Switchgear, Combined AC Metal-Clad Switchgear By Ningbo Ville Enterprise Co., Ltd., China
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs.
Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Switchgear, Combined AC Metal-Clad Switchgear

Switchgear, Combined AC Metal-Clad Switchgear

|

Minimum Order

Localité:

-

Prix de commande minimale:

-

Commande minimale:

-

Packaging Detail:

-

Delivery Time:

-

Supplying Ability:

-

Payment Type:

-

Contacter maintenant
Membre gratuit

Personne à contacter Ms. Sophie

Qingshuiqiao, Ningbo, Zhejiang

Contacter maintenant

Description

General: XGN*6A**2 Combined and Fixed Indoor AC Metal-clad switchgear is a new generation of HV electric whole set products, which is complied with national standard GB***6 [***5kV AC Metal-clad Switchgear] and the specification of DL**4 [Ordering technical condition of Indoor AC HV Switchgear] issued by Minister of Electricity Power as well as IEC **8 [From 1kV to *2 kV AC Metal-clad Switchgear and Control equipment]. And it has the closedown function of "Five production" put forward by Dept 2. This switchgear is suitable for three-phase AC *0HZ, ***0kV single sectioning busbar system used to distribute electric power. It has the function of controlling, monitoring and protecting circuit. And it is wildly used in varieties of power plants, substation, industrial and mining enterprise and high rise buildings as well as combined with RMU to be applied in the switching stations. Product feature: A. Fitted in integer type vacuum circuit breaker, such as *2kV ***0A and *0kA; B. A kind of specified designed switchgear in order to reduce occupied area of substation; C. May combined with RMU randomly; D. Simple but reliable machinery interlock for false protecting operation and easy operation; E. The functional units are separated and fitted in separate pressure release passage to protect the malfunction from enlarging and expanding; F. Isolating distance and cable terminal contacts can be watched through the view window. Ordering notice: Please provide the followings A. Main wiring scheme code and single wire system diagram, pareto diagram and layout plan; B. Secondary principle diagram, terminal pareto diagram. If not terminal pareto diagram, up to manufacturer&#**9;s standard; C. Type, specification and quantity of electric components of switchgear; D. Summary table of electric apparatus; E. Please provide span and height dimensions if busbar bridge is needed ( between two switchgears or between switchgear and wall); F. Please indicate if s

Send a direct inquiry to this supplier

To:

Ms. Sophie < Ningbo Ville Enterprise Co., Ltd. >

Je veux savoir: