8 Inch 6-parameter Patient Monitor

8 Inch 6-parameter Patient Monitor

|

Minimum Order

Localit:

-

Prix de commande minimale:

-

Commande minimale:

-

Packaging Detail:

-

Delivery Time:

-

Supplying Ability:

-

Payment Type:

-

Contacter maintenant
Membre gratuit

Personne à contacter Ms. zhou

xinhua, yinchuan, Ningxia

Contacter maintenant

Description

Features:
Ergonomicdesign portable convenient for use
Unique digitalSPO2 technology can work accurate during motion and low perfusion
Anti AC &high-frequency electrosurgical & defibrillators interference
Rich screen layout,standard, large font, trend graph, ECG full lead ,SPO2, NIBP, RESP, TEMP, PR, and others
Strong datastorage for later review
Audible& visual alarm available, adjustable
Patientinformation management function
Powerful softwarefunction to support use in NICU, ICU, OR, CCU or normal patient room
Wired/wirelessnetworking with central monitoring system, up to *4 beds in one group
Built-in thermalrecorder for printing real-time and historical data
Super long liferechargeable Lithium battery upto 2 hours of working time
Suitable foradult, pediatrics and neonate patients
Standard configuration:           
ECG, NIBP, SPO2,TEMP, RESP, PR, Rechargeable Lithium battery
Optional:           
Dual TEMP
Dual IBP
ETCO2 (sidestream)
Wall mount
Trolley
Specification:
ECG
Full lead: I, II,III, AVL, AVR, AVF and V
Gain: 5mm/mV,*0mm/mV, *5mm/mV, *0mm/mV and *5mm/mV
Scanning speed:Changeable with three grades of *2.5mm/s, *5mm/s and *0mm/s
Band width:0.*5Hz***0Hz(3dB)
Heart rate: 
Scope: *5times/minute to **0 times/minutes
Accuracy:  ±1 time/minute
Variation of heartbeat LORENZE drawing:
Analysis on heartbeat data for the current 5 minutes with histogram during RR period. 
Arrhythmia:
Twenty kinds of common abnormal ECG can beanalyzed,
with ECG data of***0 times of arrhythmia kept and with *0 seconds kept for each time.   
Accuracy: Errorrate < *0%         </span>
Undetected rate< *0% </span>
ST section 
Scope:     ±0.8mV
Precision :  < ±0.*5mV
SpO2
 
Detectionscope:   0%***0%
Accuracy         ±1%    *0%***0%               
                 ±2%      *0%**9% 
NIBP
Theory Electricoscillator 
Cuff gassingtime   less than *5 seconds
First-time gassingpressure: dynamic state *4kPa(**0 mmHg)
Manual selection:9.3kPa(*0 mmHg),*3.3kPa(**0 mmHg),*6.0kPa(**0 mmHg)
*8.6kPa(**0 mmHg),*0.0kPa(**0 mmHg),*1.3kPa(**0 mmHg),
Automaticdetection period: 1 minute to **0 minutes 
Stop size:1 min(1 min **0min), 5min(*0min **0min), *0min(*0 min **0min) and*0min(*0 min ***0min)
Detectionscope: 
Systolic bloodpressure:   4kPa **4kPa(*0mmHg ***5mmHg)
Diastolicpressure             2kPa **9.3kPa(*5mmHg***0mmHg)
Mean pressure               2.7kPa~*1.3kPa       (*0mmHg~**5mmHg)
Detectionaccuracy 
Static pressure:±3mmHg
Pulse rate:  ±2%
Resp
Chest impedancemethod or concentration of carbon dioxide at end of respiration 
Scope of chestimpedance method     0 time/minute  **0minutes/minute 
Precision of chestimpedance method  time/minute 
Detection scope ofcarbon oxygen at end of respiration 3mmHg**5mmHg;0.4%vol*9.9%vol
Detection scope ofrespiration rate: 2 times/minute ->*0 times/minute(including baby)
Detectionprecision of respiration rate: ±1 time/minute
Temp
Single/doublepath 
Type:    Vascular/surface temperature 
Scope:    *0℃~*0℃
Accuracy:  ±0.2℃
Invasive bloodpressure (optional)
Single/doublepath 
Type: direct andcontinuous detection 
Scope:*6.*7kPa(**0mmHg)—*6.*7kPa(**0mmHg)
Precision: below *3.*3kPa(**0mmHg)±0.*7kPa(2mmHg)  *3.*3k
Pa(**0mmHg) above±2%
Frequency response:DC**2Hz
Input resistance:not less than **0kΩ
Sensitivity ofsensor: 5μV/V/mmHg
Motivation voltage:5V (DC)
Accuracy ofsensor: ±2%Isolationvoltage: 4 kV