Sell portabel ph meter PH8414 By Hangzhou ROCK Biotechnology Co., Ltd, China
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs.
Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell portabel ph meter PH8414

Sell portabel ph meter PH8414

( Negotiable )

|

Minimum Order

Localit:

hangzhou

Prix de commande minimale:

-

Commande minimale:

10 Piece

Packaging Detail:

neural packing

Delivery Time:

within 3-5 working days

Supplying Ability:

3000 Piece per Week

Payment Type:

T/T, L/C, Western Union, Money Gram, PayPal

Contacter maintenant
Membre gratuit

Personne à contacter Ms. ally

qiutao, Hangzhou, Zhejiang

Contacter maintenant

Description

Portable & Digital PH Meter PH****4

 

Specifications

Product name: Portable & Digital PH Meter

Model: PH****4

 

Technical data:

Measuring range: pH: 0.*0~*4.*0

mV: ****9~***9mV

°C: 0~**0°C

Resolution: pH: 0.*1pH

mV: 1mV

°C: 1°C

Accuracy: pH: ±0.*1pH

mV: ±1%

°C: ±0.4°C

Input impedance:**2 Ω

Calibration: 1 or 2point

Working condition: 0 to *0°C, RH<*5%

(Without magnetic interference around the

meter & conspicuous centrum)

Power: 9V battery

Auto shut-off:: Approx. 8minutes

Operating conditions: 0~*0°C RH≤*5%

Dimension: **6×*6×*6mm

Weight: **0g

Feature: High precision,complete-function,detection result display synchronously, operation simply.

 

MODEL

PH****4

 

Measuring range

pH: 0.*0~*4.*0

mV: ****9~***9mV

°C: 0~**0°C

Resolution

pH: 0.*1pH

mV: 1mV

°C: 1°C

Accuracy

pH: ±0.*1pH

mV: ±1%

°C: ±0.4°C

Input impedance

**2 Ω

Calibration

1 or 2point

Power

9V battery

Working temperature

0~*0°C, RH≤*5%(Without magnetic interference around the meter & conspicuous centrum)

Auto shut-off

Approx. 8 minutes

Dimension

**6×*6×*6mm

Weight

**0g

 

PH****4 PORTABLE PH/mV/℃ Meter

 

OPERATION MANUAL

1. General Description

The PH****4 PH meter has been specially designed for the maximum facility of use. The handy key board for the selection of the various functions.

The possibility of automatically correcting errors in measurement due to temperature .The display on the front panel reveals the temperature and PH or mV reading taken by the instrument. Moreover, PH****4 features a low battery

indicator 。

2.Specifications

Range: PH 0.*0~*4.*0PH

mV ﹣***9~***9mV

Temperature 0~**0℃

Resolution: PH 0.*1PH

mV 1mV

Temperature 1℃

Accuracy: PH ±0.*1PH

mV ±0.1% of the reading ±1 digit

Temperature ±0.4℃

Input Resistance: *0 *2

Calibration: 1point or 2point

Power: 9V battery

Dimensions: **6×*6×*6mm

Operating Conditions : Temperature 5~*0℃ Humidity *5%

Maximum

 

No disturbance of magnetic field or distinct tremble around

instrument.

Weight:**0g

3.The front panel

Here is a brief description of the functions performed by each of the keys present on the keyboard.

ON/OFF: this is used for switching the instrument On and Off.

PH: this indicates the PH measurement revealed by the electrode.

mV: this indicates on the display panel the mV value revealed by the electrode.

℃:this indicates the temperature value revealed by the probe. This is the v *1c4 alue used by the circuit for the PH measurement compensation.

LIGHT: lightens LCD the back light.

On the lower part of the front panel, tow trimmers are found for the regulation of the instrument. Their use will be described in chapter.

4.Interface and battery installation

This instrument has 2 functional interfaces and each of them is only to fit with its own plug.

1. PH electrode interface (or ORP) 2. temperature sensor interface Battery replace: the “**-” symbol on the left of the LCD to indicate a low battery condition .Battery must be replace. Open the cap of battery on the back of the instrument and replace of the old battery with new battery. Attention to the anode and cathode of battery.

