Vital Signs Monitor CE
Patient Monitor adopts Oscillometry for NIBP measuring,
Photoelectric Oxyhemoglobin Inspection Technology combining
Capacity Pulse Scanning & Recording Technology for SpO2
measuring. Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean
Pressure(MAP), SpO2 and Pulse rate(PR) can be accurately
measured.
Compact appearance, comprehensive functions, simple and convenient
operation, which is applicable for hospitals, community medical
treatment and family.
Features
?Be applicable
for adult, pediatric and neonatal for all-round monitoring, easy
operation and high cost performance.
?Be applicable for medicine, surgery, operating room, ICU/CCU,
emergency room, obstetrics and gynecology, pediatrics.
?Built-in rechargeable Li-polymer battery for uninterrupted
monitoring.
?Compact and flexible appearance, easy for carrying and be suitable
for indoor and outdoor(in ambulance) monitoring.
?With user-friendly interface.
?Display with 2.4`` (**0×**0) color TFT LCD and blue highlight
LED.
?Visual and audible alarm for Systolic Pressure(SYS), Diastolic
Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR), and
upper and lower limit of alarm can be set.
?Unique Flash memory, storage for up to ***0 NIBP data or SpO2 data
within **-hour.
?Convenient and quick in inquiring measurement data.
?Optional parameter: temperature.
Performance
NIBP
monitoring
Measurement method: Oscillometry
Measurement mode: manual/auto/continuous.
Auto measurement interval: adjustable from 1 to **5 minutes.
Resolution: 1mmHg.
Accuracy: Maximum Mean deviation≤±5mmHg, Maximum Standard
deviation≤8mmHg.
Self-check function.
Overpressure protection: double protection for software and
hardware.
Range:
Adult:
Systolic pressure: *0mmHg~**0mmHg
Mean pressure: *0mmHg~**5mmHg
Diastolic Pressure: *0mmHg~**5mmHg
Pediatric:
Systolic pressure:
*0mmHg~**0mmHg
Mean pressure: *0mmHg~**5mmHg
Diastolic Pressure: *0mmHg~**0mmHg
Neonatal:
Systolic pressure:
*0mmHg~**5mmHg
Mean pressure: *0mmHg~**0mmHg
Diastolic Pressure: *0mmHg~**0mmHg
Upper and lower limit of alarm
SpO2
monitoring
?Continuous real-time measuring.
?Adopt digital SpO2 technology, which has strong anti-interference
capability.
?Real-time display SpO2, pulse rate, SpO2 Plethysmogram, bar graph,
SpO2 and Pulse rate(PR) trend graph.
?Trend graph with the function of adaptive scaling
?Standard adult finger-clip probe, binding probe for neonatal is
optional.
SpO2 Measuring
Range: *5%~**0% (Resolution: 1%)
Accuracy: ±2% in stage of *0%***0%, and unspecified in stage of
less than *0%.
Pulse Rate Measuring
Range: *0bpm~**0bpm(Resolution: 1bpm)
Accuracy: ±2bpm or ±2%, whichever is greater.
Measurement Performance in Weak Filling Condition: SpO2 and
pulse rate can be shown
correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the
Pulse rate error is ±2bpm or ±2%, whichever is greater.
Resistance to surrounding light: The deviation between the
value measured in the condition of man-made light or indoor natural
light and that of darkroom is less than ±1%.
Accessories
?A power
cord
?A SpO2 probe
?An adult BP cuff
?An extending tube for blood pressure
Physical characteristic
Dimension: **2(L)×**8(W)×*5(H)mm
Weight: 1.*5kg
Certification documents : Domestic registration, CE