FOB Price
Obtenir le dernier prix|
Minimum Order
Localit:
-
Prix de commande minimale:
-
Commande minimale:
-
Packaging Detail:
-
Delivery Time:
-
Supplying Ability:
-
Payment Type:
-
SEMA Whitening Accelerator Instruction Manual Welcome to use SEMA Whitening Accelerator! First, please read this instruction manual carefully to obtain its best performance and safety. Please take care of this manual for future consultation. 1. Summary The up-to-date SEMA cool light Whitening Accelerator can convert electric energy into strong blue light. The cool blue light activates the whitening gel and oxidizes the pigment of the teeth through dentin tubes in the shortest time, discoloring the teeth to sparkling white both externally and internally. The **-minute process ensures an improvement of five to fourteen shades. It is not a dream to make your teeth shine with brightness. Nanotechnology makes SEMA Whitening Accelerator both brief and elegant .For dentist, SEMA is imperative; for art, it is graceful. Switching the power on, one only needs 2 seconds to enter the menu, where exists 2 modes. Of these one is for light intensity: low , medium or high ; the other is for curing time: *0s, *0s, 5m, 8m, *0m, *5m, *0m, *5m and *0m . Appropriate time and light can be applied to different individuals for the best performance. “Beepsâ€, marking the switching on of the power, will appear in the whitening process each five minutes. Three beeps indicate the end of the process with the light going off. A press on the ON/OFF button stops the work of SEMA and returns presetting. If any mistake exists, the presetting is capable of being altered during its work. After a beep, the new presetting can be operated. 2. Structure 1. Its in installation, adjustment and maintenance should be conducted by qualified personnel of our company or the country. 2. The power supply should correspond with the specification. 3. Only qualified or authorized personnel can operate the machine. The operator should have professional skills on the medical treatment and take the instruction manual as a reference. 4. Each SEMA Whitening Accelerator consists of: 1. Machine base 2. Taper joint screw 3. SEMA cool light system 4. Vertical pole 5. Connecting pole 6. Iron ball screw 7. Horizontal pole 8. Time 9. Light intensity *0. Switch *1. LCD screen 3. Installation Guide 1. Screw down the vertical pole and the horizontal pole with the iron ball screw. (The horizontal pole can be up and down by loosening or tightening the screw.) 2. Insert the main post screwed with the taper joint into the base until they are firmly connected. 3. Screw down SEMA cool light system with the connecting pole. (The cool light system can be up and down and revolve **0 degree by loosening or tightening the screw.) 4. Plug the electronic cord which theads through the horizontal pole into the socket of the cool light system; plug the other end of the cord which threads through the vertical pole into the socket of the transformer. 4. Specifications Light Source: SEMA LED diode Wavelength: ******0 nm Power Supply: AC**0—**0V *0—*0 Hz 2A H. post: **0cm V. post: **0cm Net Weight: 8Kg 5. Operation Instructions 1. The dentist checks the oral cavity and the surface of the patient’s teeth. Dry his teeth after the patient rinses out. 2. Make sure that the patient is comfortable after putting the mouthpiece inside. Polish the dental dam on the gum with the thickness of **4mm and an extra 0.5 mm extension below the gum .The dentist and the patient put on the eye goggles. Adjust the lamp, vertically to the surface of the patient’s teeth. Switch the power on and preset *0 seconds or *0 seconds for the solidification of the dental dam. Switch the light on the teeth and make sure that the dental dam has been solidified so as to protect the ***** 3. Mix the hydrogen peroxide and the whitening powder into paste. (Only the paste which does not drop off the brush reaches the standard.) Polish the whitening gel (the paste) on *6 or more dry teeth with the thickness of 2 or 3 mm. 4. Adjust the whitening accelerator and choose different modes accordingly. 5. Suppose three “ten-minute†cycles as a period of treatment. 1. Preset the time for the first “ten-minute†cycle. 2. Preset the light intensity. 3. Switch the light on. The machine will stop automatically *0 minutes later and beep 3 times for warning the end of the first cycle .Remove the lamp and suck away the whitening gel. Clean the gel with the cotton rolls if necessary and no washing is needed then. 6. Repeat stage 5 twice to carry on the second and the third cycles. 7. Remove the dental dam, the mouthpiece and the eye goggles. The patient rinses the mouth out. 6. Caution 1. The following oral sufferers are discouraged from undergoing this treatment: A. one with injuries of the oral cavity B. one having broken teeth or lack of some teeth C. one having uncrowned or defective dental plate incisors D. one suffering from periodontal diseases E. one with serious dental calculus 2. Keep away from colored drinks and food for 2 or 3 days after the treatment. Avoid cold or hot drinks for the first *4 hours if there is any tooth sensitivity. 3. It is suggested that every period of treatment be divided into 3 phases for its best performance. (*0 minutes per treatment is available.) 4. If the patient feel ache or has comfortlessness caused by the treatment or the medicine, the ache will disappear in one or two days. 7. Maintenance 1. Unplug the power cord if you are not going to use it. 2. Avoid the machine falling to the ground. 3. Don’t use the machine in high environmental temperature. 4. Don’t dismantle the machine; contact the manufacturer or the dealer if there is any problem. 8. Pointer for Transportation and Storage 1. The environmental temperature range : **0℃ - **0℃ 2. The relative humidity range ≤*0% 3. The atmospheric pressure: **0—***0 hpa 4. Handle with care. 9. Sterilization The lamp can be sterilized with alcohol. *0. What’s included QTY. ITEM 1 SEMA Cool Light System 1 Main Post 1 Transformer 1 Machine Base 1 Instruction Manual 1 Mouthguard 1 Teeth Whitening Kit *1. After Service We pledge our product of the best quality, at the same time you will enjoy our free-of -charge after service. In half a year from the date of purchase , if the machine has any damage caused by manufacturing technology or raw and processed materials , you change the old machine for a new one ; in one year from the date of purchase , we will offer free charge service for you ; over a year , we will charge the maintenance fee .If by any chance , the machine is fallen , dismantled or improperly operated , it cannot enjoy the free maintenance .