FOB Price
Obtenir le dernier prix80 / Piece
|Minimum Order
Localit:
contec
Prix de commande minimale:
Commande minimale:
-
Packaging Detail:
carton
Delivery Time:
1
Supplying Ability:
1000 Piece per Day
Payment Type:
T/T, Western Union, PayPal
Personne à contacter ashley
Zhangjiakou, Hebei
Major Features
â– Integrated with SpO2 probe and
processing display module
â– Small in volumeã€light in weight and convenient in
carrying
â– Operation of the product is simple ,low power
consumption
â– Operation menu for the function setting
â– SpO2 value display
â– Pulse rate value display, bar graph display
â– Pulse waveform display
â– The display mode can be changed
â– A pulse rate sound indication
â– With measured data overruns limits and low-voltage alarm
function, the upper/down alarm range is adjustable
â– Low-voltage indication: low-voltage indicator appears
before working abnormally which is due to low-voltage, and with
alarm function
â– With SpO2 value and pulse rate value of storage, the
storage data can be uploaded to computers
â– Real-time data can be transmitted to computers
â– Automatically power off function: when the device is under
the state of measuring interface . it will automatically power off
within 5 seconds if the finger falls out of probe
â– RF Wireless communication function(Option)
â– Connected with an external oximeter
probe(Option)
Main performance
Display Mode: 0.*6" Dual color OLED
display
Screen Resolution: **8**4
SpO2 Measuring Range: 0%~**0%, (the resolution is 1%).
Accuracy: *0%~**0%: ±2% ,Below *0% unspecified.
PR Measuring Range: *0bpm~**0bpm, (the resolution is 1bpm)
Accuracy: ±2bpm or ±2% (select larger)
Measurement Performance in Weak Filling Condition:
SpO2 and pulse rate can be shown correctly when pulse-filling ratio
is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2%
(select larger).
Resistance to Surrounding Light: The deviation between the value
measured in the condition of man-made light or indoor natural light
and that of darkroom is less than ±1%.
Power Consumption: less than *0mA
Voltage: DC 3.0V
Power Supply: 1.5V (AAA size) alkaline batteries ×
2
Battery Working Hour: The minimum continually work time is *4 hours
, theoretical number is *2 hours.
Safety Type: Interior Battery, BF Type
Accessories
Sell in standard:
â– A hanging rope
â– A user manual
â– A data line
â– A disk (PC software)
Sell in addition:
â– RF wireless module
â– Oximeter probe(Refer to probe application instruction for
details and notice renewal)
Physical Identity
Dimension: *8.5(L) × *1(W) × *2 (H) mm
Weight: About *2g (with the batteries)
Qualification
Passed CE