FOB Price
Obtenir le dernier prix169 ~ 179 / Piece ( Negotiable )
|Minimum Order
Localité:
-
Prix de commande minimale:
Commande minimale:
1 Piece
Packaging Detail:
neutral packing
Delivery Time:
5~7days for small order
Supplying Ability:
10000 Piece per Month
Payment Type:
T/T, Western Union, PayPal
Personne àcontacter Ms. Jenny
Shenzhen, Guangdong
General Descriptions
Conventional
Reflective Beam Detector (hereinafter
called the detector) is a non-addressable
reflective infrared beam
smoke detector is
applicable to historical
buildings, warehouses,
large storages,
shopping malls, leisure centers,
exhibition halls, hotel lobbies, printing houses,
clothing factories, museums and prisons etc, as
well as places where slight smoke particles
exist.
Features
(1) Wide operating voltage range, big monitoring areas.
(2) Combination of the emitting and receiving part makes mounting easy and optical pathway accurate.
(3) Built-in microprocessor enables intelligent judgment of fire alarm and fault.
(4) The detector can calibrate automatically, which ensures that one person complete adjustment in short time. Its also convenient to operate.
(5) Self-diagnosis function can monitor the inner fault.
(6) Automatic compensation for factors weakening received signals, such as dust contamination, positional excursion and ageing transmitter.
(7) It has passive output contacts for fire alarm and fault.
(8) Two sensitivity levels can be set in field.
(9) The detectors optical pathway is designed with strong anti-interference ability.
(*0) SMT processing technology.
(*1) Attractive and decent appearance.
Technical Specifications
(1) PowerVoltage:*5VDC**8VDC
(2) Power Current: Commissioncurrent*0mAStandbycurrent*2mA Alarm current*2mA
(3) FireAlarm and Fault Contact Output
FireAlarmRelay:Contactcapacity*8V/2A,whichisnormallyopeninnormalstate
and closed in fire alarm state.
Fault Relay: Contact capacity *8V/2A, which is normally open in
normal state and closed in fault state.
(4)
Angle of Adjusting: *6°-*6°
(5) Dependency Angle of Optical Pathway Orientation:
0.5¢
(6) Sensitivity Level:
Level 1: High sensitivity. Level 2: Medium sensitivity.
(7) Indication of Detector State:
(8)
Operating Environment: Temperature: **0°C-**0°C
Relative Humidity *5%, non condensing
(9) Monitoring Area: aximum monitoring area:
*4***0=***0m2
Maximum width: *4m
(*0) Length of Optical Pathway: 8m***0m
(*1) Protection Level:
Under common environment, ingress protection rating is IP*0.
Under special environment, ingress
protection rating is IP*6 through
glue-seal treatment.
(*2) Dimension: length: **6mm width: *5mm thickness: *5mm
(*3) Material and Color of Enclosure: ABS, gray
(*4) Weight: **0g
(*5) Mounting Hole Spacing: Spacing for embedding: **8mm
Spacings for surface mounting: *9mm€*6mm