Airwell+ 7 Tunable Diode Laser CH4 NH3 HCL CO2 N2O gas Analyzer By KINSCO Technology Co., ltd,
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs. Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Airwell+ 7 Tunable Diode Laser CH4 NH3 HCL CO2 N2O gas Analyzer
Next

Airwell+ 7 Tunable Diode Laser CH4 NH3 HCL CO2 N2O gas Analyzer

|

- Minimum Order

Pays:

South Korea

N ° de modèle:

-

Prix FOB:

Localité:

-

Prix de commande minimale:

-

Commande minimale:

-

Packaging Detail:

-

Heure de livraison:

-

Capacité de Fournir:

-

Payment Type:

-

Groupe de produits :

-

Contacter maintenant
1st Année

Personne à contacter Jong Duke

Nowon-gu, Seoul

Contacter maintenant

La description

1 , System Specification
General Specification
Display : High resolution : High resolution 7 inches Color Touch screen display
Operational power : **0VAC *0/*0 Hz
Data Memory : over 4 Giga Byte
2 USB ports for the data collection and External keyboard/Mouse
Bulit-in sampling pump : Sample flow rate 1~5 liter/min
Operating System Max memory 4GB, DDR3 CPU Linux OS
Slot 2, Intel chipset, High speed USB 3.0,
Graphyic (On-borad VGA D-SUB) Giga byte LAN
Operation condition of detection unit
- Important : Reference conditions, external: *0°C *3° C, **0 ****0 hPa,RH*0~*0%
Principle of detection - Tunable Diode Laser Absorption Spectrometric (TDLAS)
Wavelength (μm) : CH4 : 1.2 Range : 0~**0 ppm ,***0, ****0 ppm
NH3 : 1.5 Range : 0~**0 ppm, **0, ***0 ppm
CO2 : NDIR Range : 0~***0 ppm *0,**0%
N2O : NDIR Range : *****0 ppm
** Ranges are changeable according to the ordered specification
Displayed resolution : 0.1 ppm (negative values can also be displayed)upto **0ppm TDLAS
TDLAS Accuracy : ± 2% of reading or, ± 0.2 ppm whichever is larger
NDIR accuracy : +/- 2% of FS or 1ppm
Zero drift : over 2 h period - 2% reading
Span drift : over 8 h period - within Accuracy
Max. error on temp. comp of reading/°C : < 0.1 %
Linearity - included in the accuracy
Cross talk/interference - Gas matrix and application dependent
Ambient temp. compensate : Type A : CH4 : **0~*0 °C , NH3 & CO2 : **0~*0°C
Type H : NH3 : **0 ~*5°C
* A: For Ambient sample H: For Heated sample
Meas. gas max. humidity abs. H*0 % application dependent, needs calibration
Weight : about *0 kg, Case material : Anodized white aluminium
Dimension : *9 Inches Rack mountable / Table Top Depth **0 (mm)
Signal Analog output : ***0 mA or ***0mA( depends onf factory range set)

Pays: South Korea
N ° de modèle: -
Prix FOB: Obtenir le dernier prix
Localité: -
Prix de commande minimale: -
Commande minimale: -
Packaging Detail: -
Heure de livraison: -
Capacité de Fournir: -
Payment Type: -
Groupe de produits : -
Airwell+ 7 Tunable Diode Laser CH4 NH3 HCL CO2 N2O gas Analyzer

Mots-clés correspondants KINSCO Technology Co., ltd

Send a direct inquiry to this supplier

To:

Jong Duke < KINSCO Technology Co., ltd >

Je veux savoir: