FOB Price
Obtenir le dernier prix|
Minimum Order
Localité:
china
Prix de commande minimale:
-
Commande minimale:
1 Piece
Packaging Detail:
-
Delivery Time:
25days
Supplying Ability:
-
Payment Type:
L/C, T/T
Personne àcontacter amanda
west Minzhou Road, Ningbo, Zhejiang
Features
1. The gas chromatograph offers high
accuracy of temperature control (optimum: ± 0.*5°C), high
reliability and anti-interference.
2. Control and operating parameters, including for detectors, can
be set up by the keyboard. Settings include elf-diagnosis system,
power-fail protection, file storage and load, and limited
temperature. The gas chromatograph uses accurate display of setting
and actual value of temperature control of each path, bridge
current of TCD, sensitivity of FID, retention and analysis
time.
3. It offers four paths of independent control sections, including
column oven, sample injector, detector and thermal conductive
pond.
4. It has *-ramp programmed temperature rising control and
auto-drop of temperature of column oven to a fast cooling.
5. Dual FID provided with options of GC**2 A-TCD, GC **2 A-FPD and
GC**2A-NPD, gas sampling valve, transformation oven, absorber and
pyrolysis absorber are available for selection. Two detectors can
be installed at the same time with high sensitivity. It takes a
short time to be stabilized, it is easy to clean and install
nozzle.
6. A packed column and capillary column (0.*3 large diameter or
small diameter) can be easily installed including a complete set of
split sampling connector and tailing connector to be installed free
of charge. An optional 0.*3mm large diameter capillary direct
sampler is available for choice.
7. Analysis can be conducted in packed or capillary column with
multiple sampling methods.
8. A packed column can finish on-column sampling, instantaneous
vaporized sampling and gas sampling.
9. The gas chromatograph uses capillary column, which can support
split sampling and 0.*3mm large diameter capillary direct
sampling.
*0. Construction of dual gas path, dual sample injector and dual
packed column system can effectively avoid baseline undulation and
drift in real time and facilitate programmed temperature rising
analysis. Accurate and scaled type gas path control valves will
provide repeatability and stability of the gas chromatograph.
*1. The gas chromatograph supports an auto ON/OFF temperature
control system, permanent data storage, file storage and call and
over-temperature protection.
*2. The large capacity column oven (**0x**0x**0mm) can hold
capillary column and dual packed column. Built-in heating filament
structure is in favor of quartz capillary analysis.
*3. A complete set of accessories including purifier,
pressure-reducing valve, gas path tube, wrench and tools, injection
needle and connectors of all kinds are provided free of charge and
are ready to connect with the supply-air system prepared by
users.