Single-phase medical isolation transformer By Shenzhen Wapower Electrical Technology Co., Lt, China
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs. Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Single-phase medical isolation transformer

Single-phase medical isolation transformer

10 ~ 15000 / Piece ( Negotiable )

|

Minimum Order

Localité:

-

Prix de commande minimale:

Commande minimale:

1 Piece

Packaging Detail:

in wooden cases

Delivery Time:

2-3 weeks

Supplying Ability:

5000 Piece per Month

Payment Type:

T/T

Contacter maintenant
Membre gratuit

Personne à contacter Ms. becky

Shajing, Shenzhen, Guangdong

Contacter maintenant

Description

Product introduction
Single-phase medical isolation transformer
 provides power for single-phase IT system, with the static shielding is installed between the primary winding and secondary windingThis transformer is seamlessly rolled by high quality cold rolled silicon steel strip and characterized by low iron loss, good thermal diffusivity of winding, low temperature rise, good uniformity of winding, low magnetic interference, etc. It is specially used for medical and high standard special facilities. And there is a built-in high precision temperature probe whose data can be uploaded in synchronization with that of insulation monitor and other equipments.



The characteristics of medical isolation transformer at the input end of the AC power supply:
1. Eliminating third harmonic and the third harmonic of more serious interfering signals on the power grid, and reducing interfering signals.
2. Producing new neutral conductor and preventing the equipment from working abnormally due to bad neutral line on the power network.
3. Isolating the current waveform distortion caused by non-linear load (such as third harmonic) without polluting the power grid.



The characteristics of medical isolation transformer at the output end of the AC power supply:
1. Preventing the non-linear load current distortion from affecting the normal working of AC power supply and polluting the power grid to improve the quality of power network.
2. Preventing the non-linear load current distortion from affecting the precision of sampling at the input end of the isolation transformer to gain controlling signal which can reflect the actual situation.
3. Without affecting the normal working of regulated power supply in the situation of unbalanced load.


Technical parameters:
1. Rated power: 6.3 KVA, 8 KVA, *0 KVA
2. Primary voltage **0V, secondary voltage **0V
3. Working frequency: *0/*0Hz
4. No-load current < 2A
5. Full-load temperature rise < **5K
6. Insulation class: H.
7. Medical leakage current < *0uA
8. Noise level < *5db
9. Insulation resistance: DC**0V;**0MΩ MIN
*0. Protection grade: IPOO
Application environment and conditions:
1, The altitude is not more than ***0 meters and if more than ***0 meters, derating is required.
2, Running temperature: *5 ℃ - *0 ℃, relative humidity is less than *0%. 
3, Without harmful gas, inflammable, explosive and conductive dust around.