electric energy meter By jiansu acxion electrical co ., ltd, China
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs.
Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
electric energy meter

electric energy meter

60 / Piece

|

Minimum Order

Localité:

-

Prix de commande minimale:

Commande minimale:

5 Piece

Packaging Detail:

packed as customers' requirement

Delivery Time:

within two weeks

Supplying Ability:

10000 Piece per Month

Payment Type:

T/T, L/C, Western Union, Money Gram, PayPal

Contacter maintenant
Membre gratuit

Personne à contacter Joanna

cheng rode, Beijing, Beijing

Contacter maintenant

Description


 

Parameters

Accuracy

Electric quantity 0.5; Active energy 0.5, Reactive energy:1

Display mode

Blue backlight LCD Display

Signal

Input

Wiring

three phase four wires, three phase three wires

Voltage

Rated Value

AC**0V,AC**0V

Overload

Continuous: 1.2 times, instantaneous: 2 times during *0 seconds

Consumption

<1VA(each phase)

Impedance

>**0k&branded;

Current

Rated Value

AC1A, AC5A

Overload

Continuous: 1.2 times, instantaneous: *0 times during 5 seconds

Consumption

<0.4VA(each phase)

Impedance

<*0m&branded;

Frequency

****5Hz, accuracy: ±0.*1Hz

Energy

Bi-directional active energy, reactive energy metering

Power

Supply

Work Range

AC/DC: *0V - **0V

Power Consumption

<5VA

Function

Module

Energy Pulse Output

2 loops energy pulse output, opto-coupler, constant : ***0imp/kWh(kvarh)

Communication interface

1 RS***5, Modbus-RTU, speed: ***0~****0

Digital input

Up to 4 digital inputs

Transmission Output

1 analog output: 0/***0mA or **5/*0V

Time Clock Error

<0.5s/d

Operation Environment

*****5°C, humidity≤*3%, no erosion place, altitude≤***0m

Storage Environment

*****5°C, humidity≤*3%

Safety

Insulation

Signal, power, output terminal to shell resistance>**0M&branded;

Withstand Voltage

 

Input & power>2kV, input and output >1kV, power and output>2kV

 

Parameters

Accuracy

Electric quantity 0.5; Active energy 0.5, Reactive energy:1

Display mode

Blue backlight LCD Display

Signal

Input

Wiring

three phase four wires, three phase three wires

Voltage

Rated Value

AC**0V,AC**0V

Overload

Continuous: 1.2 times, instantaneous: 2 times during *0 seconds

Consumption

<1VA(each phase)

Impedance

>**0k&branded;

Current

Rated Value

AC1A, AC5A

Overload

Continuous: 1.2 times, instantaneous: *0 times during 5 seconds

Consumption

<0.4VA(each phase)

Impedance

<*0m&branded;

Frequency

****5Hz, accuracy: ±0.*1Hz

Energy

Bi-directional active energy, reactive energy metering

Power

Supply

Work Range

AC/DC: *0V - **0V

Power Consumption

<5VA

Function

Module

Energy Pulse Output

2 loops energy pulse output, opto-coupler, constant : ***0imp/kWh(kvarh)

Communication interface

1 RS***5, Modbus-RTU, speed: ***0~****0

Digital input

Up to 4 digital inputs

Transmission Output

1 analog output: 0/***0mA or **5/*0V

Time Clock Error

<0.5s/d

Operation Environment

*****5°C, humidity≤*3%, no erosion place, altitude≤***0m

Storage Environment

*****5°C, humidity≤*3%

Safety

Insulation

Signal, power, output terminal to shell resistance>**0M&branded;

Withstand Voltage

 

Input & power>2kV, input and output >1kV, power and output>2kV

 

Parameters

Accuracy

Electric quantity 0.5; Active energy 0.5, Reactive energy:1

Display mode

Blue backlight LCD Display

Signal

Input

Wiring

three phase four wires, three phase three wires

Voltage

Rated Value

AC**0V,AC**0V

Overload

Continuous: 1.2 times, instantaneous: 2 times during *0 seconds

Consumption

<1VA(each phase)

Impedance

>**0k&branded;

Current

Rated Value

AC1A, AC5A

Overload

Continuous: 1.2 times, instantaneous: *0 times during 5 seconds

Consumption

<0.4VA(each phase)

Impedance

<*0m&branded;

Frequency

****5Hz, accuracy: ±0.*1Hz

Energy

Bi-directional active energy, reactive energy metering

Power

Supply

Work Range

AC/DC: *0V - **0V

Power Consumption

<5VA

Function

Module

Energy Pulse Output

2 loops energy pulse output, opto-coupler, constant : ***0imp/kWh(kvarh)

Communication interface

1 RS***5, Modbus-RTU, speed: ***0~****0

Digital input

Up to 4 digital inputs

Transmission Output

1 analog output: 0/***0mA or **5/*0V

Time Clock Error

<0.5s/d

Operation Environment

*****5°C, humidity≤*3%, no erosion place, altitude≤***0m

Storage Environment

*****5°C, humidity≤*3%

Safety

Insulation

Signal, power, output terminal to shell resistance>**0M&branded;

Withstand Voltage

 

Input & power>2kV, input and output >1kV, power and output>2kV

Digital display multifunction power meter
High-light LED display
High Accuracy
CE Certification
RS***5 interface

 

     Digital Display Multifunction Power Meters have extremely good performance;

    they can directly replace conventional power transducers, measurement indicators, electric energy metering instruments and relevant auxiliary units.

   As a kind of advanced intelligent digital front-end collection elements of power network, they are widely used in different kinds of control systems, SCADA system and energy management system as well as in automatic substation system, automatic distribution network system, power monitoring for residential quarter, industrial automation, intelligent buildings, intelligent switchboard and switch cabinet.

   They have the advantages of convenient installation, simple wiring, easy maintenance, less workload. They can be programmed and input parameters directly and complete the networking of communication software for different PLC and industrial control computers.

Send a direct inquiry to this supplier

To:

Joanna < jiansu acxion electrical co ., ltd >

Je veux savoir: