Gas Chromatography By U-THERM INTERNATIONAL (H.K.) LIMITED, China
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs. Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Gas Chromatography

Gas Chromatography

|

Minimum Order

Localité:

-

Prix de commande minimale:

-

Commande minimale:

-

Packaging Detail:

-

Delivery Time:

-

Supplying Ability:

-

Payment Type:

-

Contacter maintenant
Membre gratuit

Personne à contacter Harry

No. 72 Ren Min Road, Yu Hu District, Xiangtan, Hunan

Contacter maintenant

Description

Main features and correlation parameter: 1. The large LCD in Chinese displays the abundance intuitionistic contents, it is very convenient to set parameter. 2. It is adopted with automatic micro-computer controlled spark device. 3. It adopts stable and reliable zeroing, which avoid the unstable situation of baseline caused by potentiometer zeroing. 4. It adopts doubled intelligent automatic cooling system which has the function of frequency conversion and opens the door from the back. Such system makes the operation under the room temperature come true. 5. The column compartment heating up itself in a tracking way particularly which can avoid the pollution to the detector caused by the previous warming up in the column compartment. 6. It is functioned with gas cutting protection and can suggest the user in Chinese, which can protect TCD tungsten filament and chromatographic column from damage. 7. It can diagnose the breakdown by itself, present the reason in Chinese and give an alarm at any moment. 8. Microcomputer controlled, keyboard setting, LCD displaying, on board memory. 9. The capability of the high performance detector and methanator can definitely meet the requirement of ministry of electricity’s gas component determination to transformer. *0. It adopts the system of First injection, Secondary column diversion; such kind system is fast in analyzing and good in reproducibility. *1. Doubled hydrogen flame designed, which can detect the CO, CO2 characterized by low level of hydrocarbons and the high level of hydrocarbons respectively and avoid mutual interference. *2. It adopts late-modeled column filler, doubled column-temperature process which advance the detect time of C2H2, improve the sensitivity and shorten the cycle time Technical parameter and index: 1. Column compartment temperature: with a room temperature from 4 to **0; temperature control accuracy is ±0.1. 2. Testing room temperature: with a room temperature from *6 to **0; temperature

Send a direct inquiry to this supplier

To:

Harry < U-THERM INTERNATIONAL (H.K.) LIMITED >

Je veux savoir: