~ 8 / Piece Obtenir le dernier prix |
Localité: | China |
Prix de commande minimale: | 6 per Piece |
Commande minimale: | 1 Piece |
Packaging Detail: | 60pcs/set |
Heure de livraison: | 3-15 day |
Capacité de Fournir: | 10000 Piece per Month |
Payment Type: | T/T, Western Union, Other |
Groupe de produits : | battery smoke alarm |