PM60D (ECG, Spo2, NIBP, PR) By Contec Medical System Co., Ltd, China
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs. Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
PM60D (ECG, Spo2, NIBP, PR)

PM60D (ECG, Spo2, NIBP, PR)

500 / Piece

|

Minimum Order

Localité:

contec

Prix de commande minimale:

Commande minimale:

-

Packaging Detail:

carton

Delivery Time:

1

Supplying Ability:

1000 Piece per Day

Payment Type:

T/T, Western Union, PayPal

Contacter maintenant
Membre gratuit

Personne à contacter ashley

Zhangjiakou, Hebei

Contacter maintenant

Description


Feature:

â–  Routine Check Mode and Continuous Monitoring Mode

â–  Data Graph and Trend Table Review

â–  Rich Analysis Report

â–  Perfect Mount Solution

â–  Convenient operation by touch screen

â–  Large SD card memory for more than ***0 patient cases storage

â–  Sync with PC based Sofrware (WinXP and WinVista)

Performance Specifications:

â–  Display:3.5" Color TFT

â–  Resolution:**0x**0

â–  Display Mode:Standard face, Waveform face, SPO2 view, ECG view, BigNum view                 

â–  Indicator:Power indicator light, Alarm sound, Pluse tone

â–  Interface:One dual-purpose socket for connecting sensors  and communication cables

â–  Power Supply:DC 5V, <**0MA

â–  Battery:Builtin Li-Polymer, 2 hours for charging, 3 hours

â–  for continous working.*0 hours for standby mode

â–  Trend Graph:Resolution from 1s, 5s, *0s. Maximum time *6 hours.

â–  Trend Table:Resolution from 1s, 5s, *0s. Review up to ***0 items.

â–  Alarm:Ajustable High and Low limits. Three level audible and vistual alarm

â–  User Configuration:All the color of parameters and waves can be set according to user's willing

Technical specifications:

â–  Safety

â–  Meet the requirment of IEC****1 series

â–  Type of Protection:Class II with internal electirc power supply

â–  Degree of Protection:BF

â–  Dimention and Weight

â–  Dimention:*2(W)x*2(H)x*2(D)mm

â–  Weight:**6g(with battery)

â–  Operation Environment:

â–  Temperature:0℃~ **0℃

â–  Humidity:*5% ~ *5%

â–  Storage Environment:

â–  Temperature:**0℃~ **0℃

â–  Humidity:*0% ~ *5%        

â–  Patient Range

â–  Neonate ,Pediatric and  Adult

SPO2:

â–  Measurement Range:0 ~ **0%

â–  Resolution:1%

â–  Accuracy:±2%(*0%~**0%, Adult/Pediatric, non-motion)

                   ±3%(*0%~**0%, Neonate, non-motion)

                    0% ~ *9% unspecified

â–  Alarm Range:0% ~ **0%

â–  Refreshing Rate:1s

Pulse Rate:

â–  Measurement Range:*5 ~ **0 bpm

â–  Resolution:1bpm

â–  Accuracy:±bpm (non-motion)

â–  Alarm Range:*5 ~ **0 bmp

â–  Refreshing Rate:1s

ECG:

â–  Lead mode:*-lead or *-lead

â–  Lead selection: I, II, III, AVR, AVL, AVF, V

â–  HR range:*5 ~ **0 bpm

â–  ECG Waveform:2 channals

â–  Accuracy:±2bpm or ±2%, which is greater

â–  S-T segment detection, range: *2.0mv ~ *2.0mv

â–  Arrhythmia analysis: *3 kinds of arrhythmia

â–  Alarm Range:*5 ~ **0 bpm

NIBP:

â–  Method:Oscillometry

â–  Mode:Manual/Auto/Contiuous

â–  Measurement Range:*5 ~ **0mmHg

â–  Atuo Measure Interval: 5, *0, *5, *0, *5, *0, *0 minutes

â–  Resolution:1mmHg

â–  Overpressure Protection: **0mmHg

â–  Alarm range:*5 ~**0mmHg

Send a direct inquiry to this supplier

To:

ashley < Contec Medical System Co., Ltd >

Je veux savoir: