Sell GD-1792 Distillate Fuels Mercaptan Sulfur Tester By Chongqing Yuneng Oil Purifier Manufacture Co., Ltd., China
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs. Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell GD-1792 Distillate Fuels Mercaptan Sulfur Tester

Sell GD-1792 Distillate Fuels Mercaptan Sulfur Tester

2500 ~ 3000 / Set ( Negotiable )

|

Minimum Order

Localit:

China

Prix de commande minimale:

Commande minimale:

1 Set

Packaging Detail:

wooden case

Delivery Time:

15 days

Supplying Ability:

20 Set per Month

Payment Type:

T/T, L/C, Western Union

Contacter maintenant
Membre gratuit

Personne à contacter Mr. zhang

ChongQing, ChongQing, ChongQing

Contacter maintenant

Description

Purpose:
GD****2 Fuels Mercaptan Sulfur Tester is designed and made as per the National Standard GB/T***2 “Test Methods for Mercaptan Sulfur in Distillate Fuels (Potentiometric Titration Methods)”. It is suitable to determine mercaptan sulfur, which is in the range of 0.***3~0.*1% (m/m), in the jet fuels, gasoline, kerosene, and light diesel, which do not contain hydrogen sulfide.
GD****2 Fuels Mercaptan Sulfur Testeris composed of GD******1 PHS*3B pH meter, GD******2 ***1 Magnetic Stirrer and other accessories. It is a standard instrument used for determining mercaptan sulfur in distillate fuels.
 
Technical specification
    (I) PHS*3B pH meter
         1. Instrument grade: Grade 0.*1;
         2. Measurement range:
              (1) pH: (0~*4.*0) pH;
              (2) mV: (0~±***9) mV (automatic polarity display);
              (3) Temperature: (0~**0.0) °C;
          3. Display resolution: 0.*1 pH, 1 mV, 0.1 °C;
          4. Temperature compensation range: (0~*0) °C;
          5. Basic error of the instrument:
              (1) pH: ±0.*2 pH±1 number;
              (2) Temperature: ±0.5°C±1 number;
          6. Temperature compensation error: ±0.*1pH;
          7. Repeatability error for electronic unit:
              (1) pH: not more than 0.*1 pH;
              (2) mV: not more than 1 mV;
          8. Repeatability error for the instrument: not more than 0.*1 pH;
          9. Stability of electronic unit: ±0.*1pH±1 number/3h;
    (II) ***1 Magnetic stirrer:
           1. Working mode: continuous;
           2. Maximum stirring capacity: ***0 ml;
           3. Heating power: **0 W, continuously adjusted;
           4. Temperature controlling accuracy: ±0.1°C;
           5. Temperature controlling range: 5 °C over room temperature~**0°C;
           6. Timing range: *0 to ***0 min;
           7. Reversal time: 5~*0 s;
     (III) Titration tube: *0 ml, each scale division is 0.*5 ml;
 

Send a direct inquiry to this supplier

To:

Mr. zhang < Chongqing Yuneng Oil Purifier Manufacture Co., Ltd. >

Je veux savoir: