FOB Price
Obtenir le dernier prix( Negotiable )
|Minimum Order
Localité:
China
Prix de commande minimale:
-
Commande minimale:
1 Set
Packaging Detail:
Carton
Delivery Time:
Within 4 weeks after receiving your payment
Supplying Ability:
100 Set per Month
Payment Type:
T/T, L/C, Western Union
OVERVIEW:
AS****0 comprises sampling subsystem, gas measuring subsystem, smoke measuring subsystem, auxiliary parameter measuring subsystem, data collecting and handling subsystem, blowback subsystem and other monitoring subsystem, which can continuous monitoring SO2, NOX, *2,SO2,NOX,O2,CO,CO2,NH3,HF, HCL,PM*0, flow rate of exhaust gas, temperature, pressure, humidity and other gas parameters, the ratio and volume doses of emission will be calculated, printed, displayed, managed, and transferred to relevant department by data and textual pattern transmission system.
AS****0Continuous Emission Monitoring System is mainly used stack gas monitoring of boiler, kiln, refuse burning and etc. Crucial parts of this system are the advanced diode array fiber-optics spectrophotometers and laser dust density monitor, processing all intellectual property rights of the core instrumentation.
Â
FEATURES:
Automatic analyzing the concentration of one or more components of the concentration of SO2,NO,CO,CO2,O2,C2H4 and gaseous pollutant in the mix gas, but also detecting the discharge flue dust in the fume and the monitoring of process parameters;
Measuring results will be stored in the data sampling control system automatically;
All kinds of ways of transmission can be compatible, multi-levels networking;
Standard modular design, easy to maintain, upgrade and expand;
CEMS system can be self-diagnosed, including invalid probe and detecting source, range exceed alarm, breakdown of main units alarm, timely fault notice during the operation;
Site data timely transferred, fault remote diagnosis;
Auto-calibration zero by air(
Data can be collected, stored, handled and distinguished by data system, which can control the daily construction of CEMS, including cycling auto-correction, auto-reverse blowing probe and filter of sampling system, providing the information what approved test and monitoring needed;
Multichannel 4~*0MA analog output and relay contact output;
high-accuracy, stable
short preheating time*5mins
bilingual menu operation
User can do the man-machine interaction through keyboard and LCD in the front
system can non-stop operate at least *0 days with no need for daily maintenance
Interval time: one adjusting every **6 months according to environmental condition
easy to use, operate and set, low-cost, low work load for maintain
Â
SPECIFICATION:
ITEM |
SPECIFICATION |
Measuring elements |
SO2,NOx or O2 (according to user’s requirements, no O2 sometimes) |
Measuring range |
SO2 0 ~ ***0mg/m3 NOx 0 ~ ***0 mg/m3 O2 0 ~ *5vol% |
Repeatability |
Each gas component, respective range±0.5%(FS) |
Digital display drift |
Each gas component, respective range within ±1% |
Zero drift |
Each gas component, respective range within ±2%/weeks |
Drift |
Each gas component, respective range within ±2%/weeks |
Linearity |
Each gas component, respective range within ±2%/ |
Response time |
Each gas component, its respective measuring range within **0 seconds, but SO2 within **0 seconds |
Stability relative to ambient temperature |
The temps changes within ±5°C, satisfied the specified value of zero drift and span drift |
Quantity of sample |
About 3L/min |
Method of correction |
manual automatic:(0~**9 hour) |
Gas revise |
Zero gas **0%N2 standard gas Span gas SO2 in N2 standard gas NO in N2 standard gas O2 in N2 standard gas or air) |
Enable condition |
Temp.:*5 ~ *0°C.Humidity:*5%RH below, no radiation Direct sunlight, the place with more vibratory |
External input and output |
Applied in the circumstance of power-off, maintenance, analyzer alarm, correction and others |
Voltage |
AC**0V±*2V,*0/*0Hz(optional)about *0A |
size |
overall dimension drawing for reference |
weight |
About **0Kg |
Material of connected parts |
Polyethylene, glasses, Teflon, Viton |
Await sample gas pressure |
*1Kpa ~ *1Kpa |
Standard sample gas |
Temp.:**0°C below Dust:0.1g/Nm3 SO2:***0mg/m3 below NOx:***0 mg/m3 below H2O:0.8 ~ *0wt% |
Storage |
Surrounding Temp.:**0 ~ *0°C Humidity:*0% below Others: cannot be stored in the air of corrosive ( shall open the package, on the breezy place |
Â
APPLICATION FIELD:
Monitoring the waste gas emission from Power Generation, Thermal Power, Iron and Steel, Petrochemical, Cement, Waste Power, Desulphurization and Denitrification, Tobacco, Paper and so on.