LU-L adopts proliferate silicon pressure
sensors groupware which produced by famous NovaSensor, American
company and with high accuracy & high stability. Through high
stability amplifier electric circuit and accurate temperature
compensation, it can transfer the measured liquid signal to
4~*0mADC standard electric signal.
Exquisite seal technology and perfect installation process
can insure the high quality & best performance. LU-L have two
structure types: one-body type and separated-body type, and
according to measured mediums, there are electric cable type,
armored type and anti-corrosive type. Armored type and
anti-corrosive type can resist corrasion of several kinds of
corrosive liquid, can widely suit for user’s
requirement.
LU-L have two types: common type and intrinsically-safety
& explosion-proof type. Explosion-proof type can be used to
each kind of execrable or hazardous industrial field.
2.characteristic:
·0~0.3m to 0~**0m,
·one-body type and separated-body
type,
·electric cable type, armored type
and anti-corrosive type,
·prevent lightning strike and radio
disturbance,
·reverse polarity protection and
current-limit protection,
·Intrinsically-safety &
Explosion-proof,
·zero & span external
continually adjusted,
·High accuracy, high stability and
high reliability.
3. applicant:
·liquid survey and control of
industry field,
·hydrology survey and
control,
·Navigation and shipping
manufacture,
·City water supply & sewage
dealing with,
·Great river & dam and
irrigation water construction,
·Gas separate device and thermal
motors,
·Food and soft drink
device,
·Chemical and hospital
device,
4.technical index
·Measured medium:
Water and common non-corrosive liquid (electric cable
type);
Each kind of liquid which compatible to **6L ( armored
type);
Each kind of corrosive liquid (anti-corrosive type);
·range ability: 0~0.3m to
0~**0m,
·over-load pressure: 2 times of
max. range,
·output: ***0mA DC
(*-wires)
·working voltage: *4~*6VDC
(*-wires), standard *4VDC±5%, Wpp<1%,
·medium temperature: **5 ~
***0℃,
·environment temperature: **0 ~
**5℃
·Load resistance:
(4~*0mA): R =(U**4)/0.**-R0,[U is power voltage, R0is electric cable inner resistance],
(0~*0mA): R≤1K&branded;,(0~5V):
R≥**0&branded;
5. performance index
·Accuracy:±0.*5%, including the synthesize
errors of non-linear, repeat and return difference.
·Zero error:≤±0.5% of output range (only
for one-body type),
( zero error is adjusted for separated-body
type);
·zero shift: 0~**0% of the max.
range (only for separated-body type),
(no zero shift for one-body type)
·range adjustment: can
willfully adjust between the min. and max. ranges (only
for separated-body type),
(range could not be adjusted for one-body type)
·Over-pressure
affect:<0.*5%
of max. range
·Power affect: <0.*1% of output
range
·Load affect: can be
neglected
·Temperature
affect:±1.5% of
max. range (temperature –*0~*5℃, including zero
& span affections)
·Stability:±0.*5% of max. range (*2
months)
6. structure index:
·Diaphragm material: **6L stainless
steel (for electric cable type and armored type);
Ceramic (for anti-corrosive type)
·detection head material:
1Cr*8Ni9Ti (for electric cable type and armored type);
PTFE. (for anti-corrosive type)
·lead-out line:
ventilate cable which outer diameterΦ9, double layer, wearable and
water-proof (electric cable type);
armored pipe which outer diameterΦ6, stainless steel (armored
type);
PTFE. Soft pipe which outer
diameterΦ7.5
(anti-corrosive type);
·line connection box: aluminum
alloy with plastic-spouted around the surface,
·indicate meter: 0~**0% linear
indication (analog meter, only separated-body type);
**1/2 LCD digit display (digit display meter, only separated-body
type);
·explosion-proof:
Instrinsically-safety: Ex iaâ…¡ CT5;