Prix FOB
Obtenir le dernier prix|
1 Piece Minimum Order
Pays:
China
N ° de modèle:
YL-8N
Prix FOB:
Localité:
CHINA
Prix de commande minimale:
-
Commande minimale:
1 Piece
Packaging Detail:
Carton
Heure de livraison:
3~7 days
Capacité de Fournir:
1000 Piece per Month
Payment Type:
L/C, T/T
Groupe de produits :
Personne à contacter Mr. Shiwei
2nd Floor No. 11, Dongxiao Road, Shantou, Guangdong
1.External Dimension
(L×W×H)
|
YL*8NA(*6mmX*6mmX**5mm) YL*8NB(*8mmX*6mmX**5mm)
YL*8ND(*2mmX*2mmX**5mm) YL*8NE(*8mmX*8mmX**5mm)
|
2.Setting accuracy
|
±0.5% FS±1 during the whole measuring
range
|
3.Measure precision
|
±0.2% FS±1.
|
4.Sample frequency
|
2 times/sec.
|
5.The s(standard signals,
free to combine)
|
K,K1,J,E,E1,S,N,T,B,R,Wer,Pt**0,Cu*0,**5V,**5V,***0mA,***0mA
and ***0mA.
|
6.The ways of control temperature
|
((1) Intelligent setting: factory Initial
setting P,I,D.
But when the
temperature is fluctuating around the critical point,the
value of P,I and D can be adjusted.
(2)Time proportional controlling: modify I=0,
D=0, P stay unchanged.
(3)Reach-stop controlling: modify P=0, I and
D stay unchanged.
(4)Upper-lower limit controlling: modify P=0,
and set HY as what you need to control the
section.
|
7.Output
(selective)
|
” I” for Impulse output ***0mA and
***0m;
"U" for Voltage output **5 VDC and
**5VDC;
YL*8NAI / YL*8NAU ( *6 X *6 X
**5mm)
YL*8NBI / YL*8NBU (*8 X *6 X
**5mm)
YL*8NDI / YL*8NDU (*2 X *2 X
**5mm)
YL*8NEI / YL*8NEU (*8 X *8 X
**5mm)
“S” for Impulse voltage *2VDC.
“R" for Relay controlling AC contactor(standard voltage AC*2V)
YL*8NAS / YL*8NAR ( *6 X *6 X
**5mm)
YL*8NBS / YL*8NBR (*8 X *6 X
**5mm)
YL*8NDS / YL*8NDR (*2 X *2 X
**5mm)
YL*8NES / YL*8NER (*8 X *8 X
**5mm)
|
8.Relay contact load
|
**0VAC/3A (not conductable), **0VAC/1A (conductable,CosΦ=0.4).
|
9.Impulse voltage load
|
*2VDC, max=*0mA (impulse SSR, with protection
of short circuit)
|
*0.Analog voltage and current
load
|
( standard) **5VDC, ***0mA, loading
resistance Max=**0Ω
|
*1.Alarm function
|
*2 kinds of alarm of deviation value for upper and lower limit,
the absolute value of alarming funtion for upper and lower limit is free to combine.
|
*2.Alarming output load
|
Relay contact **0VAC/3A (not conductible), **0VAC/1A (conductable,
CosΦ=0.4).
|
*3. Voltage consumption
|
*****0VAC,****0Hz,≤5W
|
.Insulating resistance
|
Pays: | China |
N ° de modèle: | YL-8N |
Prix FOB: | Obtenir le dernier prix |
Localité: | CHINA |
Prix de commande minimale: | - |
Commande minimale: | 1 Piece |
Packaging Detail: | Carton |
Heure de livraison: | 3~7 days |
Capacité de Fournir: | 1000 Piece per Month |
Payment Type: | L/C, T/T |
Groupe de produits : | Multistage slopes temperature controller |