FOB Price
Obtenir le dernier prix( Negotiable )
|Minimum Order
Localité:
Guangdong
Prix de commande minimale:
-
Commande minimale:
2 Set
Packaging Detail:
plastic bag+shaped white foam+export paper carton
Delivery Time:
within 5 days for small order
Supplying Ability:
5000 Set per Month
Payment Type:
T/T, L/C, Western Union, PayPal
Personne àcontacter Ms. Lucy
No2 Nanhe, shunde Foshan, Guangdong
1) The boilers are to have 2 functions – Heating & Hot water supply which work autonomously from one boiler. One mode is to heat the apartments. The other is to supply with hot water for apartments.
Both circulation rings are to be separated and to work in different temperature range.
2)Two heating models to select, they can change each other easily through "Model changer" on the bottom.
Floor heating: *0~*5°C;
Radiator: *0~*0°C,
it is free to set up the temperature.
3)Domestic hot water is prior. When hot water faucet is opened the gas boiler convert from Heating mode to Domestic hot water mode and modulating gas valve allows to heat water evenly. Gas boiler continue to heating water until the source is closed and then The boiler return to Heating mode or standby smoothly.
Above conversion be controlled automatically by
Microcomputer inside boiler.
4) Anti-freeze protection measure. When the room temperature drop to below 7°C the circulating water pump operate and modulating gas valve allows to warm the water to *0°C then boiler stop working.
Above operation also be controlled automatically by Microcomputer inside boiler.
5)Pressure
release valve.
When the Heating system pressure reach to 3 bar the safety valve
will be opened to relief the high pressure automatically.
6)Balanced
flue,means Admission pipe inside the
Exhaust pip like the concentric circles.
Its advantage is not only discharge
the exhaust gas outside but also consume the outdoor fresh air
instead of indoor. Moreover the high temp exhaust gas can preheat
cold outside air that can increase the boiler heat
efficiency.
7)Technical Parameter
Thermal efficiency: *0% Applying space:
*0~**0sqm Energy: LPG/ Nature gas/ Man made gas
Rated Gas Pressure: LPG****0Pa / Nature gas****0pa
Exhaust style: Compulsive Supply & Exhaust system
Cold water inlet pressure: 0.5~3.0Pa
Hot water outlet pressure: 0.2~5.0Pa
Expansion tank capacity: 7L/8L
The highest temperature: *0℃-Heating
*5℃-Shower
Rated Volt: **0V
Frequence: *0Hz/*0Hz Rated Electric power:
≤**0W for
Heating *0W
for Shower Specification of Smoke tube :
Length- **0cm
Diameter- *0mm for exhaust
pipe
**0mm
for air inlet pipe Specification of joints: G3/4" for
gas inlet ; G1/2" for cold water
inlet
G3/4" for hot water outlet & circulating
water