La description
1.ISO****5,CE,FDA
2. **-hour blood pressure data recording.
3.Indicating range:0~**0 mmHg
4.Wireless infrared data transfer
CB*****-B Ambulatory BP Monitor
�
SPECIFICATIONS�
����������������������������������
Duration of
blood pressure monitoring:
|
*4
hours
|
Method of
measurement:
|
Osillometric
�method
|
Storage
medium:
|
Flash
memory
|
Memory
capacity:
|
**6
measurements
|
Indicating
range:
|
0~**0mmHg
|
Range if
blood pressure:
|
Systolic
*0~**0 mmHg
|
Diastolic
*0~**0 mmHg
|
Pressure
precision:
|
3mmHg
|
Range of
pulse:
|
*0~**5
bpm
|
Communication
port:
|
Wireless
infrared data transfer
|
Batteries:
|
4�AA size
alkaline batteries
|
Dimensions:
|
**4�*8�*1(mm3)
|
Weight:
|
**5g
(excluding
batteries)
|
Figure titles
1.���Reviewable
artery pulsation waveform & tabulated numerical data
results
2.���Blood
pressure frequency histograms
3.���Blood
pressure & pulse rate trends
�
�
�
Reviewable analysis techniques
to obtain BP measurement
�
Artifact is unavoidable in ABP
testing. Fortunately, there is a way to eliminate artifact, which
is by utilizing the approach to ABPM analysis. Without utilizing
advanced technology, physicians have to interpret tabulated
numerical data. Determining valid data from artifact can be
difficult to distinguish. Unfortunately, traditional ABPM systems
use technology that cannot properly distinguish artifact from
true wave-form. However, Our monitor validates each measurement
readings completely transparent, and its real-time testing is
combined with review analysis. Physicians can determine instantly
whether the data is true or false according to the original
artery pulsation waveform. Our ABPM effectively screens errors
and detects artifact, thus determining real blood pressure
statistics to ensure an effective credible report.
�
Versatility and
durability
�
rewards you in the long run Highly
integrated design saves space and ultimately improves the
performance and reliability, adding to the recorder's durability
and impact and shock-resistance. Specially-designed pressure
security system will not allow overpressure or air deflation
failure. Automatically monitors battery life and automatically
stopping in the event of voltage insufficiency. Patient account
information can be loaded into the recorder in advance avoiding
possible mistakes, an appealing feature for multiple recorder
facilities. our presents products with infinite upgrading
potential, thus ensuring future software and hardware upgrading
at inimum cost.
�
Widen dynamic range
�
The degree of the artery pulsation
signals differs greatly in patients. The strongest signal may be
more than *0 times that of the weakest. This is a main reason
that can cause failure with virtually all automatic testing of
blood pressure. Our introduction of advanced AGC
(auto-gain-control) technology and components with a large
dynamic range, which automatically adjusts to the variation of
the patients' pulsation signal range.
�
Highly intellectualized airflow
control
�
For correct blood pressure
analysis, a system must take in account that the pressure of the
inflated cuff on the designated site be slightly higher than the
systolic blood pressure. The self-fluctuation of the human
body's BP makes practical systolic blood pressure value
relatively hard to accurately estimate. The traditional testing
method offered one-time detection of systolic blood pressure
using ****0mmHg as a standard for the inflated component.
However, this method has two obvious deficiencies: overpressure
on the inflated object and long inflation time. These two
deficiencies make it difficult to achieve accurate results while
also being uncomfortable on patients. The result of BP
fluctuation and the inaccuracies of former systolic blood
pressure systems are common due to flawed techniques used to
obtain systolic blood pressure.Eventually such methods fail and
then re-inflation incurs to re-test. our ABPM automatically
identifies the artery pulsation during the inflation process,
inflating while pre-measuring, so it inflates to the proper
pressure. The unique function of automatic air inflation
maximizes at *0mmHg, accurately compensating any sudden increase
of blood pressure. The other important factor that influences the
accuracy of BP testing is the deflation speed. Improper inflation
and deflation speeds produce in-accuracy. The more rapid the
deflation, the less accurate are the results. If the deflation
speed is too slow, the testing time will be prolonged, thus the
patient can experience significant discomfort which can affect
the results due to the increased stimulus. The traditional BP
devices utilizes mechanical non-linear deflation components,
while deflation speed is permanently set without adjustability,
this effects the inflation and deflation speed, especially for
obese patients or patients with larger appendages (it is common
for testing to be extended in these circumstances adding minutes
to the analysis, again causing additional discomfort). For
patients with smaller appendages the deflation speed is often too
fast (it is common in these circumstances for the deflation
process to be under *0 seconds, this method produces obvious
in-accurate results). our technology, integrates multiple control
techniques, liquid control and pattern recognition during the
analysis processing, thus extruding accurate results. our ABPM
introduces precise digital valve and advanced digital speed
control technology to identify linear smooth deflation. This
technology intellectually identifies the arm size and the blood
pressure of the patient. The deflation speed is constantly
controlled on any patient, so the accuracy is
increased significantly during the linear speed deflation
process. The process completely imitates the auscultation process
of physicians, achieving accurate results from the data gathering
process.
�
Quick and accurate analyzing
system
�
Highly integrated design saves
space and ultimately improves the performance and reliability,
adding to the recorder's urability and impact and
shock-resistance. Specially-designed pressure security system
will not allow overpressure or air deflation failure.
Automatically monitors battery life and automatically stopping in
the event of voltage insufficiency.
Patient account information can be loaded into the recorder in
advance avoiding possible mistakes, an appealing feature for
multiple recorder facilities. our presents products with infinite
upgrading potential, thus ensuring future software and hardware
upgrading at minimum cost.
�
The limitation in the
traditional ABPM
Ambulatory Blood Pressure Monitor
(ABPM) has been widely used in clinic diagnosis. The accuracy of
measuring result of Ambulatory Blood Pressure (ABP) is the most
important. The influence of accuracy in measuring result has two
primary factors: one is the accuracy of the recorder itself and
the other one is the condition during every testing, it means
artifact factor. The measuring accuracy of recorder itself is
responsible for the manufacturer and it could be distinguished
through some method. For example, it is very easy to compare with
mercury sphygmomanometer. But the artifact is unable vanish
thoroughly. ABP testing is much different with clinic blood
pressure testing that we can�t control the condition during
every testing, and we also can�t distinguish the artifact. It
is the only way to emphasize the patient that they should keep
unmovable and relax their cuffed arm from inflating until
deflated all over, and to emphasize the patient should avoid
oppress the cuff during sleeping to reduce the artifact and the
invalid readings as far as possible.
The readings list is the most important and the indispensable
part in an ABPM report, even though the varied formats of the
report from different brand. The accuracy of the ABPM report is
totally based on the accuracy of every line in this readings
list. Any statistics graph or table in the report comes from
these data.
Due to the traditional ABPM just record the numeric readings
only, when the artifact and error measurement was happened, it is
difficult for doctor to confirm whether the readings are right or
wrong in a series of data. How the doctors could do when they
face to the list? Any edit is un-objectivity and comes from them
�feeling so�. It is also existence a big flaw in almost all
other brands of ABPM.
In what way to distinguish the invalid examination and reject
thereby enhance the accuracy of the final report? That is the
technology of ambulatory blood pressure test with artery
pulsation w
Pays: |
China |
N ° de modèle: |
CB-1804-B
|
Prix FOB: |
(Negotiable)
Obtenir le dernier prix
|
Localité: |
China |
Prix de commande minimale: |
- |
Commande minimale: |
1 Set |
Packaging Detail: |
carton |
Heure de livraison: |
3-5 dats after payment |
Capacité de Fournir: |
600 Set per Month |
Payment Type: |
Western Union, T/T |
Groupe de produits : |
- |