Cables for submersible electric pumps (ESP) - temperature index of 120 degrees By Petroleum Engineering Systems, LLC, Russia
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs.
Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Cables for submersible electric pumps (ESP) - temperature index of 120 degrees

Cables for submersible electric pumps (ESP) - temperature index of 120 degrees

( Negotiable )

|

Minimum Order

Localit:

-

Prix de commande minimale:

-

Commande minimale:

-

Packaging Detail:

-

Delivery Time:

-

Supplying Ability:

-

Payment Type:

-

Contacter maintenant
Membre gratuit

Personne à contacter Mr. Igor

STROITELEI, PERM, PERM KRAI

Contacter maintenant

Description

Cables with three main conductors made of thermo-corrosion-resistant aluminum alloy (TAC) with two-layer insulation made of polymeric materials for submersible electric pump installations are designed to supply electrical energy to electric motors of an oil production unit for a nominal voltage of 3.3 and 4.0 kV with an operating frequency range of **- **0 Hz.
The long-term permissible heating temperature of the cable cores is **0 ° C.

PRODUCT ADVANTAGES
Reducing weight
Lower cost
Increased flexibility
Increased wear resistance
The shield retains its shape
Flame retardant
Double bandwidth

Main characteristics:

Operating temperature range of cables, [° С] ..- *0 to ***0
Installation at temperature, [° С] .. not lower than **0
Average service life of cables, [year] .. 5.5
Shelf life, [months] *2 from the date of receipt to the day of putting the cable into operation
Warranty period for cables, [months] .. *4
Crushing load . .not less than **8 kN (*6,**0 kgf)
DC test voltage, kV
- for cable 3.3 kV ..eighteen
- for cable 4.0 kV .. *2
Leakage current at test voltage, no more, [A] .. 0.5 * ***5
DC test voltage when checking cables operated in wells, [kV] .. no more than *2
 

          Cables are designed for operation in wellbore fluid containing
oil, as well as water and gas, with the following indicators:

Water content - up to **0%.
The pH of the associated water is pH 5.*8.5.
A short-term (up to 6 hours) decrease in pH is allowed - to 0.
Hydrogen sulfide concentration,% (g / l), no more:
- 0.**1 (0.*1) - for cables with armor made of galvanized steel tape;
- 0.**5 (1.*5) - for cables with armor made of stainless steel corrosion-resistant tape.
Hydrostatic pressure - no more than *0 MPa.
Gas factor in the environment - no restrictions.
 
Cable Installation Requirements:

The ascent of the cable from the well and the descent should be carried out smoothly, at a speed of no more than 0.*5 m / s. When passing sections of the well pipe string with a curvature of more than 1.5 ° by *0 m and transition points to a smaller diameter, the lifting and lowering speed should not be more than 0.1 m / s. When fastening to tubing and screwing pipes, twisting of the cable around them, as well as twisting of a flat cable relative to its own axis, is not allowed. To reduce the shrinkage of the ends of the insulation, in order to improve the quality of the splices, it is recommended to heat the ends of the insulated conductors.