Infant Incubator (B-2000) By China Shikang Medical Equipment Group Limited,
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs. Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Infant Incubator (B-2000)
Next

Infant Incubator (B-2000)

|

- Minimum Order

Pays:

China

N ° de modèle:

B-2000

Prix FOB:

Localité:

-

Prix de commande minimale:

-

Commande minimale:

-

Packaging Detail:

-

Heure de livraison:

-

Capacité de Fournir:

-

Payment Type:

-

Groupe de produits :

Contacter maintenant

Personne à contacter Mr. Andrew

Rm. 1013, Luozi Pinge, Shiqi Street, Yinzhou District,Ningbo, Zhejiang 315153,China, Ningbo, Zhejiang

Contacter maintenant

Spécification du produit

La description


SPECIFICATIONS:
Model: B****0
POWER
Power Requirements: AC**0V *0%, *0Hz 2%
Power Input: ≤**0VA
Refer to IEC******1, this equipment belongs to Class I, Type B. Its operation is Continuous.
ALARM
Power Alarm
Power Failure: Activates if primary power to the Incubator
Fails or the power wire is accidentally
Disconnected from the wall receptacle.

Fan Alarm
Fan Failure: Activates if Fan motor malfunctions. Sensor Alarm
Air Sensor Failure: Air Sensor malfunction, refer unit to service.
Sensor Out of Position: Activated when Sensor is not in correct position To perform calibration or continue operation.
Skin Sensor Disconnected: Activated during Skin Control Mode when Skin Sensor is disconnected from Temperature Controller. Skin Sensor Failure: Activated when Skin Sensor malfunctions.
Deviation Alarm High Air Temperature: Activated if displayed Air Temperature is 1.5 centigrade above set point
Low Air Temperature: Activated if displayed Air Temperature 2.5centigrade below set point

Skin Temperature: Activated if displayed Skin Temperature is 1.0 centigrade above set point
Low Skin Temperature: Activated if displayed Skin Temperature is 1.0Over Temperature Alarm
Over Air Temperature: Activated when displayed Air TemperatureWas approach *8centigrade for set temperature ≤*7centigrade, Or approach *0centigrade for set temperature >*7centigrade in Air Mode.

Over Skin Temperature: Activated when displayed Skin Temperature was approach *8centigrade for set temperature ≤*7centigrade, Or approach *9centigrade for set temperature >*7centigrade in Skin Mode. System Alarm
System Failure: Activated if Temperature Control System malfunctions.

TEMPERATURE CONTROLRANGEAND CORRELATIVE SPECIFICATIONS
Air Temperature: *0centigrade ~*7centigrade, for set temperature ≤*7centigrade
*7centigrade ~*9centigrade, for set temperature >*7centigrade
Skin Temperature: *0centigrade ~*7centigrade, for set temperature ≤*7centigrade
*7centigrade~*8centigrade, for set temperature >*7centigrade
Temperature Rise Time: ≤*0min
Temperature Variability: 0.5centigrade
Temperature Uniformity: ≤ 1 centigrade
Skin Sensor Precision: ≤0.3centigrade
ENVIRONMENT REQUIREMENT

Environment Temperature
Operation Temperature Range**0centigrade ~**0centigrade
Store Temperature Range **0centigrade ~**0centigrade
Environment Humidity
Operation Humidity Range: *0%~*5%
Store Humidity Range: ≤*0%
Atmospheric Pressure Range: **0hPa~***0hPa
OTHER SPECIFICATION
Noise Level Within Hood Environment ≤*5dB(Environment noise below *5dB Carbon Dioxide (CO2) Level within the Hood Less than 0.5% when a mixture of CO2

In air is delivered at **0ml/min
At point *0cm above the center of the mattress.
Air Velocit y Over Mattress less than: 0.*5m/s
Infant Bed Max Load: *0kg
Transfusion Shelf Max Load: 2kg
Shelf Max Load:
Cabinet Max Load: 6kg

Pays: China
N ° de modèle: B-2000
Prix FOB: Obtenir le dernier prix
Localité: -
Prix de commande minimale: -
Commande minimale: -
Packaging Detail: -
Heure de livraison: -
Capacité de Fournir: -
Payment Type: -
Groupe de produits : medical equipment
Infant Incubator (B-2000)

Send a direct inquiry to this supplier

To:

Mr. Andrew < China Shikang Medical Equipment Group Limited >

Je veux savoir: