ULP-8040, ULP-4040 Reverse Osmosis Membrane Element with ISO9001 By KeenSen Technology Co., Ltd,
Pas encore membre de TradeKey.com? Inscrivez-vous pour vous connecter avec 9 millions d'importateurs et exportateurs. Rejoignez-le maintenant c'est gratuit |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
ULP-8040, ULP-4040 Reverse Osmosis Membrane Element  with ISO9001 ULP-8040, ULP-4040 Reverse Osmosis Membrane Element  with ISO9001 ULP-8040, ULP-4040 Reverse Osmosis Membrane Element  with ISO9001
Next

ULP-8040, ULP-4040 Reverse Osmosis Membrane Element with ISO9001

62 ~ 410 / Unit ( Negotiable )

|

1 Piece Minimum Order

Pays:

China

N ° de modèle:

ULP-8040, ULP-4040

Prix FOB:

62 ~ 410 / Unit ( Negotiable ) Obtenir le dernier prix

Localité:

-

Prix de commande minimale:

62 per Unit

Commande minimale:

1 Piece

Packaging Detail:

Fresh membrane + Carton

Heure de livraison:

Within 3 days

Capacité de Fournir:

8000 Piece per Month

Payment Type:

-

Groupe de produits :

Contacter maintenant
Membre gratuit

Personne à contacter Sally

No. 6, Lutian RD, Lu Valley, Changsha, Hunan

Contacter maintenant

Spécification du produit

  • Delivery Time:Within 3 Days
  • Type:Dry/Wet membrane

La description

KeenSen ULP****0, ULP****0 Membrane Elements are mainly applicable to Brackish water with low pressure system.
 
Model Active Membrane Area(ft2(m2) Operating Pressure psi(MPa) Permeate Flow
 GPD(m3/d)
Stabilized Salt Rejection (%) Min. Salt Rejection (%)
ULP****0 **0(*7.2) **5(1.*5) ****0(*9.7) *9.2 *8.5
ULP****0 *8(7.2) **5(1.*5) ***0(8.3) *9.2 *8.5

 
Test Condition
Temperature of Testing Solution:*5 °C
Concentration of Testing Solution (NaCl):1,**0ppm
PH Value of Testing Solution: 7.**8
Recovery Rate of Single Membrane Element:*5%
Extreme Operation Conditions
Max. Working Pressure: **0psi (4.*4Mpa)
Max. Feedwater Temperature: *5°C
Max. Feedwater SDI: 5.0
Free Chlorine Concentration of Feedwater: 0.1mg/L
pH Range of Feedwater during Continuous Operation: 3~*0
pH Range of Feedwater during Chemical Cleaning: 2~*2
Max. Pressure Drop of Single Membrane Element: *0psi (0.*7Mpa)

The Application Scope
1. The ULP membrane is mainly applied to the salt rejection of low-salt water.
2. The standard operating pressure is 1.*5 MPa. In actual application, operating pressure is affected by the density of water quality and the rate of system recovery etc.

Pays: China
N ° de modèle: ULP-8040, ULP-4040
Prix FOB: 62 ~ 410 / Unit ( Negotiable ) Obtenir le dernier prix
Localité: -
Prix de commande minimale: 62 per Unit
Commande minimale: 1 Piece
Packaging Detail: Fresh membrane + Carton
Heure de livraison: Within 3 days
Capacité de Fournir: 8000 Piece per Month
Payment Type: -
Groupe de produits : RO Membrane Element

Send a direct inquiry to this supplier

To:

Sally < KeenSen Technology Co., Ltd >

Je veux savoir: