Prix FOB
Obtenir le dernier prix( Negotiable )
|1 Set Minimum Order
Pays:
China
N ° de modèle:
GC-2010D
Prix FOB:
( Negotiable )Obtenir le dernier prix
Localité:
No. 9, Instrument Industry base, lingang Industria
Prix de commande minimale:
-
Commande minimale:
1 Set
Packaging Detail:
polywood case
Heure de livraison:
30 days after payment received
Capacité de Fournir:
100 Set per Month
Payment Type:
T/T, L/C, Western Union
Groupe de produits :
Personne àcontacter Nancy
Dandong, Liaoning
GC****0D Gas Chromatograph Transformer Oil Dissolved Gas
Analyzer
GC****0D is specially designed for determination of the gas content
dissolved in the transformer oil. It consists of a packed column
injection system, two packed columns (a porous polymer column and a
carbosieve column), a methanator and three detectors (two flame
ionization detectors and a thermal conductivity
detector).
 Technical
characterics
1. Working
environment
lTemperature range: 5°C to
*5°C
lHumidity range: *5% to *0%
(non-condensing)
lPower supply: **0V ±*0%,
*0Hz
lPower consumption: less than 2
kVA
2. Column
oven
lDimension: **0 (W) x **0 (H) x **0
(D) mm
lOperating temperature: Ambient*5°C
to **0°C (increment of 1°C)
lTemperature accuracy:
0.5%
lRamp rate: 0.1~*0°C/min
(Temp ≤ **0°C); 0.1~*0°C/min (Temp >
**0°C)
lTemperature program steps: Up to *6
steps
lCooling speed: *0 minutes for **0°C
to *0°C
3. Column pressure and flow
rate
lDisplay of column pressure:
Mechanical pressure gauge (**0.4 kPa) or electrical
display
lDisplay of flow rate: Gas rotameter
(increment of 1ml/min) or electrical display
lControl of column pressure and flow
rate: Manual control with pressure regulator and
flow stabilizing valve (mass flow
controller).
ÂÂ
4.
Injection
lNumber of injection ports: up to 3
(Packed column injector or split/splitless capillary
column injector)
lCould be adapting to some commercial
automatic injector
5. Communication with
PC
lCommunication mode:
Ethernet
lHigh-performance chromatography
dataprocessing software
is employed.
lSplit/splitless temperature
parameters, and valveswitching can
be controlled by software on computer, automatically and
remotely.
6.
Detectors
Two FID detectors and a TCD detector
are installed to detector section on the top of the Model D
instrument. The detector’s technical specifications are listed as
follow:
ÂÂ
FID:
lMaximum temperature:
**9.9℃
lMinimumdetection
limit: ≤3×*0**2
g/s (n-C*6)
lLinearrange:
*06
lIgnition: automatically
TCD:
lSensitivity:
S ≥ ***0 mV•ml/mg
(n-C*6)(Amplification:
2, 4, 8)
lLinear range:
*04
ÂÂ
Pays: | China |
N ° de modèle: | GC-2010D |
Prix FOB: | ( Negotiable ) Obtenir le dernier prix |
Localité: | No. 9, Instrument Industry base, lingang Industria |
Prix de commande minimale: | - |
Commande minimale: | 1 Set |
Packaging Detail: | polywood case |
Heure de livraison: | 30 days after payment received |
Capacité de Fournir: | 100 Set per Month |
Payment Type: | T/T, L/C, Western Union |
Groupe de produits : | gas chromatograph |