5.Operation

PH MEASUREMENTS: ·Turns on the PH electrode and the temperature sensor .

Turn the meter ON by pressing the ON/OFF key.

·Remove the PH electrode protective cap, then submerge the PH electrode and the temperature probe into the sample to be tested.

·Stir gently and wait for the stability symbol. The display will show the PH value automatically compensated for temperature.

·After use, rinse the electrode with clean water, replace the electrode protective cap.

ORP MEASUREMENTS: Oxidation Reduction Potential(ORP) measurements provide a quantification of the oxidizing or reducing power of the sample tested.

·Connect the ORP electrode to the BNC connector.

·To enter the〝mV〞mode turn the instrument ON and press the mV key until the display changes to mV.

·Then submerge the ORP electrode into the sample to be tested and allow time for the reading to stabilize.

TEMPERATURE MEASUREMENTS:

·Make sure the temperature probe is connected to the meter.

·Turn the instrument ON and press the ℃ key to select the temperature mode.

·Dip the temperature probe into the sample, allow the reading to stabilize and read the temperature value.

6.PH Calibration

·Pour a small quantity of PH6.*6 and 4.*1(or PH9.*8)solution into clean beakers.

·For a particularly accurate calibration, it is advised to use two beakers for each buffer solution .the first is to be used for rinsing the electrode, the second is to be used for the calibration, in this way, the risks of contaminating the buffer solution are reduced to a minimum.

·Switch on the instrument. Press the PH key to display the PH measurement.

· Immerse the PH electrode and temperature probe into PH 6.*6 buffer solution and then shake briefly.

·Regulate the trimmer found in the lower left hand position with a screwdriver until the buffer solution value corresponding to the measurement temperature is obtained.

·Immerse the electrode into a PH4.*1 or PH9.*8 buffer solution, and briefly shake the electrode.

·After about one minute, regulate the trimmer found in the lower right hand position until the buffer solution value corresponding to the measurement temperature is

obtained.

·The calibration of the instrument′s PH range is now complete.

Important:

The instrument′s PH range must be recalibrated whenever.

·The electrode has been replaced.

·Approximately one mouth has passed from the last calibration.

·The electrode has been used in particularly taxing conditions.

·The utmost accuracy is required.

7.Maintain electrode and instrument

1.Keep the electrode pin dry and clean.

2.Wash the electrode every time before you use. Then put it in 3mol/L KCL solution.

3.The electrode which is use to measure solution should not be dipped in distilled water , protein solution or other solution for long time.

8.Buffer Table

℃ PH4。*0 PH6。*6 PH9。*8 ℃ PH4。*0 PH6。*6 PH9。*8

0 4.*1 6.*8 9.*6 *5 4.*4 6.*3 9.*4

5 4.*0 6.*5 9.*9 *0 4.*6 6.*3 9.*2

*0 4.*0 6.*2 9.*3 *5 4.*7 6.*3 8.*9

*5 4.*0 6.*0 9.*8 *0 4.*9 6.*4 8.*7

*0 4.*0 6.*8 9.*3 *5 4.*1 6.*4 8.*5

*5 4.*0 6.*6 9.*8 *0 4.*2 6.*5 8.*3

*0 4.*1 6.*5 9.*4 *0 4.*6 6.*6 8.*9

*5 4.*2 6.*4 9.*0 *0 4.*0 6.*8 8.*6

*0 4.*3 6.*4 9.*7 *5 4.*2 6.*9 8.*4

9.Warranty

This instrument is guaranteed from all defects in material and production for a period of one year from the date of purchase. If during these periods the repair or the replacement of the instrument is required and the damage is not due to negligence or erroneous operation by the user, please return

the instrument to either your dealer or to our offices and the repair will be effected free of charge.

 

 

 

 


Send a direct inquiry to this supplier

To:

Ms. ally < Hangzhou ROCK Biotechnology Co., Ltd >

Je veux savoir: