Features
Â
•    Can be used for all standards of sterile burette type infusion set for single use
 Â
•    Automatic Calibration for IV sets.
•    Five working modes: Rate mode, Time mode, Volumetric mode, Dose mode and Drug library mode.
•    Built in rechargeable battery (Lithium-ion polymer battery).
•    Spec of the fuse: F1AL/**0V, two (inside).
•    8 hours internal battery backup.
•    Alarm functions: occlusion, empty bottle, low battery, rate error, end of infusion, door open, air in line etc
•    Three levels of the occlusion limited pressure: high, middle and low.Â
•    Three levels of alarm sound: high, middle and low.Â
•    The infusion pump goes into KVO mode automatically as infusion is completed.
•    Purge and Bolus functions
•    Anti-bolus function
•    History records being demanded directly. And with RS**2 ports as well, in order to connect other equipments.Â
•    Waterproof class: IPX4Â
Technical Specification
•    Flow range : 1.0~*9.9ml/h, 0.1ml/h increment                                        Â
**0~***0ml/h, 1ml/h increment
               or 1~**0drops/min, 1 drop/min increment.
•    Flow precision : ± 5%Â
•    Target volume (TAR VOL): 0.1~*9.9ml, 0.1 ml increment; **0~***9 ml, 1ml increment.
•    Infusion time (TIME): 1min~***0min, increment 1min.
•    Adjustable range of infusion precision:**0%~**0%, increment:1% (for volumetric mode).Â
•    Infused Volume range: 0.1~*9.9ml increment 0.1ml; **0~***9ml, 1ml increment.
•    Adjustable ranges of Sol. Vol, Drug Mass, Dose:
Sol. Vol (solution Volume): 1~***9 ml, increment: 1ml
Drug Mass: 0.1~**9.9, increment: 0.1, Unit: g, mg, U, IU;
Dose: 0.**1~9.**9, increment: 0.**1; *0.*0~*9.*9, increment: 0.*1;
**0.0~**9.9, increment 0.1;***0~***9, increment 1;
Dose units: ng/kg/min; ug/kg/min; mg/kg/min; g/kg/min; Ug/kg/h; mg/kg/h; g/kg/h;
ug/min;Â mg/min;Â g/min;Â ug/h;Â mg/h;Â g/h;Â U/min;Â U/h;Â IU/h;Â U/kg/h;Â mg/kg;Â ml/min;Â ml/h;
Body Weight range: 0.1~**0.0kg, increment: 0.1kg
•    Purge: **0 ml/h.
•    Bolus : Adjustable from 1~***0ml/h, in steps of 0.1ml/h (if flow rate  **0ml/h),Target Volume:1~**0 ml, in steps of 1ml
•    KVO rate: if the flow rate ≤*0 ml/h, KVO is 1ml/h.
Otherwise KVO is 3ml/h.
•    Power supply: AC**0~**0V, *0/*0Hz, Internal Lithium-ion polymer battery: DC *1.1V,  ≥***0mAh. The battery backup is approx. 8 hours (when using a fully charged battery and running at *0drops/min with any standard IV Set).
•    Power consumption:≤*5VA
•    Class: I
•    Type    : CFÂ
•    Size: **5mm(W)×**0mm(H)×**5mm(D)
•    Net weight: approx. 2kg
•    Operating condition:Â
Ambient temperature: 5~*0 degree C,Â
Relative humidity: *0~*0%
•    Storage condition:
Ambient temperature: **0~*5 degree C
 Relative humidity   : *0~*0%.
Â