500kW Air Cooled AC 3 Phase Resistive Load Bank for Generator UPS Power Plant Load Testing 500kW Air Cooled AC 3 Phase Resistive Load Bank for Generator UPS Power Plant Load Testing 500kW Air Cooled AC 3 Phase Resistive Load Bank for Generator UPS Power Plant Load Testing 500kW Air Cooled AC 3 Phase Resistive Load Bank for Generator UPS Power Plant Load Testing 500kW Air Cooled AC 3 Phase Resistive Load Bank for Generator UPS Power Plant Load Testing
Next

500kW Air Cooled AC 3 Phase Resistive Load Bank for Generator UPS Power Plant Load Testing

8955 ~ 11495 USD / Set

|

1 Set Minimum Order

Pays:

China

N ° de modèle:

RT500kWLB

Prix FOB:

8955 ~ 11495 USD / Set Obtenir le dernier prix

Localité:

China

Prix de commande minimale:

8955 per Set

Commande minimale:

1 Set

Packaging Detail:

Wrapping film

Heure de livraison:

25-30 days

Capacité de Fournir:

5 Set per Month

Payment Type:

L/C, T/T

Groupe de produits :

Contacter maintenant
Membre gratuit

Personne à contacter Mr. Winston

East Section of Hongyu Road, Jinshan Industrial Park, Luojiang District, Deyang City, Sichuan Provin, Deyang, Sichuan

Contacter maintenant

Spécification du produit

  • Color:RAL 7035/ Customer supply color number
  • Nominal voltage:AC380V/400V/415V/480V/690V/10.5KV/11KV/Customized
  • Nominal power:500kW
  • Frequency:50/60Hz
  • Power factor:1.0
  • Control mode:Manual/PC control(support printing)

La description

**0kW Air Cooled AC 3 Phase Resistive Load Bank for Generator UPS Power Plant Load Testing
 
Model No. RTZ***0kW***0V**0Hz/*0Hz-PF1.0
Load type **0% Resistive
Voltage AC**0V(AC**5V/**0V/**0V/OR OTHERS)
Frequency *0Hz/*0Hz
Capacity **0kW
Power factor 1.0
Control mode Two options for selection
â–  Local panel manual control: The load bank is equipped with a local control panel and is divided into several power steps, which can be loaded through switch control.
â–  Manual + PC control: control the load through the data management software on the computer,realize all test functions,display,record and manage test data,generate various curves,charts and test reports and support printing.
â–  Software language: English/or others
PC control system:
â–  I5 processing system
â–  *0m category 6 network cable
â–  Interface: RJ*5/RS**2/**5 for choice
Application environment Two options for selection

â– Indoor(IP*3)
Prevent the invasion of solid foreign objects with a diameter greater than *2.5mm (prevent human fingers from touching the parts inside the appliance, prevent the invasion of foreign objects with a diameter greater than *2.5mm), and prevent the invasion of sprayed water (prevent rain or damage caused by the invasion of water sprayed in the direction with a vertical included angle less than *0 °)

â– Outdoor(IP*5)
Prevent external objects and dust (completely prevent the invasion of foreign objects, although not completely prevent the invasion of dust, but the amount of dust invasion will not affect the normal operation of electrical appliances), and prevent the invasion of sprayed water (continuous low pressure water spray, 3 minutes)
Control voltage 3P 4 wire,AC**0V
Load accuracy ±3%
3Phase Balance Unbalance≤3%
Insulation F
Power source connection Load power source connection: copper bar
Control power source connection: terminal
 A,B,C,N Will be marked on the product.
Terminal: from left to right: A,B,C,N too.
Time rating Continuous design/temporary
 

Resistive load
Min.step: Nominal 1kw resolution or customized
Steps:1kW,2kW,2kW,5kW,*0kW,*0kW,*0kW,*0kW,**0kW*4
Customized available,for example:**0kW*5 or others choice.
Electrical performance index of finned resistor
â–  Each resistance element: insulation impedance DC***0V/*0MΩ 
â–  Withstand voltage AC ***0v for 1 minute
â–  Resistance error of each resistor: ±3%
■ Long time work under **0℃
â–  Temperature drift coefficient:±1.5%
â–  Work temperature is 1/3 of the design temperature. 
Cooling system Cooling mode: Forced ventilation,horizontal air inlet/outlet 
â–  Airflow/Fan power and air volume shall be designed according to 2 times surplus coefficient of heat loss.  
â–  Brand: first-line well-known brand at domestic and abroad
â–  Power supply mode: 3phase AC power supply.
â–  Noise:≤ *5db (3M)
â–  The fan adopts axial flow fan, aviation aluminum fan blade, decentralized air supply design, sufficient air volume, low noise, high strength, corrosion resistance, durability and other advantages of the fan blade .
Load test functions â–  Real time display of current
â–  voltage
â–  frequency
â–  power
â–  power factor
â–  electrical performance indicators
â–  curve and report output
â–  system electrical parameter monitoring
â–  automatic data acquisition
â‘  Above all functions for manual + PC control
â‘¡ Above functions marked in yellow for manual control            
Data save Manual + PC control: table saved by excel,curve save by word.Support printing.
Load protection/function â–  Low air volume: when the air volume of any fan is insufficient, it will automatically unload and alarm.
â–  High temperature: automatically unload and alarm when the load temperature exceeds the safety threshold.
â–  Over voltage: it will automatically unload and alarm when the load voltage exceeds the safety threshold.
â–  Fan interlock protection: the load cannot be loaded before the fan power switch is turned on.
â–  Short circuit/over current: the load circuit is equipped with a fuse to avoid damage to the equipment in case of load short circuit or excessive current.  
â–  Emergency stop: manual one forced unloading is available, and it cannot be loaded under emergency stop locking status.
â–  Fan phase sequence automatic transfer protection: when the control power line is not connected according to the correct phase sequence, the three-phase fan can also operate in the normal direction.
â–  Protection switch: some protection functions are equipped with switches, and corresponding protection functions can be temporarily turned off in case of false alarm or special needs.
â–  Grounding protection: in order to avoid electrification of the chassis and electric shock hazard, the load cabinet is equipped with special grounding protection terminals.
â–  Operational indicator: indicates whether the device can be put into load, and the indicator light on indicates that the device is in normal state and can be put into load.
â–  Fan operation indicator: indicates whether the fan of the device is running, and the corresponding indicator light for fan startup is on.
â–  Load switch: the control device is to switch on or off the load, and jog the switch to switch on the selected load.
Cabinet color RAL***5 /Customized(supply the color number,for example RAL***8). 
Transportation Lifting hole/ Castors / Forklift hole 
Size/Weight ***0****0****0(mm)  / **0kg

Pays: China
N ° de modèle: RT500kWLB
Prix FOB: 8955 ~ 11495 / Set Obtenir le dernier prix
Localité: China
Prix de commande minimale: 8955 per Set
Commande minimale: 1 Set
Packaging Detail: Wrapping film
Heure de livraison: 25-30 days
Capacité de Fournir: 5 Set per Month
Payment Type: L/C, T/T
Groupe de produits : Resistive Load Bank