AES-LASER96, the laser skin treatment device
treatment principle is that using the Laser selective and adjusting
Q-principle laser Blasting, making the precise dose of a specific
wavelength of energy aim at a particular structor in a very short
period of time---colorradical: derma and epidermis of ink, carbon
particles and other exogenous and endogenous pigment granules of
melanin pigment cells. Pigment be heated suddenly then occur
blasting, the pigment was crushed to become smaller fragments, the
crushed fragments was phagocytosed by macrophages, with the
macrophage cells goes into the lymphatic circulation then pigment
is excreted.
The Main Technical Specifications, Performance
index:
Work
condition
Environment tempreture:10~30℃;
Relative humidity:≤75%;
atmospheric pressure:860~1060hpa;
Power supply:AC220V,50Hz;
Cooling water:deionized water or distilled water
Basic Parameter:
Physical demension(L×W×H,mm):400×380×800
Total weight:25kg;
Consumed power:600W;
creepage protectingrated current
Laser output method:Pulse adjusting Q
working Laser wavelength:1064nm;532nm
Laser pulse wideth:8ns±2ns;
Output frequency:1Hzã€2Hzã€3hz 4hz 5Hzï¼›6hz
Single pulse max output energy:100-2000mJ;
Harmed eyes distance:NOHD 1km,operated in dense need wear
eyeshield!
cooling method:Inlay closed cirlced water
Run Mode:Dwell load-on continuious running
Flare continuious adjusted
Photoelectricity
Capability,
Arthrosis bottom Output Max Single Pulse energy≥500mJ;
Laser Output enstablity:ST≤±10%;
Output Power reappear:Rp≤±10%;
Output Power and Preset valueshowing error:≤±20%;
Operation FlareDiameter:1ï¼4mm continious adjusting;
Aimming at Laser outputpower Pc::0.1mW≤Pc≤5mW
Laser Wideth 8ns±2ns.
Whole machine
functions,
Single pulse energy degree showing and adjusting
Pulse wavelenth showing and adjusting
Pulse frenquency and showing adjusting
Working condition and showing adjusting
Safety
inquiry
1, the
electric shock protection: Conforms to GB9706.1-2007 "Medical
electrical equipment Part I: General requirements for safety" in
the Class B Type I device regulations.
2, Laser Radiation Protection: Conforms to GB7247-2001 "Radiation
safety of laser products, equipment classification, requirements
and user\'s guide", the 4 types of medical laser product radiation
safetyrequirements.
Indications
1
Indications,
This instrument is mainly used for eliminate some of the clinical
exogenous and endogenous skin, blue,black, brown pigment lesions,
such as: tattoos, tattoo, nevus of Ota and so on.
2, The treatment interval Two treatment should be about two months
apart, so that the pigment particles were crushed have enough time
to be absorbed.
3, Number of treatment,
Many cases, the treatment generally required to get better results,
the number of specific treatment of patients with the concentration
of pigment from the affected area, depth, pigment composition, each
treatment using the laser dose, patients with macrophages in vivo
absorption of pigment granules and other factors. Generally
exogenous pigment treatment to be more than 3 times, 5 times the
endogenous pigment to be more satisfactory than the treatment
effect obtained a small number of patients with repeated treatment
effect is not satisfactory.
Contraindications
1. For patients with dark skin, we suggest they take treatments
after skin-whitening. Otherwise the skin maybe hurt
slightly.
2. After the treatment, the skin will become red and swollen or
blood infiltrated, if so, patients can ice the treatment skin or
apply some ointment against scar.
3. Some metal ion such as ferric ion will become chemical
substance, if so the skin will be darker after treatment. It is not
the problem of machine self.
4, after the treatment skin should be kept clean and dry to avoid
infection.
5 Postoperative Results boil, should make it off on their own in
order to avoid man-induced scars.
6, Repeating treatment is prohibited in the same area, or tissue
will be damaged due to heat accumulation.
Before and
After:Â
precautions and
instructions,
The actual components of this product have been tuned and locked,
there are components with special requirements need to be sealed at
the factory. Users are not allowed to unsealed, dismantling,
adjustment and changes the parameters have been locked, otherwise
the consequences are due to users..
The radiation shield body, device of remote interlock, key switch, warning device of laser radiation, device of Beam terminated are according to the provision of GB7247-2001. It is set for the safety protection of laser radiation, the users are not allowed to dismantle these devices, so as to affect the protective security.
Laser skin treatment device is the instruments
with light, mechanical, electrical and precision in one. Therefore,
the operators must be trained. Non-trained personnel are not
allowed to operate the machine.
Please read this manual carefully before use, we shall not be held
responsible for the medical accidents and disputes which are caused
by not read or violate compasses operation.
Please must make laser far away from the non-treatment site during
treatment process.
Â
Basic Parameter of
AES-LASER96:
1ã€Physical demension(L×W×H,mm):400×380×800
2ã€Total weight:25kg;
3ã€Consumed power:600Wï¼›
4ã€creepage protectingrated current
5ã€Laser output method:Pulse adjusting Q;
6ã€working Laser wavelength:1064nmï¼›532nm;
7ã€Laser pulse wideth:8ns±2nsï¼›
8ã€Output frequency:1Hzã€2Hzã€3Hz〠4Hzã€
5Hzã€6Hz;
9ã€Single pulse max output energy:100-2000MJï¼›
10ã€Harmed eyes distance:NOHD 1km,operated in dense need wear
eyeshield!
11ã€cooling method:Inlay closed cirlced water.
12ã€Run Mode:Dwell load-on continuious running.
13ã€Flare continuious adjusted.
C Photoelectricity Capability
1ã€Arthrosis bottom Output Max Single Pulse
energy≥500mJ;
2ã€Laser Output enstablity:ST≤±10%;
3ã€Output Power reappear:Rp≤±10%ï¼›
4ã€Output Power and Preset valueshowing
error:≤±20%;
5ã€Operation FlareDiameter:1ï¼4mm continious
adjustingï¼›
6ã€Aimming at Laser outputpower Pc::0.1mW≤Pc≤5mW.
7ã€Laser Wideth 8ns±2ns.
Â