375KVA/300kW/225kvar Air Cooled AC 3 Phase Resistive Inductive Load Bank for Generator UPS Power Plant Load Testing By Deyang Rata Technology Co., Ltd,
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs. Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
375KVA/300kW/225kvar Air Cooled AC 3 Phase Resistive Inductive Load Bank for Generator UPS Power Plant Load Testing 375KVA/300kW/225kvar Air Cooled AC 3 Phase Resistive Inductive Load Bank for Generator UPS Power Plant Load Testing 375KVA/300kW/225kvar Air Cooled AC 3 Phase Resistive Inductive Load Bank for Generator UPS Power Plant Load Testing
Next

375KVA/300kW/225kvar Air Cooled AC 3 Phase Resistive Inductive Load Bank for Generator UPS Power Plant Load Testing

18656 ~ 21195 USD / Set

|

1 Set Minimum Order

Pays:

China

N ° de modèle:

RT375KVALB

Prix FOB:

18656 ~ 21195 USD / Set Obtenir le dernier prix

Localité:

China

Prix de commande minimale:

18656 per Set

Commande minimale:

1 Set

Packaging Detail:

Wrapping film

Heure de livraison:

25-30 days

Capacité de Fournir:

5 Set per Month

Payment Type:

L/C, T/T

Groupe de produits :

Contacter maintenant
Membre gratuit

Personne à contacter Mr. Winston

East Section of Hongyu Road, Jinshan Industrial Park, Luojiang District, Deyang City, Sichuan Provin, Deyang, Sichuan

Contacter maintenant

Spécification du produit

  • Color:RAL7035/ Customer supply color number
  • Nominal voltage:AC380V/400V/415V/480V/690V/10.5KV/11KV/Customized
  • Nominal power:375KVA/300kW/225kvar
  • Frequency:50/60Hz
  • Power factor:0.8 or others
  • Control mode:Manual/PC control(support printing)

La description

**5KVA/**0kW/**5kvar Air Cooled AC 3 Phase Resistive Load Bank for Generator UPS Power Plant Load Testing

 













































































































































 
Resistive Inductive Load Bank Data Sheet
Model No. RTZG-**5kVA***5V**0Hz/*0Hz-PF0.8
Load type Resistive+inductive
Voltage AC**5V/3 phase
Frequency *0Hz/*0Hz
Capacity **5kVA/3*0KW/**5Kvar
Power factor 0.8
Control mode 1,Local panel manual control: The load bank is equipped with a local control panel and is divided into several power steps, which can be loaded through switch control.

2, Manual+remote PC control(automatic) both can be operational.(There is manual/Auto switch,and when you use PC to operate,the manual can not operate and vice versa.

PC control system:

1: Computer: I5 processing system

2: Network cable: *0m over Category 6 network cable

3: Software control system

4: communication interface:RJ*5/RS**2/RS**5can be selected.
Application environment Indoor(IP*3)

Outdoor(IP*4)
Control voltage Power source: 3 phase 4 wire,AC**5V
Load accuracy ±3%
3Phase Balance Unbalance≤3%
Insulation F
Load power source connection Copper bar
Control power source connection Terminal 
Time rating Continuous design/temporary.
 

Resistive load
Min.step: 1kW

Steps: 1kW,2kW,2kW,5kW,*0kW,*0kW,*0kW,*0kW,**0kW,**0kW*2.

The steps can be designed based on customers requirement.
Electrical performance index of Resistor:

1,Each resistance element: insulation impedance DC2**0V/*0MΩ 

2,Withstand voltageAC***0v for1minute

3,Resistance error of eachresistor: ±3%

4, Long time work under **0℃

5, Temperature drift coefficient:±1.5%

6, Work temperature is 1/3 of the design temperature. 
Inductive load Min.step: 0.*5kvar.

Steps: 0.*5kvar,1.5kvar,1.5kvar,3.*5kvar,7.5kvar,7.5kvar,*5kvar,*7.5kvar,*5kvar*2.

The steps can be designed based on customers requirement.
1. Insulation impedance: DC/***0V/5MΩ

2. Withstand voltage: AC ***0v for 1min

3. Resistance error of each resistance: 1.5%~± 3% 
Cooling system Cooling mode: air cooled,horizontal air inlet/air outlet
Air volume shall be designed according to 2 times surplus coefficient of heat loss.
Load test function 1, Current

2, Voltage

3, Frequency

4, Power 

5, Power factor
 

6, Electrical performance indicators

7, Curve and report output

8, System electrical parameter monitoring

9, Automatic data acquisition

A: Above all for PC control

B: Above first 5 for manual control
Data save Manual + PC control: table saved by EXCELL,curve save by word. Support printing. 
Load protection 1, Low air volume

2, High temperature

3, Over pressure

4, Over current

5, Short circuit

6, Emergency stop
Cabinet color RAL ***5 or customer supply the color number.
Transportation Lifting hole/castors/forklifting hole
Dimension(L*W*H) ≈***0mm****0mm****0mm
Weight ≈***0kg
Packing Wrapped film
Work Environment
Temperature **0ºC to *0ºC
Humidity up to **0%
Altitude up to ***0m
Atmospheric pressure *6 to **6kPa
Other main parts Contactor/Circuit breaker: ABB/SCHNEIDER 

Pays: China
N ° de modèle: RT375KVALB
Prix FOB: 18656 ~ 21195 / Set Obtenir le dernier prix
Localité: China
Prix de commande minimale: 18656 per Set
Commande minimale: 1 Set
Packaging Detail: Wrapping film
Heure de livraison: 25-30 days
Capacité de Fournir: 5 Set per Month
Payment Type: L/C, T/T
Groupe de produits : Resistive Inductive Load Bank

Send a direct inquiry to this supplier

To:

Mr. Winston < Deyang Rata Technology Co., Ltd >

Je veux savoir: