Prix FOB
Obtenir le dernier prix|
- Minimum Order
Pays:
China
N ° de modèle:
-
Prix FOB:
Localité:
-
Prix de commande minimale:
-
Commande minimale:
-
Packaging Detail:
-
Heure de livraison:
-
Capacité de Fournir:
-
Payment Type:
-
Groupe de produits :
-
Personne àcontacter eric
Road caiwei 8, Beijing, Beijing
Application
   High voltage technology
Â
   Main characteristics
   Gas
Density Controller for SF6 and other gases
   Principle:     Â
Reference gas measurement
   Measuring range: 0...1 MPa (0...1000 kPa)
  Â
Output:Â Â Â Â Â Â Â Â
 floating change-over contact
   Switch point:   adjustment in
factory
Â
   Main features
   Exact
switching following isochore
?  Excellent vibration resistance
? No false alarms at low temperatures
? Stainless steel sensor
? Independent, galvanically separated circuits
Â
   Ordering information
Â
   Specifications
Â
   Main characteristics
  Â
Principle:Â Â Â Â Â Â R eference gas
measurement
   Measuring range: 0...1 MPa (0...1000 kPa)
  Â
Output:Â Â Â Â Â Â Â Â
 floating change-over contact
   Switch point:   adjustment in
factory
Â
    Accuracy (@********************
   Switching differential typ.
     Microswitch 20: < 15 kPa
     Microswitch 28/83: < 10 kPa
   Accuracy of the reference Miroswitch from the
reference isochore (see page 4)
     -30...+50°C: < 10 kPa(Filling
pressure: < 650 kPa)
     -30...+50°C: < 12 kPa(Filling
pressure: < 1 MPa)
   Microswitch
  Â
Rating:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â
see table
   Resistance of insulation: > 2 MΩ
   Dielectric
strength:Â Â Â Â Â 2 kV terminal ground
   Life time (mechanical)
     Microswitch
20:Â Â Â Â Â Â Â Â 1 Mio.
cycles
     Microswitch
28/83:Â Â Â Â Â 10 Mio. cycles
   Max. difference from the lowest to the
highest
     switching
point:Â Â Â Â Â Â Â 130kPa
Â
   Electrical connection
   Male electrical plug:   Â
DIN 43650-A
   Female electrical connector
      Cable-:              Â
6...13 mm
     Terminal
screw:Â Â Â Â Â Â Â Â 0.5...1.5
mm2
Â
   Environmental conditions
   Ambient
temperatur:      -40....+80°C
   Media
temperature       Â
-40....+80°C
   Protection:
    Â
8711/50/51:Â Â Â Â Â Â Â Â Â Â Â Â
IP54
    Â
8712/21/31/41:Â Â Â Â Â Â Â Â Â
IP00
  Â
Humidity:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â
max. 95 % relative
   Vibration
     Min. Difference from switch point: 5
kPa
     20...80
Hz:Â Â Â Â Â Â Â Â Â Â Â Â
4 g
  Â
Shock:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â
50g/ 11ms
Â
   Security
   Leakage of Reference chamber: < 0.5 kPa/
year
                                Â
(5·10-10 kPa·I·s-1)
  Â
Service:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â
none,switch point checking after 5 years
   Reference chamber leakage tests: With Helium gas
in vacuum process
                                Â
and integral leakage test in overpressure process
Â
Â
   Mechanical
data
   Material
     Sensor:
       Â
Housing:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â
1.4435 (AISI316L)
       Â
Filling:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â
Gas
    Â
Housing:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â
AlMgSi1, anodized
     Male electrical
plug:Â Â Â Â Â Â PA, Polyamid
  Â
Weight:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â
 ~ 350 g (8711)
Â
   Electrical data switch
   Electrical connection
  Â
Dimensions
  Â
Accessories
Pays: | China |
N ° de modèle: | - |
Prix FOB: | Obtenir le dernier prix |
Localité: | - |
Prix de commande minimale: | - |
Commande minimale: | - |
Packaging Detail: | - |
Heure de livraison: | - |
Capacité de Fournir: | - |
Payment Type: | - |
Groupe de produits : | - |