Principle of the CMS*0G1/G2 Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology, the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc.
Major
Features
â– Integrated with SpO2 probe
and processing display module
â– Small in volumeã€light in weight and convenient in
carrying
â– Operation of the product is simple , low power
consumption
â– SpO2 value display
â– Pulse rate value display, bar graph display
â– Pulse waveform display
â– PI display
â– The display mode can be changed
â– Screen brightness can be changed
â– A pulse rate sound indication
â– With measured data overruns limits and low-voltage alarm
function
â– Low-voltage indication: low-voltage indicator appears
before working abnormally which is due to low-voltage, with alarm
function
â– Automatically power off function: when the device is under
the state of measuring interface . it will automatically power off
within 5 seconds if the finger falls out of probe
â– Display format can be saved after power
off
Main performance
Display Mode: 0.*6"Dual-color OLED display
Screen Resolution: **8**4
SpO2 Measuring Range: 0%~**0%, (the resolution is 1%).
Accuracy: *0%~**0%: ±2% , Below *0% unspecified.
PR Measuring Range: *0bpm~**0bpm, (the resolution is
1bpm)
Accuracy: ±2bpm or ±2%, (select larger)
PI Measuring Range: 0%~*0%, (the resolution is 0.1%)
Measurement Performance in Weak Filling Condition:
SpO2 and pulse rate can be shown correctly when pulse-filling ratio
is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2%
(select larger).
Resistance to surrounding light: The deviation between the value
measured in the condition of man-made light or indoor natural light
and that of darkroom is less than ±1%.
Power Consumption: less than *0mA
Voltage: DC 3.0V
Power Supply: 1.5V (AAA size) alkaline batteries × 2
Battery working hour: Theoretical number is *4 hours.
Safety Type: Interior Battery, BF Type
Accessories
Sell in standard:
â– A hanging rope
â– A user manual
Physical Identity
Dimension: *7(L) × *1(W) × *2(H) mm
Weight: About *0g (with the batteries)