FOB Price
Obtenir le dernier prix50 ~ 70 / Kilogram ( Negotiable )
|Minimum Order
Localité:
-
Prix de commande minimale:
Commande minimale:
300 Kilogram
Packaging Detail:
25kg carton drum or 1kg foil bag or by request of clients
Delivery Time:
14 working days
Supplying Ability:
1000 Kilogram per Week
Payment Type:
T/T, Western Union, Money Gram
South Africa
Personne àcontacter Mr. Glein
No. 15, 14th Ave, Vosterkroom, Nigel, Gauteng
Food additive anhydrous lactose
Test items | Criterion | Results | ||||
Identification A | The infrared absorption spectrum of the sample is concordant with that of the standard. | The infrared absorption spectrum of the sample was concordant with that of the standard. | ||||
Identification B | The principal spot obtained from the Test solution corresponds in appearance and RF value to that obtained from Standard solution A. | The principal spot obtained from the Test solution corresponds in appearance and RF value to that obtained from Standard solution A. | ||||
The test is not valid unless the chromatogram obtained with Standard solution B shows four clearly discernible spots, disregarding any spots at the origin. | Standard solution B shows four clearly discernible spots. | |||||
Identification C | A red color develops. | It appeared red color. | ||||
Specific rotation | **4.4°~**5.9°, calculate on the anhydrous basis. | **5.0° | ||||
Acidity or alkalinity | Add 0.3ml of phenolphthalein TS: the solution is colorless, and not more than 0.4 ml of 0.1 N sodium hydroxide is required to produce a red color. | Add 0.3ml of phenolphthalein TS: the solution was colorless, and not more than 0.4 ml of 0.1 N sodium hydroxide was required to produce a red color. | ||||
Water | Not more than 1.0% | 0.5% | ||||
Residue on ignition | Not more than 0.1% | 0.*4% | ||||
Heavy metals | The limit is 5µg per g. | Less than 5µg per g. | ||||
Protein and light-absorbing impurities | The absorbance divided by the path length in centimeters is not more than 0.*5 in the range of **0 to **0nm and is not more than 0.*7 in the range of **0 to **0nm. | The absorbance divided by the path length in centimeters was not more than 0.*5 in the range of **0 to **0nm and was not more than 0.*7 in the range of **0 to **0nm. | ||||
TPC | <**0cfu/g | < *0cfu/g | ||||
Yeast & Mould | <*0cfu/g | < *5cfu/g | ||||
Escherichia coli (/*0g) | absence | Not detected | ||||
Conclusion : | The Quality of lactose product has the achieved scandard of USP*0 after examination standard examination, and consequently meet the provision. |