Prix FOB
Obtenir le dernier prix|
- Minimum Order
Pays:
China
N ° de modèle:
B-2000
Prix FOB:
Localité:
-
Prix de commande minimale:
-
Commande minimale:
-
Packaging Detail:
-
Heure de livraison:
-
Capacité de Fournir:
-
Payment Type:
-
Groupe de produits :
Personne àcontacter Mr. Andrew
Rm. 1013, Luozi Pinge, Shiqi Street, Yinzhou District,Ningbo, Zhejiang 315153,China, Ningbo, Zhejiang
SPECIFICATIONS:
Model: B****0
POWER
Power Requirements: AC**0V *0%, *0Hz 2%
Power Input: ≤**0VA
Refer to IEC******1, this equipment belongs to Class I, Type B.
Its operation is Continuous.
ALARM
Power Alarm
Power Failure: Activates if primary power to the Incubator
Fails or the power wire is accidentally
Disconnected from the wall receptacle.
Fan Alarm
Fan Failure: Activates if Fan motor malfunctions. Sensor
Alarm
Air Sensor Failure: Air Sensor malfunction, refer unit to
service.
Sensor Out of Position: Activated when Sensor is not in correct
position To perform calibration or continue operation.
Skin Sensor Disconnected: Activated during Skin Control Mode when
Skin Sensor is disconnected from Temperature Controller. Skin
Sensor Failure: Activated when Skin Sensor malfunctions.
Deviation Alarm High Air Temperature: Activated if displayed Air
Temperature is 1.5 centigrade above set point
Low Air Temperature: Activated if displayed Air Temperature
2.5centigrade below set point
Skin Temperature: Activated if displayed Skin Temperature is 1.0
centigrade above set point
Low Skin Temperature: Activated if displayed Skin Temperature is
1.0Over Temperature Alarm
Over Air Temperature: Activated when displayed Air TemperatureWas
approach *8centigrade for set temperature ≤*7centigrade, Or
approach *0centigrade for set temperature >*7centigrade in Air
Mode.
Over Skin Temperature: Activated when displayed Skin Temperature
was approach *8centigrade for set temperature ≤*7centigrade, Or
approach *9centigrade for set temperature >*7centigrade in
Skin Mode. System Alarm
System Failure: Activated if Temperature Control System
malfunctions.
TEMPERATURE CONTROLRANGEAND CORRELATIVE SPECIFICATIONS
Air Temperature: *0centigrade ~*7centigrade, for set temperature
≤*7centigrade
*7centigrade ~*9centigrade, for set temperature
>*7centigrade
Skin Temperature: *0centigrade ~*7centigrade, for set temperature
≤*7centigrade
*7centigrade~*8centigrade, for set temperature
>*7centigrade
Temperature Rise Time: ≤*0min
Temperature Variability: 0.5centigrade
Temperature Uniformity: ≤ 1 centigrade
Skin Sensor Precision: ≤0.3centigrade
ENVIRONMENT REQUIREMENT
Environment Temperature
Operation Temperature Range**0centigrade ~**0centigrade
Store Temperature Range **0centigrade ~**0centigrade
Environment Humidity
Operation Humidity Range: *0%~*5%
Store Humidity Range: ≤*0%
Atmospheric Pressure Range: **0hPa~***0hPa
OTHER SPECIFICATION
Noise Level Within Hood Environment ≤*5dB(Environment noise below
*5dB Carbon Dioxide (CO2) Level within the Hood Less than 0.5%
when a mixture of CO2
In air is delivered at **0ml/min
At point *0cm above the center of the mattress.
Air Velocit y Over Mattress less than: 0.*5m/s
Infant Bed Max Load: *0kg
Transfusion Shelf Max Load: 2kg
Shelf Max Load:
Cabinet Max Load: 6kg
Pays: | China |
N ° de modèle: | B-2000 |
Prix FOB: | Obtenir le dernier prix |
Localité: | - |
Prix de commande minimale: | - |
Commande minimale: | - |
Packaging Detail: | - |
Heure de livraison: | - |
Capacité de Fournir: | - |
Payment Type: | - |
Groupe de produits : | medical equipment |