FOB Price
Obtenir le dernier prix|
Minimum Order
Localité:
Jinan ,China
Prix de commande minimale:
-
Commande minimale:
5 Piece
Packaging Detail:
Carton box with sponge
Delivery Time:
3-4days
Supplying Ability:
-
Payment Type:
T/T, Western Union, PayPal
Personne àcontacter Ms. Della
15Lanxiang road, Jinan, Shandong
Main Features
1) High output voltage and current when inputting AC**0V and outputting current up to *8mA, the voltage can be up to *5KV.
2) Response time1Ms(from the time that switch Signal is given to the output current up to *0 percent of the setting current)
3) Increase the power of laserUsed with ***0mm laser, the peak of laser power can be up to **0W and the average power is **0W.
4) Dramatically lengthen the life of laser.
5) Easy ControlThe start and stop of laser can be easily controlled by TTL level. And there are protection switch to test the external water, ventilation, etc.
6) Easy control of laser power Both **5V analog signal and PWM signal can control the laser power.
7) The power supply possesses open circuit protectionUnder the condition of good protective earthing, the power supply can work in open-circuit for a short time, which could avoid the damage of laser power supply because of the bursting of laser tube, thereby enhancing the life of power supply.
8) The power supply can take feedback interface which can be used in closed-loop control and testing the working current of laser.
9) The power supply adds a new function, that is timely scene judging which part is damaged, laser tube or laser power.
*0) Applicationthick acrylic cut, fabric cut, etc.
2. Specification
Input |
Input Voltage |
AC**0V or AC**0V(to be specified when placing order) |
|
AC frequency |
*7—**0HZ |
||
Cold Surge Current |
*0A(AC**0V Input) |
*0A(AC**0 Input) |
|
Current Leakage |
0.7mA(AC**0V Input) |
0.4mA(AC**0V Input) |
|
Output |
Maximum Input Voltage |
DC *0KV |
|
Maximum Output Current |
DC *8mA |
||
Efficiency |
*0 percent (full load) |
||
Mean Time Between Failure (MTBF) |
****0H |
||
Response Speed |
1ms(from the switch Signal is given to the output current up to *0 percent of the setting current) |
||
Control Interface |
TTL level switch control; high or low effective level can be chosen (details refer to the control terminal specification) |
||
Withstand Voltage |
Input-Output, Input-Shell AC***0V *0mA *0S; Output negative is connected with machine shell. |
||
Protection |
can work in open-circuit condition for a short time(Require a good protective earthing and avoid arc between the positive and the machine shell) |
||
Environment |
Operating Temperature**0~*0°C,Relative Humidity (RH)*0 percent |
||
Cooling Way |
Force-Air Cooling (FAC) |
||
Dimension |
L×W×H=**5***0**5(mm) |