La description
Â
GCS AC low voltage withdrawable
switchgear
Iã€ï¿½General
l        GCS
is modularized, multi-functional low voltage distribution
switchgear, which is applicable to metallurgy, petroleum,
chemical industrial, industrial and mining enterprises and all
the situations high reliable low voltage system, distribution
system and motor control system are needed.
l        The
structure of the cabinet body of GCS has high flexibility
1.The elements of many types and
specifications can be installed in the cabinet according to your
requirements or different using situationsï¼›
2.The polytype feeder units can be
installed in the same list of the cabinet or in the same cabinet
according to different electricity equipments. E.g.: the feeding
loop and the motor control loop can be wired together.
l        GCS
series low voltage switchgear can meet your need completely. It
is applicable to all low voltage systems of ***0A or
below.
l        GCS
can supply you high level reliability and safety. Its humanized
design enhances the protection both for the human body and for
the equipments.
l        GCS
is full assembly structure, whose special cross-sectional
material and the connection mode as well as the compatibility
with the elements can meet the requirements from the working
period and the continuity of the power supply.
l        Execution
standard:IEC****9,GB***1.1
Â
Â
IIã€ï¿½Technical data
l        general
data
n        application
occasions: power distribution and motor control
n        Execution
standard:IEC****9, GB***1.1
n        environmental
temperature:*5℃ï½ï¿½**0℃
n        relative
humidity ≤*0% when the highest temperature is
+*0℃; A higher humidity is allowable if the temperature is
lower,
e.g.: *0% when *0%.
n        installation
site:indoor installation
n        height
above sea level:≤**0m
l        mechanized
data
n        Inlet
and outlet: cables/bus bar bridge
n        Cable
inlet and outlet: roof/bottom
n        Wiring
mode: front/back
n        protection
degree of the shell:IP*0, IP*0
n        Functional
unit isolating mode: completely or partly
l        dimensions
of the cabinet body
n        height:***0
n        width:**0,
**0, ***0(**0, **0 are for MCC back outlet mode)
n        depth:**0,
**0, ***0
n        the
surface: high voltage static epoxy powder spray ≥*0u
n        color:according
to the requirement from the user
l        electric
data
n        rated
insulating voltage:to AC***0V
n        rated
working voltage:to AC**0V
n        rated
frequency:*0/*0HZ
n        rated
impact tolerance voltage:8KV
n        voltage
of the auxiliary circuit:AC**0V, **0V/DC**0V
n        overvoltage
degree:Ⅲ
n        pollution
degree:3
n        rated
current:***0A
n        rated
current of the horizontal bus bar:***0A
n        rated
current of the vertical bus bar:***0A, ***0A
l        the
horizontal bus bar
n        rated
short time tolerance current:*0/*0KA
n        rated
peak tolerance current:**5/**6KA
l        the
vertical bus bar
n        rated
short time tolerance current:*0KA
n        rated
peak tolerance current:**5KA
l        grounding
system TT, IT, TN-S, TN-C-S
l        the
max inlet/outlet circuit breaker ***0A
Â
IIIã€ï¿½Structure and characteristics
The frame
l        The
frame of the cabinet selects tee bend connection of 8MF
cross-sectional material (modulus: E=*0mm), which is assembled
after fastened by locking screws and high strength screws. There
are many specifications and dimensions of the cross-sectional
materials. Different frame can be assembled according to
different cabinet type and the actual requirements
l        The
cabinet body is made of cold rolled steel and import A-zinc alloy
plates.
The shell
Many kinds of protection boards can be added to the frame
according to the cabinet structure and the actual requirements.
l        Cabinet
front
n        transparent
glass door
n        ordinary
door plate
n        withdrawable
pane
n        ventilation
door
l        Cabinet
back
n        back
open
n        sealing
board at the back of the cabinet installed by the wall, fixed by
the screws directly
l        Cabinet
side: the side board fixed by the screws
l        The
roof of the cabinet
n        Roof
cover (with ventilation holes, match respective bushing according
to the cable size when wiring).
l        The
bottom of the cabinet: bottom covers (match respective bushing
according to the cable size).
l        There
are integrated isolating boards among the cabinets.
Â
Assembly type of the
cabinets
                Â
Â
The drawer cabinet(MCC)
l        The
drawer cabinet is composed of the drawers, cabinet frame and the
relative components. All the elements are fixing installed in the
drawers. The module of the height of the drawer layer is **0mm.
there are five dimension-series: 1/2unit, 1unit, 1.5/2unit, the
second unit and the third unit. The rated current of the unit
loop is below **0A.
n        *1
one unit drawers or *2 1/2 unit drawers for the most can be
installed in each MCC.
n        It
is mainly used for motor control loop or power distribution.
l        The
fixed cabinet
      This kind of
cabinet is mainly used for the inlet cabinet, contact cabinet,
capacity compensator, frequency controller and soft starter.
l        The
mix cabinet
n        The
drawer unit and the fixed unit can be mixed assembled in one
cabinet. 8E is a unit according to the module.
n        It
is applicable to the situation that the distribution loop and the
motor control loop both exist.
l        The
fixed isolating cabinet
n        Each
loop unit are isolating with each other. Plug circuit breaker or
withdrawable circuit breaker is adopted for the convenient of the
maintenance and inspection.
n
Pays: |
China |
N ° de modèle: |
GCS
|
Prix FOB: |
2000 ~ 20000 / Set (Negotiable)
Obtenir le dernier prix
|
Localité: |
China |
Prix de commande minimale: |
2000 per Set |
Commande minimale: |
1 Set |
Packaging Detail: |
Wooden Packing |
Heure de livraison: |
In One Month |
Capacité de Fournir: |
500 Set per Month |
Payment Type: |
PayPal, L/C, T/T |
Groupe de produits : |
Switchgear
|