Measurement range
Â
- Frequency Range: 0.3 to ***0MHz
- Impedance: *0Ω (*5Ω)
- Test Port Connectors: N-type Female
- Number of Test Ports: 2
- Frequency Accuracy: ±5 ppm
- Frequency Resolution: 1 MHz
- Number of Test Points User-Selectable: 2 to ****1
- IF bandwidth settings 1/1.5/2/3/5/7/*0 step: 1Hz to *0 kHz
- Dynamic Range IF Bandwidth *0Hz: 2 to ***0MHz > **5dBTyp.
**0dB
Â
Test port output
Â
- Power range: **5 to **0dBm
- Power accuracy : <1.0dB
- Power resolution: 0.*5dB
- Harmonic distortion: **0dBc
Â
Test port
Â
- Match Without system error correction: > *5dB
- Damage level: **6dBm
- Damage DC voltage: *5V
Â
External Reference Signal Input/Output
Â
- Frequency: *0MHz
Â
Measurement Accuracy
Â
1. Accuracy of Transmission Measurement (magnitude/phase)
Â
- Specifications are based on a matched DUT, a measurement
bandwidth of 1 Hz,
and a nominal source power of *5dBm **5 to *5dB 0.2dB/2.0°
Â
*5 to **0dB 0.1dB/1.0° , **0 to **0dB 0.2dB/2.0° , **0 to **0dB
1.0dB/6.0°
Â
2. Accuracy of Reflection Measurement (magnitude/phase)
Â
- Specifications are based on a matched DUT, a measurement
bandwidth of 1 Hz, and a nominal source power of *5dBm
Â
0 to **5dB 0.4dB/4.0° , **5 to **5dB 1.5dB/7.0° , **5 to **5dB
4dB/*2.0°
Trace Stability
Â
Temperature DependencePer one degree of the temperature variation :
0.*2dB
Trace Noise MagnitudeIF bandwidth 3kHz : 0.**1dB rms
Â
Other capabilities
Â
1. Internal hard disk drive
Store and recall instrument states, calibration data, and trace
data on internal hard drive. Trace data can be saved in CSV (comma
separated value) format. Instrument states include all control
settings, limit lines, segment sweep tables, and memory trace
data.
Â
2. USB
Instrument states, calibration data, and trace data can be stored
on an external USB drive.
Â
3. Screen hardcopy
Printouts of instrument data are directly produced on a printer.
The analyzer provides USB and parallel interfaces.
Â
4. Familiar graphic user interface
Protek A**3 provides graphic user interface based on Windows. There
are three ways to operate A**3 manually: a hard-key interface, a
touch screen interface, mouse interface.
Â
5. Limit lines
Defining the test limit lines that appear on the display for
pass/fail testing. Defined limits may be of any combination of
horizontal/sloping lines and discrete data points.
Â
Programming functions
Â
COM/DCOM Automation
Â
Remote Control
LAN, GPIB (optional)
Operating environment
Â
Temperature: *5 to **0°c
Dimension (W x H x D): **6 x **2 x **0 mm
Weight: *0.6 kg
Power supply: **0 to **0 VAC / *7 to *3 Hz  Â