Sell Medium Voltage Circuit Breaker By Bill International Co., Ltd, Hong Kong
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs. Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell Medium Voltage Circuit Breaker

Sell Medium Voltage Circuit Breaker

( Negotiable )

|

Minimum Order

Localité:

China

Prix de commande minimale:

-

Commande minimale:

1000 Piece

Packaging Detail:

wooden-box

Delivery Time:

5-15 days uopon your quantity

Supplying Ability:

100000 Piece per Day

Payment Type:

T/T, L/C, Western Union

Contacter maintenant
Membre gratuit

Personne à contacter Mr. Derek

Rooms 05-15, 13A/F., South Tower, World Finance Centre, Harbour City, 17 Canton Road, Tsim Sha Tsui,, Kowloon

Contacter maintenant

Description

A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by overload or short circuit.

Specifications

 

New type elcb, Suitable for a line of AC*0Hz/*0Hz, rated voltage up to **0V, rated current *6A to **0A 

 
Application 

FZM1L series earth leakage circuit breaker are one of the new type earth leakage breakers which have been developed by the company using international advanced design and manufacturing technology. Suitable for a line of AC*0Hz/*0Hz, rated voltage up to **0V, rated current *6A to **0A. and is acted as infrequent changeover of circuit or infrequent starting of motor. The breaker has overload, shortcircuit and undervoltage protective function, which can protect the circuit and the power equipment against damage, meanwhile, it can provide protection to these fire dangers that caused by these longtime existed grounding fault that can not be detected by the overcurrent protection. 
This breaker can be installed vertically(upright) or horizontally(transverse).
Wiring of the breaker can not be in adverse direction, that means power supply line must be connected to terminal 1,3 and 5,and the load line connected to terminal 2,4 and 6. 
The rated residual operating current In and the maximum breaking time can be adjusted on site according to practical condition. 
The leakage protection module still can work normally when the phase voltage reduce to *0V. It has the same overall size with the AM1 series breakers, which make the installation more exchangeable. 
The breakers are suitable for isolation, its symbol are: 
The breakers comply with the demands of the following standards:
IEC*****1 and GB/T ****8.1 General
IEC*****2 and GB ****8.2 Low voltage breakers
IEC*****4 and GB ****8.4 Contactors and motor starters
IEC*****5.1 and GB ****8.5 Electrical equipments of electromechanical control circuit 

Main Technical Specifications 
 
Type AM1L**0 AM1L**5 AM1L**0 AM1L**0
Frame Current Inm(A) **0 **5 **0 **0
Rated current In(A) (*0)*6,*0,*5,*2,*0,*0,*3,*0,**0 **0,**5,**0,**0,**0,**5 **5,**0,**5,**0,**0 **0,**0,**0
Pole Number 3 4 3 4 3 4 3 4
Rated Insulation Voltage Ui(V)   AC**0  
Rated Working voltage Ue(V)   AC **0V  
Rated impulse with stand voltage Uimp(V)   ***0  
Arcover Distance(mm)   >*0  
Breaking capacity grade M H   M H   M   M  
Limiting shortcircuit breaking capacity lcu (kA) AC**0V *0 *5 *0 *0 *5 *0 *5 *5
Service shortcircuit breaking capacity lcs(kA) AC**0V *5 *0 *5 *5 *0 *5 *2 *2
Rated residual operating current In(mA) Nondelay type   **0/**0/**0  
Delay type   **0/**0/**0 **0/**0/***0
Rated residual nonoperatingcurrent I no(mA)   1/2 In  
Operation performance (time) Electrified ***0 ***0 ***0 ***0
Unelectrified ***0