Sell AC Frequency inverter---E1000 series By SoTeng CNC Technology Co., Ltd, China
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs. Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell AC Frequency inverter---E1000 series

Sell AC Frequency inverter---E1000 series

|

Minimum Order

Localité:

Chengdu

Prix de commande minimale:

-

Commande minimale:

1 Piece

Packaging Detail:

carton

Delivery Time:

3-7days

Supplying Ability:

10000 Piece per Year

Payment Type:

T/T

Contacter maintenant
Membre gratuit

Personne à contacter Ms. Angel

linglong, Chengdu, Sichuan

Contacter maintenant

Description

AC Inverter Description:
E***0 series of AC drives is new product. By blocking design, the system function is enriched and built-in EMI filter is optional, advanced EMC design is adopted. The product has the feature of compact in frame, new in shape. E***0 series is a kind of high-quality and multifunction drives that can meet wide-ranging application.

 
 
Items
Contents
Input

Rated Voltage Range

*-phase **0V± *5%; single-phase **0V± *5%
Rated Frequency
*0/*0Hz
Output

Rated Voltage Range

*-phase *****0V; *-phase *****0V
Frequency Range
0.******0.0Hz
Control Mode
Carrier Frequency
2K**0KHz;
Input Frequency Resolution
Digital setting: 0.*1Hz, analog setting: max frequency 0.1%
Control Mode
V/F control
Overload Capacity
**0% rated current, *0 seconds.
Torque Elevating
Auto torque promotion, Manual Torque Promotion 0.1%**0.0%
V/F Curve

4 kinds of modes: beeline type, square type, under-defined V/F curve and auto torque compensation...

DC Braking
DC braking frequency: 1.**5.0 Hz, braking time: 0.***0.0s
Jogging Control

Jogging frequency range: min frequency- max frequency, jogging acceleration/deceleration time: 0.*****0.0s

Auto Circulating Running and multi-stage speed running

Auto circulating running or terminals control can realize **-stage speed running.

Built-in PID adjusting
Easy to realize a system for process closed-loop control
Operation Function
Frequency Setting

Potentiometer or external analog signal (***5V, ****0V, ****0mA); keypad (terminal)↑ /↓ keys, external control logic and automatic circulation setting.

Start/Stop Control
Terminal control, keypad control MODBUS control.
Running Command Channels
3 kinds of channels from keypad panel, control terminal and MODBUS.
Frequency Source

given digit, given analog voltage, given analog current, given pulse frequency, given MODBUS, PID adjusting and stage-speed control.

Accessorial frequency Source

given digit, given analog voltage, given analog current, PID adjusting and stage-speed control.

Optional
Built-in EMI filter, built-in braking unit, tele-control panel
Protection Function

Input out-phase, input under-voltage, DC over-voltage, over-current, over-load, current stall, over-heat, external disturbance

Display

LED nixie tube showing present output frequency, present rotate-speed (rpm), present output current, present output voltage, present linear-velocity, types of faults, and parameters for the system and operation; LED indicators showing the current working status of inverter.

Environment Conditions
Equipment Location

In an indoor location, Prevent exposure from direct sunlight, Free from dust, tangy caustic gases, flammable gases, steam or the salt-contented, etc.

Environment Temperature
**0deg*-**0deg
Environment Humidity
Below *0% (no water-bead coagulation)
Vibration Strength
Below 0.5g (acceleration)
Height above sea level
***0m or below
Applicable Motor
0.*****0KW
 