EXPLOSION-PROOF ELECTRICAL CONTACTS By Re-Atlantis Enterprise Co., Ltd., Taiwan
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs. Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
EXPLOSION-PROOF ELECTRICAL CONTACTS

EXPLOSION-PROOF ELECTRICAL CONTACTS

( Negotiable )

|

Minimum Order

Localit:

-

Prix de commande minimale:

-

Commande minimale:

1 Piece

Packaging Detail:

-

Delivery Time:

-

Supplying Ability:

-

Payment Type:

T/T, L/C, Other

Contacter maintenant
Membre gratuit

Personne à contacter Ms. Mini

1F, No.109, Sec.2, Zhiyuan 1st Rd., Beitou District, Taipei, Taiwan (R.O.C.) 11289, Taipei, Taiwan

Contacter maintenant

Description

EXPLOSION-PROOF ELECTRICAL CONTACTS
Inductive type-ECI series

APPLICATIONS

The electrical contacts are fitted into the case of pressure gauges and intended to make or break an electric control circuit to the position of the pointer on the instruments. 

DISCRIPTIONS
The pressure gauge with explosion-proof inductive is inductive approach form, because of non-contact-type, it has no any spoilage to the power supply system. Without electric spark, long using life, little impact on the measurement accuracy, it is not only applicable to certain dangerous places, but also suitable for frequent turn on/off occasions. 
ECI series explosion-proof inductive pressure gauge is based on GB***6.1 (the request of the electric equipment used in explosive gas environment) and GB***6.4 (safe explosive gas environment electrical equipment intrinsically safety-type 1).

SPECIFICATIONS
* Instruments
All Stainless Steel series pressure gauges of dial Φ4 & 6
* Position of Contact Block
Hiding type - the contact block is mounted behind the dial 
* Number of Contacts
Single contact-normally open;normally closed
Double contacts-normally open and closed;normally open x 2;normally closed x 2
* Protection Class
Standard type - IP*4
Airtight type or Liquid filled type - IP*5
* Explosion-proof class
Exib II CT6

* Lens
Safety glass
* Wiring styles
by Junction box
* Filling (option)
Insulation oil
* Electrical Parameter
Pressure gauge fixed: 8 VDC, Safe voltage <*6 VDC
Working current: opening ≧3mA, Closed ≦1mA, Safe current <*2 mA
On/off frequency <***0 Hz
* Pressure Range
0/1 to **0 kg/cm2 ( bar)ï¼›0/*0 to ***0 mbar
positive, negative or compound range available 
 

Send a direct inquiry to this supplier

To:

Ms. Mini < Re-Atlantis Enterprise Co., Ltd. >

Je veux savoir: