Sell Cu/XLPE/STA/PE Power Cable(insulated cable, High voltage cable) By XINGLE GROUP CO., LTD, China
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs.
Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell Cu/XLPE/STA/PE Power Cable(insulated cable, High voltage cable)

Sell Cu/XLPE/STA/PE Power Cable(insulated cable, High voltage cable)

|

Minimum Order

Localité:

-

Prix de commande minimale:

-

Commande minimale:

-

Packaging Detail:

-

Delivery Time:

-

Supplying Ability:

-

Payment Type:

-

Contacter maintenant
Membre gratuit

Personne à contacter Ms. ivy

No.17 Changsheng road, Yueqing, Zhejiang

Contacter maintenant

Description

Cu Conductor XLPE Insulated Steel tape armored PE Sheathed Power Cable Executive Standard: It is manufacture under GB/T*********2 standard(The same as IEC****2). Application: It is used to transmit and distribute power in power transmission and distribution system of *5kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable. Using features: 1. Rated voltage: Uo/U: *6/*5kV, *1/*5kV, *2/*0 kV (*4 kV), 8.7/*0kV, 8.7/*5kV, 6/6kV, 6/*0kV 2. No. of core: Single-core, Three-core 3. The highest allowed operating temperature of conductor for long-term working is *0oC. In short-circuit (Max. long-term is no more than 5 seconds). The highest temperature for conductor is no more than **0oC. 4. ***** resistance of the conductor complies with the stipulations of GB/T********7. 5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated. 6. The cable is laid without horizontal drop limit. 7. Working Frequency Voltage Test: For cable with Uo of 3.6kV or lower: 2.5Uo*2kV/5min without puncture. For cable with Uo of 3.6Kv~*8kV: 3.5Uo/5min without puncture. For cable with Uo of *1kV and *6 kV: 2.5Uo/*0min without puncture. 8. Partial Discharge Test: The discharge volume should be no more than *0pC under 1.*3Uo for the cable. Note: The single core armoured cables are used for ***** system only. If used for ***** system, the magnetic isolation should be applied on the steel armoire wires of non-magnetical materials should be used. (cable, power cable, power wire, electric cable, electrical cable, xlpe insulated cable, xlpe insulated power cable, pvc cable, pvc power cable, xlpe cable, xlpe power cable, pe sheathed cable, pe sheathed power cable)

Send a direct inquiry to this supplier

To:

Ms. ivy < XINGLE GROUP CO., LTD >

Je veux savoir: