Prix FOB
Obtenir le dernier prix0 ~ 50
|1 Set Minimum Order
Pays:
China
N ° de modèle:
VA-48
Prix FOB:
0 ~ 50 Obtenir le dernier prix
Localité:
-
Prix de commande minimale:
-
Commande minimale:
1 Set
Packaging Detail:
egg incuabtor : Carton with good Foam
Heure de livraison:
3 to 5 days after you confirmed your order
Capacité de Fournir:
1000 Set per Month
Payment Type:
Money Gram, Western Union, T/T
Groupe de produits :
-
Personne à contacter Belinda
nanchang, Jiangxi
***4 CE Marked Mini Egg Incubators VA**8
Â
   Model number  |
      VA**8         |
   Gross Weight  |
      7KG |
    Power  |
      *0W |
  Packaging Size  |
      *4**4**0CM |
   Voltage  |
      **0V/ **0V/ **0V&*2V |
   Capacity   |
         *8 chicken eggs        *4 duck/turkey eggs       *8 bird eggs      *4 goose eggs |
Â
Â
 Incubator Characteristic
It is suitable for the families and specialized households to incubate chickens, birds, ducks and geese, etc. This machine is produced under strict CE test and has good reputation from the peasants in the rural area ,especially in eastern European countries. The machine has the characteristics of strong practicality, Easy operation and long service life, etc.
Â
Â
Incubator Product Function
 1) Automatic egg turning
 2) High and low temperature alarm, high and low humidity alarm
 3) Recorded days of incubationÂ
 4) Add water outside with free water dropper
 5) Lower cover is transparent, very easy to observe
 6) Easy to operate. Automatic temperature control and automatic display for temperature&humidity
Â
1. Testing you unit for the first time:
1.1 Connect the egg turner plug to the control plug inside the egg compartment.
1.2 Connect the provided power supply to the back of the unit and your power source.
1.3 Switch on your power source.
1.4 Switch your unit on.
1.5 You will hear an alarm sounding due to low temperature/humidity.
1.6 Press any of the green s to cancel the alarm.
1.7 By opening the incubator and filling the water channels you will notice the humidity
     reading increase.
1.8 Let the unit run for 2 hours to note the egg turner turning.
Â
2. Setting the temperature
2.1 Push “SET†once.
2.2 Push “+†or “-“ to select the desired temperature.
2.3 Push “SET†once more to exit.
- These incubators are factory set at *8oC, I found the chicks hatch at day *9 toÂ
 *0 meaning the temperature being to high. Using the method as described
 above. I recommend you set the temperature at *7.6oC.
Â
3. Temperature alarm parameter settings (AL and AH)
The temperature alarm is factory set to sound at 1oC over or below the set temperature. This is sufficient and you do not need to make any changes to these settings.
3.1 Low temperature alarm parameter setting. (AL)
3.1.1 Press and hold “SETT†for 3 sec.
3.1.2 Push “+†or “-“ until code “AL†appears in the temperature screen.
3.1.3 Push “SETâ€
3.1.4 Push “+†or “-“ to adjust to your desired lower alarm setting.
Â
3.2 Higher temperature alarm parameter setting (AH)
3.2.1 Press and hold “SETT†for 3 sec.
3.2.2 Push “+†or “-“ until code “AH†appears in the temperature screen.
3.2.3 Push “SETâ€
3.2.4 Push “+†or “-“ to adjust to your desired higher alarm setting.
Â
4. Humidity alarm parameter settings (AS)
The humidity is factory set to sound at *0% .
(Note: it can be adjusted according to your incubating request.)
4.1 humidity parameter setting. (AS)
4.2 Press and hold “SET†for 3 sec.
4.3 Push “+†or “-“ until code “AS†appears in the temperature screen.
4.4 Push “SETâ€
4.5 Push “+†or “-“ to adjust to your desired humidity.
- By filling both water channels depend on the local humidity levels and the time of year, and how much water inside the incubator and humidity to determine whether it need to add water or not.
Â
5. Calibrating temperature sensor reading (CA)
The thermometer correct reading is set at 0oC. The reading given by the thermometer can be adjusted if you find that the temperature reading is incorrect using a calibrated thermometer.
5.1 Calibrating the temperature sensor measurement. (CA)
5.2 Press and hold “SETT†for 3 sec.
5.3 Push “+†or “-“ until code “CA†appears in the temperature screen.
5.4 Push “SETâ€
5.5 Push “+†or “-“ to adjust to the correct measurement.
- Note that the adjustment is the difference between the thermometer readings
 and should be adjusted with “- “ if the temperature reading of the incubator is to
 high and normal value (indicating + value) if the incubator reading is too low.
Â
Â
6. Temperature Upper and lower limit set (HS and LS)
HS - (High Set) and LS- (Low Set) set the limit of the setting range of the desired temperature setting (incubating temperature adjustment)
If HS is set as *8.2 and LS is set as *7.4, then the desire temperature (incubating temperature adjustment) can only be changed from *8.2 to *7.4, so the minimum temperature shall be limited to *7.2 even if the “-“ is kept on pressing. The same goes for the High Set Limit.
Â
- This is to prevent accidental out of range temperature setting.
Â
7. Heating Element (HU and HD)
Parameter HU and HD, set by factory and is not supposed to be modified by user.
HU -Default setting is *8 ( I believe it’s Heat Up power setting, controlling the start up power to the heater to bring it up to the desired temperature setting (incubating temperature adjustment). Setting Range 1~*0.
HD - Default setting is *1 ( I believe it’s Heat Down power setting, controlling the power to maintain the heater at the desired temperature setting (incubating temperature adjustment).
Setting Range 1~*0.
Â
Pays: | China |
N ° de modèle: | VA-48 |
Prix FOB: | 0 ~ 50 Obtenir le dernier prix |
Localité: | - |
Prix de commande minimale: | - |
Commande minimale: | 1 Set |
Packaging Detail: | egg incuabtor : Carton with good Foam |
Heure de livraison: | 3 to 5 days after you confirmed your order |
Capacité de Fournir: | 1000 Set per Month |
Payment Type: | Money Gram, Western Union, T/T |
Groupe de produits : | - |