DT862 three phase energy meter, kwh meter By yueqing xiankai electrical co.,ltd, China
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs.
Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
DT862 three phase energy meter, kwh meter

DT862 three phase energy meter, kwh meter

|

Minimum Order

Localité:

wenzhou city

Prix de commande minimale:

-

Commande minimale:

-

Packaging Detail:

-

Delivery Time:

one week

Supplying Ability:

50, 000 pieces

Payment Type:

-

Contacter maintenant
Membre gratuit

Personne à contacter Mr. Ms. Hittey

jinlu Industrial Zone beibaixing, yueqing, zhejiang/china

Contacter maintenant

Description

Detailed Selling Lead Description General: The DT**2 three-phase four-wire meter is designed to meet the latest IEC****1 standards for measuring active energy in three-phase four-wire alternating current power grids. Connection is direct or by instrument transformers. It has an average service life of *0 years and maximum overload capacity of **0% Ib. Features: 1. Meter case: it meets the protection requirements set by protection class IP*3 of IEC****9 2. Terminals and terminal block a. Terminals: the connection terminals are made of nickel-plated brass with features of high mechanical strength, good conductivity and corrosion-resistance b. Terminal block: the terminal block is injection molded of heat- and fire-resistant bakelite 3. Rotor: the rotor shaft is turned of high strength aluminum alloy Technical data: 1. Meter type: DT**2 2. Standards: IEC****1, IEC**4 3. Accuracy (according to IEC****1) a. Transformer operated: class 1 b. Direct connected: class 2 4. Average service life *0 years 5. Rating current of transformer in 5A direct connection 6. Reference voltage (Un): 3 x *7. 7/**0V, 3 x **0/**0V, 3 x **0/**0V 7. Reference frequency: *0Hz, *0Hz 8. Non-running with no-load: 0.9~1.1Un 9. Starting current: 0.4%Ib, 0.5%Ib *0. Mean temperature coefficient: from 0.1Ib to Imax at unity PF; from 0.2Ib to Imax at unity 0.5 lagging < 0.*8%/°C < 0.*2%/°C *1. Insulation level: withstand AC voltage for *0Hz, 1min withstand impulse voltage 1.2/*0us > 2kV *2. Basic current (maximum current) A: 1.5(6), 3(6), 5(*0), 5(*0), *0(*0), *5(*0), *0(*0)

Send a direct inquiry to this supplier

To:

Mr. Ms. Hittey < yueqing xiankai electrical co.,ltd >

Je veux savoir: