Sell Singclean Interleukin-6 (IL-6) Test Kit to Help Detect Inflammation and Disease Prevention By Hangzhou Singclean Medical Products Co., Ltd., China
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs.
Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell Singclean Interleukin-6 (IL-6) Test Kit to Help Detect Inflammation and Disease Prevention

Sell Singclean Interleukin-6 (IL-6) Test Kit to Help Detect Inflammation and Disease Prevention

3 ~ 5 / Piece ( Negotiable )

|

Minimum Order

Localité:

-

Prix de commande minimale:

Commande minimale:

200 Piece

Packaging Detail:

12pcs/box

Delivery Time:

1-30days

Supplying Ability:

10000 Piece per Day

Payment Type:

T/T, Western Union, PayPal

Contacter maintenant
4th Année

Personne à contacter peter123-cn.baiyh.030742

Hangzhou, Zhejiang

Contacter maintenant

Description

Product Description

Introduction

Interleukin*6 is mainly produced by Th2 cells and secreted by T lymphocytes, B lymphocytes, fibroblasts, endothelial cells, keratinocytes, hepatocytes and bone marrow cells. Its relative molecular weight is *6kDa. It is a glycoprotein composed of **2 amino acid residues. Interleukin*6 is the first biomarker to appear after inflammatory reaction. In different inflammatory diseases, the content of interleukin*6 is significantly different. The increased level of interleukin*6 caused by bacterial infection is significantly higher than that caused by non-bacterial infection, and the level of interleukin*6 is directly proportional to the severity of inflammation and infection. Interleukin*6 is also a sensitive early warning index of sepsis, and has a good correlation with the severity and prognosis of sepsis. As an inflammatory factor, the level of interleukin*6 is also closely related to cardiovascular and cerebrovascular diseases such as atherosclerosis and acute myocardial infarction (AMI).

Indications for Use
The kit is used for quantitative determination of interleukin*6 (IL*6) in human serum, plasma or whole blood samples in vitro.

Who Should Have the Interleukin*6 (IL*6) Test?
Patients suffering from inflammatory conditions;Patients with diabetes, stroke or with cardiovascular disease and C***-infected patients. Interleukin*6 (IL*6) may be used to help evaluate a person who has a condition associated with inflammation, such as lupus or rheumatoid arthritis, or with infection, such as sepsis. It may also be used in the evaluation of diabetes, stroke, or cardiovascular disease.
Besides, Interleukin*6 (IL*6) Test Kit can help determine the risk of developing severe coagulation-related consequences such as disseminated intravascular coagulation (DIC) and acute respiratory distress syndrome (ARDS) in severe cases of C**9 infection.
Combined with the highly specific PCT joint inspection, it can early warning of sepsis, reflect the severity of infection, evaluate the treatment effect, and help the clinic to quickly judge the patient\'s situation


Features&Benefits

Accurate: the fluorescence immunochromatography method based test kit has higher accuracy.
Easier to read: based on fluorescence immunochromatography, easier to read test result than colloidal gold immunochromatography.
Easy for storage: it can be stored at room temperature (4ºC~*0ºC).
Longer validity period: *8 months of validity period.


 

Product Performance Index
a) Accuracy:When tested with standard IL*6, the relative deviation (B%) between the detection mean value and the target value shall be within Â± *5%.
b) Linear range: The linear range is 7pg / ml ~ ***0pg / ml, and the linear correlation coefficient r≥0.***0.
c) Blank limit: not higher than 7ng/mL;
d) Precision:
In-batch precision: The coefficient of variation (CV) is not more than *5%;
Precision between batches: The relative range between batches is not more than *5%.


Product Information
Product Name Interleukin*6 (IL*6) Test Kit (Fluorescence Immunochromatography)
Method Fluorescence immunochromatography
Specimen Whole blood, Plasma, Serum
Specification *0 tests/box, *0 tests/box, *5 tests/box, *0 tests/box, *0 tests/box, **0 tests/box.
Components Each pouch contains a test card and a desiccant; the test card is composed of a shell and a test strip, the test strip is composed of sample pad, fluorescent pad (fixed with fluorescent labeled IL*6 monoclonal antibody 1), nitrocellulose membrane (coated with IL*6 monoclonal antibody 2 and goat anti-mouse IgG), filter paper and PVC plastic plate
Test time *5 mins
[Applicable instrument]
Fluorescence immunoassay analyzer
It should be purchased separately and can be used for different Test Items, like CK-MB, IL6, PCT.
For different tests, scan the QR code accordingly.



Test Procedure
Please read the instructions of the test kit and the manual of the fluorescence immunoanalyzer carefully before use.
a) Bring the test kit and sample to be tested to room temperature.
b) Make sure the ID card matches the batch number of the kit, and insert the ID card into the card reading area of the instrument to read the information.
c) Open the inner package of the test card, take out the test card; draw *5μL of serum plasma sample, drop vertically to the test card sampling place, and start timing; draw *5μL whole blood, vertically drop it to the test card sampling place, and immediately add 1 drop whole blood diluent at the sampling place and start timing.
d) After adding the sample, click "Start Test" on the screen of the fluorescence immunoanalyzer, and the test card will react at room temperature for *5 minutes; insert the test card into the test card slot of the fluorescence immunoanalyzer, and the instrument will automatically test the test card; The test results can be seen on the display screen of the immunoassay analyzer. Click "Print" on the screen to print the results.


Positive Judgment Value or Reference Interval
Normal reference value:<7pg/mL.
Due to differences in geography, race, gender and age, it is recommended that each laboratory establish its own positive judgment value or reference interval.
 

Test result

(For reference only, not used as clinical diagnostic criteria, test results need to be combined with other clinical and laboratory data for clinical diagnosis)

Content of IL*6(pg/mL) Clinical application suggestions
<7 Normal value
****0 Indicates mild inflammation or mild infection.
******0 Suggests general bacterial infection or systemic inflammatory reaction.
>**0 Suggests may be sepsis.


Limitations
a) This test kit is only for the test of human serum, plasma or whole blood samples. Abnormal hematocrit samples have an impact on the results of the whole blood test. The test results of serum, plasma and whole blood are not significant difference when the hematocrit is between *1% and *8%.
b) The test results need to be combined with other clinical and laboratory data, and if the IL*6 test results do not match the clinical assessment, further testing is required.
c) False positive results can be caused by: cross-reaction of antibody-like components in the blood; some non-specific components in blood have similar antigenic determinants to capture fluorescent-labeled antibodies, such as anisotropic antibodies and rheumatoid factors. In view of the above reasons, the test results should be combined with the patient\'s medical history and other laboratory results performed.
d) Hemoglobin, triglycerides and bilirubin in the blood sample can interfere with the test results, where the maximum allowable concentrations are 5g/L, *0g/L and 0.2g/L, respectively.
e) False positive results can be caused by: some unknown components shield the antigenic determinants from binding to the antibody; the unstable IL*6 antigen gradually degrades with time and temperature and cannot be recognized by the antibody. Valid test results depend on a good reagent and sample storage environment.
f) Other factors, including technical reasons, operational errors and other sample factors, may also cause errors in test results.

Certificate
CE      ISO****5

Sell Singclean Interleukin-6 (IL-6) Test Kit to Help Detect Inflammation and Disease Prevention

Send a direct inquiry to this supplier

To:

peter123-cn.baiyh.030742 < Hangzhou Singclean Medical Products Co., Ltd. >

Je veux savoir: